Manualios.com

Barker SPLIT AIR-CONDITIONER Owner's Manual

Barker SPLIT AIR-CONDITIONER Manual Online:

4.2, 583 votes
Barker SPLIT AIR-CONDITIONER User Manual
Barker SPLIT AIR-CONDITIONER User Guide
Barker SPLIT AIR-CONDITIONER Online Manual

Text of Barker SPLIT AIR-CONDITIONER User Guide:

  • Barker SPLIT AIR-CONDITIONER, All heat pumps sold in stores may not be returned before it was inspected on site by a certified technician of Les Entreprises CR Inc. Only certified technicians from Les Entreprises Cr Inc., are authorized to repair or exchange a defective heat pump under warranty. The warranty covers all parts and labor for 1 (one) year from the date of purchase and 5 (five) years on the compressor itself excluding labor. The warranty is effective from the date of purchase, not the date of installation. The warranty fully applies even if you have installed the heat pump by yourself. Warranty and Service appl

  • Barker SPLIT AIR-CONDITIONER, SPLIT AIR-CONDITIONER OWNER’S MANUAL Thank you for selecting our high quality Air Conditioner. To ensure satisfactory operation for many years to come, this Owner’s Manual should be read carefully before using air conditioner. After reading, store it in a safe place. Please refer to the manual for questions on use or in the event that any irregularities occur. This Air Conditioner should be used for household use only. WWW.BARKER04.COM INSTALLATION VIDEO For warranty and service, call us at : Tel. : 1-819-538-0011

  • Barker SPLIT AIR-CONDITIONER, 1 SAFETY PRECAUTIONS................................................................................................. 2 SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER..................... 8 INSTALLATION MANUAL............................................................................................ 10 OPERATION MANUAL.................................................................................................. 19 REMOTE CONTROLLER............................................................................................. 20 FAN SPEED AND AIR DIRECTION ADJUSTMENT...............................

  • 12 INSTALLATION MANUAL – Installation of the outdoor unit INSTALLATION MANUAL – Installation of the Indoor unit 6 inches (15.3 cm) Minimum space back The condensed water and the ice formed in the outdoor unit during heating operation will leak on the ground. Never install the outdoor unit directly on the ground. Always have a minimum clarance of 8 inches under the unit and the groun

  • Barker SPLIT AIR-CONDITIONER, 15 INSTALLATION & REPAIR GUIDE 1 - The outdoor valve for gas leaking must be removed prior to connect the indoor male coupler. 2 - Press firmly the projecting section backward to free the outdoor valve for gas leaking. 3 - Once removed, you can discard the outdoor valve for gas leaking.

  • Barker SPLIT AIR-CONDITIONER, 21 FAN SPEED AND AIR DIRECTION ADJUSTMENT Select the fan speed and air direction. Please use remote controller to adjust the up-down air direction. Do not adjust the up-down louver with the hand to avoid damage. The advised range of the up-down direction When the louvers are in position, the unit can be use in cooling or drying mode. Position to are for heating mode.

  • Barker SPLIT AIR-CONDITIONER, 17 Use 2/12 AWG electrical wire with 20 amp circuit breaker for the 12000 BTU ET 18000 BTU. 12000 BTU = 120 volts 18000 BTU = 220 volts AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 INSTALLATION & REPAIR GUIDE WIRING SPECIFICATIONS MODEL capacity (Btu/h) Power wiring Connection wiring N L G

  • Barker SPLIT AIR-CONDITIONER, NEVER USE insulation foam to seal the hole. ALWAYS use the insulation wool and silicone as shown in the installation video. 13 Use 2/12 AWG electric wire with 20 amp circuit breaker. 12000 BTU = 120 volts 18000 BTU = 220 volts INSTALLATION MANUAL – Installation of the outdoor unit MANUEL MANUAL – Final stages

  • Barker SPLIT AIR-CONDITIONER, 2 Always install the indoor unit so that air can reach the most remote areas of the house. The Inside unit must be level. CAUTION Gap between ceiling and the unit 2 inches (5.1 cm) Top of the unit Gap between ceiling and the unit 2 inches (5.1 cm) Top of the unit 13 inches (3.3 cm) Total dimension from ceiling to bottom of the unit. 13 inches (3.3 cm) Total dimension from ceiling to bottom of the unit.

  • Barker SPLIT AIR-CONDITIONER, 28 OPERATION MANUAL Unit will work as follows : Run mode COOL FAN Heat Setting Temp. Setting temp.= 24°C Automatic Setting temp. = 24°C When the remote controller is lost or cannot be used due to battery run-out, please use the “Emergency” button on the unit to run on the air-conditioner. 1 3 Press the “Emergency” button. Press the “Emergency” button, the air-conditioner operate with the mode AUTO at 24°C 2 Press the “Emergency” button a second time. The unit will work in heating mode at 24°C Please press the “Emergency” button a third time to completely stop the unit. When the remote controller

  • Barker SPLIT AIR-CONDITIONER, 24 CLOCK ADJUSTMENT Remote controller (setting clock) After changing batteries, you must reset. If not reset, it may not operate properly Open the rear cover, put the batteries in. Press the HR. or the MIN. Button to set the time. Press HR. once, the time change one hour. Press MIN. once, the time change one minute. Press the CLOCK SET again, the time confirm, then closing the rear cover. Press the RESET button. Press the CLOCK SET button. Use a thin stick. Use a thin stick.

  • 5 NEVER USE insulation foam to seal the hole. ALWAYS use the insulation wool and silicone as shown in the installation video. CAUTION The exterior unit must always be level. 6 inches (15.3 cm) Minimum space back

  • Barker SPLIT AIR-CONDITIONER, 30 TROUBLE SHOOTING Code E 1 Code E 2 Code E 3 Code E 4 Code E 5 Code E 6 Code E 7 Indoor temperature sensor problem. Indoor coil temperature sensor problem. Outdoor coil temperature sensor problem. Performance problem Low temperature warning (normal) Indoor coil freezing problem Indoor fan problem Code -10 Unit will stop when outside temperature drops below -10°C. Unit will restart when outside temperature rises to -9°C.

  • Barker SPLIT AIR-CONDITIONER, 22 SLEEP OPERATION Select this function in heating or cooling mode when you want to activate sleep mode Select the following mode when the heat pump is on. To cancel sleep operation Caution Press this button to activate the sleep mode The indoor fan will be set to the slowest speed Press button again Please use this operation when you sleep. If you use this operation during day time, the room temperature will rise and the unit will not operate efficiently. In COOLING mode One hour after sleep mode start the temperature setting rises 1°C per hour for 4 hours. The unit w

  • Barker SPLIT AIR-CONDITIONER, 26 SWING OPERATION Please set swing operation if you want the cool air blow to all over the room. Please set the following operation white the air-conditioner is running. Press button to have the louvers move up and down automatically. Please press button to cancel the operation. The swing operation will be cancelled if the button is pressed. Please set this swing operation if you want the cool air blow to all over the room. Cancel the swing operation.

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Fantom Drives Gforce 3 Quick start installation manual fantom-drives/gforce-3-4J4.pdf 16 Feb 2023 10
2 Lorex L14Q684C Setup manual lorex/l14q684c-4D9.pdf 11 Jul 2023 5
3 Philips TDA1597 Datasheet philips/tda1597-7QA.pdf 16 Dec 2022 24 0.14 Mb
4 Blodgett CTB SERIES Installation & operation manual blodgett/ctb-series-X59.pdf 20 Feb 2023 77 0.81 Mb
5 Sony PCG-TR1A - VAIO - Pentium M 900 MHz Service manual sony/pcg-tr1a-vaio-pentium-m-900-mhz-723.pdf 31 Aug 2023 12 0.8 Mb
6 Philips SHK1030/27 Instructions for use philips/shk1030-27-682.pdf 28 Feb 2024 2 0.52 Mb

Similar Resources:

  • Breezaire

    WKSL SERIES

    (8 pages)
    8610 Production Avenue  San Diego, California 92121  (858) 566-7465  Fax (858) 566-1943 WKSL SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe our products are the best on the market and will provide many years of trouble free service. Please take a few minutes and read this ent …
  • flowair

    EliS A

    (32 pages)
    EN AIR CURTAIN TECHNICAL DOCUMENTATION OPERATION MANUAL PL KURTYNA POWIETRZNA DOKUMENTACJA TECHNICZNA NL ВЪЗДУШНА ЗАВЕСАТЕХНИЧЕСКА ДОКУМЕНТАЦИЯ RU ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ ELIS A | W-100 | W-150 | W-200 | E-100 | E-150 | E-200 | N-100 | N-150 | N-200 …
  • Gibson

    GAC105P1A1

    (3 pages)
    |nstailation instruct"READ BEFORE iNSTALLiNG UNiTCompact ii Window MountingYour air conditioner is designed to install in standarddouble hung windows with opening widths of 23 to 36inches (584 mm to 914 mm) (FIG. 1)Lower sash must open sufficiently to allow- a clear verticalopening of 14-1/2 inches (368 ram). Side louvers and therear of the AC must have …
  • Mitsubishi Electric

    MS-GA50VB E1 WH

    (24 pages)
    SERVICE MANUALCONTENTS1. TECHNICAL CHANGES ····································2 2. PART NAMES AND FUNCTIONS······················23. SPECIFICATION·················································44. NOISE CRITERIA CURVES················ …
  • Mitsubishi Electric

    PMFY-P·VBM-E

    (84 pages)
    ɊɍɄɈȼɈȾɋɌȼɈɉɈɍɋɌȺɇɈȼɄȿȾɥɹɨɛɟɫɩɟɱɟɧɢɹɛɟɡɨɩɚɫɧɨɣɢɧɚɞɥɟɠɚɳɟɣɷɤɫɩɥɭɚɬɚɰɢɢɜɧɢɦɚɬɟɥɶɧɨɩɪɨɱɬɢɬɟɞɚɧɧɨɟɪɭɤɨɜɨɞɫɬɜɨɢɪɭɤɨɜɨɞɫɬɜɨɩɨɭɫɬɚɧɨɜɤɟɧɚɪɭɠɧɨɝɨɩɪɢɛɨɪɚɩɟɪɟɞɭɫ� …
  • Goodman

    GSC13018

    (12 pages)
    CONDENSING AC UNITSINGLE / THREE PHASE AIR CONDITIONERSINSTALLATION & SERVICE REFERENCE© 2010-2011 Goodman Manufacturing Company, L.P.5151 San Felipe, Suite 500, Houston, TX 77056www.goodmanmfg.com -or- www.amana-hac.comP/N: IO-402E Date: December 2011Fixed OrificeCAUTIONTo prevent personal injury, carefully connect and disconnectmanifold gauge hoses. …

Comments, Questions and Opinions: