Manualios.com

Berner Aura ARA1036 Installation & Maintenance Instructions Manual

  • Aura ARA1036 Air Conditioner
  • maEMa3jtjux0Q
  • Installation & Maintenance Instructions Manual
  • PDF / Adobe Acrobat Reader
  • 8

Berner Aura ARA1036 Manual Online:

4.8, 1124 votes
Berner Aura ARA1036 User Manual
Berner Aura ARA1036 User Guide
Berner Aura ARA1036 Online Manual

Text of Berner Aura ARA1036 User Guide:

  • Berner Aura ARA1036, READ AND SAVEREAD AND SAVE READ AND SAVEREAD AND SAVE READ AND SAVE THESE INSTRUCTIONSTHESE INSTRUCTIONS THESE INSTRUCTIONSTHESE INSTRUCTIONS THESE INSTRUCTIONS No.: II-500 Date: January, 2011 © Copyright 2011 Berner International Corporation Installation & Maintenance Instructions WARNING FOR FUEL BURNING EQUIPMENT: Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and American Society for Heating, Refrigeration and Air

  • Berner Aura ARA1036, FIGURE 1 - Contents Each AURA Series carton contains the following pre-assembled components: ✓ (1) AURA air door unit ✓ (1) Louvered discharge grille ✓ (1) Perforated intake grille ✓ (2) Plastic snap ring bushings ✓ (6) No. 6 x ¾ Phillips head screws ✓ (1) Remote selector switch Optional Accessories ✓ Wall mounting plate ✓ Perforated back adapter ✓ Solid back adapter ✓ Solid back adapter (with or without lights) I. MOUNTING INSTRUCTIONS (All Models) A. Before mounting the unit, check the supporting structure to verify that it has sufficient load-carrying capacity to support the weight of the unit(s). The mounting hardware (supplied by others) should be

  • Berner Aura ARA1036, - 3 - B. WITH BACK ADAPTER: Figures 3 & 4 1. The unit may be mounted with the louvered discharge grille facing toward the door opening, or the interior of the building (electric heated models only). See Figures 3 and 4. 2. Figure 3 installation (louvered discharge grille facing in- terior of the building). Follow instructions A & B above. 3. Figure 4 installation (louvered discharge grille facing in- terior of the building). A maximum of 6” between the wall and intake grille is required. Install the back

  • Berner Aura ARA1036, - 4 - D. Mark the wall in the centers of the (4) ½” round holes pro- vided on the mounting plate. See Figure 6. If the holes on the mounting plate are not located where suitable support is available for the unit, drill new holes in the space provided on the mounting plate. E. Drill the four holes as marked on the wall and attach the mount- ing plate to the wall (mounting hardware by others). F. Raise the air door with the discharge opening facing down toward the floor. While holding the unit level, slide the heads of the shoulder bolts into the larger hole of the key- hole slots of the mounting plate. Lower the unit into place, keeping both ends level, allow

  • Berner Aura ARA1036, - 5 - IV.ELECTRICAL CONNECTIONS A. All electrical wiring and connections MUST be performed by qualified personnel in accordance with the National elec- trical Code ANSI/NFPA No. 70 (latest edition) or, in Canada, the Canadian Electrical Code, Part 1-C.S.A. Standard C22.1 and local codes and regulations. WARNING: DO NOT OPERATE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE. B. Check the rating nameplate on the top of the unit, or inside the bottom access cover, for supply voltage and current requirements. See Figure 11. A separat

  • - 6 - L. Reinstall the hinged access cover by positioning one hinge into the corresponding catch located on the unit. Raise the other hinge to the unit, when the catch is located press in the hinge and release it into the catch. Swing the access cover into place and align the mounting holes with the threaded in- serts on the unit. Reinstall the two ¼” bolts. See Figure

  • 4. Use an industrial vacuum or compressed air to remove dirt build-up from the inside of the access cover, air inlet grille, blower wheels/housings, interior of the unit, and heating coils (if applicable). Remove the dirt build-up from the blower wheels through the discharge openings on the blower plate. 5. If the unit is extremely dirty the blower plate (containing the

  • Berner Aura ARA1036, TROUBLESHOOTING SYMPTOMS CAUSE REMEDY NO AIR • Power supply line open (no power) • Check power source, check method of control in ON position • Fuse blown/circuit breaker tripped • Replace fuse(s)/reset breaker • Motor overload tripped • Internally protected motor - should reset automatically after cool-down, if not replace motor. • Failed switch • Replace switch MOTOR RUNNING/FANS ARE NOT ROTATING • Broken or flexible hub • Replace fan sleeve/reengage coupling • Shaft rotating inside fan • Tighten set screws/tighten fa

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips AZ1145 Specifications philips/az1145-V1F.pdf 05 Nov 2023 2 0.11 Mb
2 Sharp EL-501XBGR Operation manual sharp/el-501xbgr-6L4.pdf 27 Aug 2023 2 2.79 Mb
3 Sony Snc Df50n Installation manual sony/snc-df50n-2D7.pdf 24 Oct 2023 2 0.16 Mb
4 Uninet iColor LF700 Operation & user’s manual uninet/icolor-lf700-5F6.pdf 26 Apr 2023 82
5 Braun 5751 Operation & user’s manual braun/5751-BWW.pdf 03 Jan 2023 10 4.39 Mb
6 Sanyo VA-SW8000LITE Instruction manual sanyo/va-sw8000lite-YXW.pdf 19 Feb 2024 132 7.93 Mb

Similar Resources:

  • Hitachi

    RPI-10FSNE

    (374 pages)
    Read and understand this manual before using this air conditioner. Keep this manual for future reference.Lea atentamente el presente manual antes de utilizar el sistema de aire acondicionado. Guárdelo para futuras consultas.Lesen Sie dieses Handbuch gründlich durch, bevor Sie diese Klimaanlage benutzen. Benutzen Sie dieses Handbuchfür eventuell auftretend …
  • Haier

    HSU-18HEK03/R2 - annexe 1

    (16 pages)
    FACEDDrawing for the installation of indoor and outdoor unitsOptional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cableforindoorandoutdoorDrain hoseHeating insulating materialPiping hole coverFloor fixing dimensions of theoutdoor unit (Unit:mm)Fixing of outdoor unitFix the unit to concrete or blockƽwith bolts ( …
  • York

    FAN COIL YVC

    (12 pages)
    INSTALLATION, OPERATION, & MAINTENANCEFAN COILAIR CONDITIONERSSupersedes: Form 115.20-NOM3 (105)Form 115.20-NOM3 (1006)***** WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non authorized factory parts voids all warranty or implied warranty and may result in adverse operational performance and/or a po …
  • Haier

    AS50TDDHRA-CLC

    (154 pages)
    Please read this operation manual before using the air conditioner. Keep this operation manual for future referenceThis appliance is filled with R32.AS25TADHRA-CLC AS35TADHRA-CLC AS50TDDHRA-CLC AS68TEDHRA-CLCAS25TAEHRA-THCAS35TAEHRA-THCAS50TDDHRA-THCAS68TEDHRA-THCAS25THMHRA-CAS35TAMHRA-CAS50TDMHRA-CAS68TEMHRA-CNederlandsOPERATION MANUALSPLIT TYPE ROOM AIR CO …
  • Hitachi

    RPF(I)-2.5FSN2E

    (68 pages)
    RPF(I) UNITENGLISHESPAÑOLDEUTSCHFRANÇAISITALIANOPORTUGUÊSDANSKNEDERLANDSSVENSKAEVVHNIKARead and understand this manual before using this air conditioner. Keep this manual for future reference.Lea cuidadosamente este manual antes de poner en marcha el equipo de aire acondicionado. Guarde este manual en un lugar seguro por sinecesita consultarlo en el futur …
  • Campomatic

    AC19MS

    (15 pages)
    Before using your air conditioner, please readthis manual carefully and keep it for future reference.SPLIT TYPEROOM AIR CONDITIONER-Read This ManualInside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money overthe life of your air …

Comments, Questions and Opinions: