Manualios.com

C&K systems System 238 Operation & User’s Manual

  • System 238 Security System
  • maRNdeuz141dQ
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 44

C&K systems System 238 Manual Online:

3.65, 1434 votes
C&K systems System 238 User Manual
C&K systems System 238 User Guide
C&K systems System 238 Online Manual

Text of C&K systems System 238 User Guide:

  • 13 INSTANT HOME ARMING Enter your PIN (if required), push the key, enter the digit "7", the digit "4", then push the # key. PIN REQUIRED . The keypad will beep twice to confirm that the system is armed. Instant Home Arming arms perimeter zones, and bypasses interior zones (except 24-hour zones). Entry time delays are converted to INSTANT. Make sure the green RE

  • C&K systems System 238, 14 BYPASSING ZONES This procedure allows you to bypass one or more zones while your system is DISARMED 1 . NOTE: System programming determines which PINs can bypass zones, also which zones can be bypassed. To learn if a zone can be bypassed, see the ZONE DESCRIPTION LIST on pages 41-42. Enter your PIN if required. ZONE # PIN REQUIRED Push the key, enter the zone to be bypassed, then push the # key. # 1 NOTE: Zones can be also be bypassed by remote programming. When remote pro- gramming is used, the system can either b

  • 22 DURESS ALARM Should an intruder force you to turn your security system off or on, you can send a silent DURESS signal to our central station by entering User Code 7 - a code designed exclusively for a DURESS signal. Your system will appear to be operating normally. There is no indication of an alarm condition. OPTION INSTALLED (238i and 2316i ONLY)

  • C&K systems System 238, 32 LOCAL SYSTEM TEST This option allows on-site testing of each zone in your system. Enter your PIN (if required), push the key, enter the digit "6", the digit "0", then push the # key. Once the keypad lights go out, the system will be ready for testing. Walk through the areas protected by motion sensors; open and close protected doors and windows. Each time a zone is faulted, its corresponding red ZONE light on the keypad will begin flashing, and the keypad will chime. PIN REQUIRED WARNING:Your alarm system will not report alarms during the LOCAL SYSTEM TEST. . *

  • C&K systems System 238, 23 GUEST COMBINATION The SYSTEM 238 can store up to 8 PINs, and the SYSTEM 2316 can store up to 32 PINs. In both systems, PIN #8 can be programmed as a GUEST COMBINATION that will only be valid for a specified number of successive days. The countdown of days begins the first time the GUEST COMBINATION is used. NUMBER OF DAYS GUEST COMBINATION IS VALID OPTION INSTALLED Once the time expires, the GUEST COMBINATION will have to be reprogrammed before it can be used again. . OPTION INSTALLED RING BACK AFTER CLOSING When this option is installed, the bell/siren will sound for two seconds after the system is armed. If yo

  • C&K systems System 238, 36 BED- ROOM BED- ROOM BEDROOM BASEMENT Place detectors near top of stairwells BEDROOM BEDROOM KITCHEN DINING ROOM BEDROOM LIVING ROOM Best residential detector placement between bedrooms and the rest of the house K S C = CONTROL = SOUNDER = KEYPAD = SMOKE DETECTOR BED- ROOM BED- ROOM DINING ROOM KITCHEN FAMILY ROOM BED- ROOM LIVING ROOM Place detector near all sleeping areas We subscribe to the recommendations for the number and placement of smoke and/or heat detectors found in the National Fire Protection Association's Standar

  • C&K systems System 238, 15 . To bypass more than one zone: enter your PIN (if required), push the key, enter the first zone to be bypassed, push the key again, enter the next zone to be bypassed, and so on. When the last zone to be bypassed has been entered, push the # key. PIN REQUIRED To indicate that zones have been bypassed, the READY light and the ZONE light will flash slowly. The red ZONE lights of all bypassed zones will flash to remind you that bypassed zones are not protected. . . The procedures for adding a bypass and removing a bypass are identical. To remove a bypass: enter your PIN,

  • C&K systems System 238, 34 Enter your PIN (if required), push the key, enter the digit "6", the digit "1", then push the # key. If the test message was successfully transmitted to the central station, the keypad will beep twice. CENTRAL STATION TEST This option tests the reporting capability of your system by sending a test message to the central station. Weekends are the best time for the CENTRAL STATION TEST. To schedule one, call our central station at: OPTION INSTALLED CENTRAL STATION To initiate the CENTRAL STATION TEST: 6 1 PIN REQUIRED . If the test message was not successfully transmitted to the central station, the keypad will beep five times,

  • 29 User 1 can use his Master PIN to delete the PINs of Users 2 - 32 (See Note pg. 27). DELETING A USER PIN - SYSTEM 2316 AND 2316i Enter your Master PIN, push the key, enter the digit "0", then push the # key. MASTER PIN REQUIRED 0 # * * Enter zero and push the # key. 0 # Enter zero (again) and push the # key. * # Exit the programming mode by pushing the key, then the # k

  • 27 User #1 can use the Master PIN to change the PINs of Users 1 - 32 (See Below). CHANGING A SYSTEM 2316 AND 2316i USER PIN NOTE: On System 2316i, User Code #32 is reserved for special functions using the Optional Relay Output Module. Enter your Master PIN, push the key, enter the digit "0", then push the # key. * 0 MASTER PIN REQUIRED # * The READY, ARMED and SERVICE lights will

  • C&K systems System 238, 26 DELETING A USER PIN - SYSTEM 238 AND 238i Enter your Master PIN, push the key, enter the digit "0", then push the ENTER key. MASTER PIN REQUIRED The READY, ARMED and SERVICE lights will flash slowly to indicate programming mode. . User 1 can use his Master PIN to delete the PINs of Users 2 - 8. * 0 # * Enter the User number (2 - 8) you wish to delete, and push the # key. Enter the User number you wish to delete (again), and push the # key. Exit the programming mode by pushing the key, then the # key. # * * # #

  • C&K systems System 238, 9 Make sure the green READY light is on. If the READY light is not on, the red ZONE lights will indicate which zone(s) are faulted. Faulted zones must be cleared or bypassed before the system can be armed. For more information, refer to the sections Bypassing Zones and After An Alarm. TO ARM THE SYSTEM: . Your PIN number can be from two to five digits long. Don't pause for more than 5 seconds while entering the digits or the control panel will reject your PIN number. Enter your PIN and push the # key. . . PIN REQUIRED If you make a mistake while entering your PIN number, the keypad will beep five times. After

  • C&K systems System 238, 3 Getting acquainted............................................. 4-5 What the lights mean......................................... 6-7 What the sounds mean...................................... 8 Arming the system............................................. 9-15 Bypassing zones ......................................... 14-15 Arming options ................................................... 16-17 Disarming the system ........................................ 18 After an alarm .................................................... 19 Options........................

  • C&K systems System 238, 6 off on steady Power fail. System on battery. on steady Ready to arm. off on steady One or more zones are faulted. off* o n steady *Ready light will be on until system is armed. off slow flash Armed with 7 # . on* *Ready light is on if all zones are normal. slow flash on steady slow flash* Armed with 4 # . *Flashing zones are bypassed. AC FAILURE SYSTEM IS READY (ALL ZONES NORMAL) FAULTED ZONE WHILE DISARMED SYSTEM IS ARMED (ALL PROTECTION ON) PERIMETER ARMED WITH DELAYS INTACT POWER LIGHT READY LIGHT ARMED LIGHT REMARKS SYSTEM IS DISARMED (ALL PROTECTION OFF) SYSTEM IS ARMED WITH DELAY ZONES CONVERTED TO INSTANT SERVICE

  • C&K systems System 238, 33 STANDBY BATTERY TEST Your alarm system can be programmed to automatically test its standby battery every 24 hours. During the test, AC power is turned off in order to monitor the battery under load. OPTION INSTALLED To manually test the standby battery, push the key, enter the digit "6", the digit "4", then push the # key. . 46 . The standby battery test takes 2 minutes. During the test, the green AC light will be off. If the battery is okay, the keypad will beep twice. If the battery is low or dead, the POWER light will flash slowly, the SERVICE light will be

  • C&K systems System 238, 24 User 1 can use his Master PIN to change the PINs of Users 1 - 8. CHANGING A SYSTEM 238 AND 238i USER PIN 0 MASTER PIN REQUIRED . # * * . # # If the new PIN is accepted, the keypad will beep twice. If you make a mistake while programming, or if the system rejects the new PIN, the keypad will beep five times. Enter the new PIN again and push the # key. The new PIN can be from two to five digits long, but must start with the same first digit as the old PIN. Enter the new PIN and push the # key. The READY, ARMED and SERVICE lights will flash slowly to indicate programming mode. Enter your Master PIN, push the key, enter the digit "0", then p

  • C&K systems System 238, 38 ALARM A condition that occurs when the detection devices in a zone are triggered after the system is armed. EXIT DELAY Once the system is armed, the time you have to exit the premises through a DELAY DOOR (before an alarm occurs). The delay time is programmable from 10 seconds to 150 seconds. ALARM MEMORY Alarm conditions are stored in memory until cleared. BYPASS To take a zone out of the circuit. Bypassing malfunctioning zones allows the rest of the system to be armed. Bypassing interior zones allows freedom of movement inside the premises, while leaving outer zones armed. Bypassed zones are not protected. CENTRAL STATION The offic

  • C&K systems System 238, 2 Thank you for purchasing this C&K alarm system. Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide you with years of reliable operation. This manual explains how to operate your alarm system. Basic operating instructions are also printed on the small label attached to the inside of your keypad(s) door. If you have questions or need help with your alarm system, call: ______________________________________ ______________________________________ (Alarm Company Name) If y

  • C&K systems System 238, 31 DOOR CHIME When this option is installed, the keypad will beep for two seconds each time a designated zone is faulted. OPTION INSTALLED To turn the Door Chime on and off: Push the key, enter the digit "5", then push the # key. 5 STANDBY BATTERY Should there be a loss of AC power, the green POWER light on the keypad will go out, and your alarm system will switch to its standby battery. If an AC power failure lasts for more than 15 minutes, the yellow SERVICE light on the keypad will come on. OPTION INSTALLED # * * . The standby battery should be replaced every four to six years with a

  • C&K systems System 238, 8 SOUND MEANING 2 beeps system armed or disarmed . successful central station test or battery test . 5 beeps invalid function unauthorized command attempted error changing PIN number wrong PIN number entered . . . . . continuous tone, beeping fast for last ten seconds entry delay time continuous beeping, speeding up for last ten seconds exit delay time 2 second beep door chime ring back after closing report . . . zone faulted during walk-test chirping (1 second on, 4 seconds off) chirp alert warning: system is armed, but a Delay zone is faulted; you must disarm the system before entry delay expires or alarm will occur zone programmed to chirp is in alarm continuo

  • C&K systems System 238, 17 CHIRP ALERT The system will arm even if delay zones are faulted at the time of arming. If a zone is still faulted when the EXIT DELAY time expires, the bell/siren will begin to chirp. The chirping will continue for the duration of the ENTRY DELAY time. You must re-enter the premises and disarm the system before the ENTRY DELAY time expires or an alarm will occur. OPTION INSTALLED

  • C&K systems System 238, 20 24-HOUR MONITORING With this option installed, your alarm system will transmit alarm signals to our central station. OPTION INSTALLED FIRE KEY When this option is installed, holding down the key for three seconds will trigger an alarm. The keypad will beep twice to confirm the alarm condition. OPTION INSTALLED EMERGENCY KEY Holding the key down for three seconds will trigger an alarm. The keypad will beep twice to confirm the alarm condition. OPTION INSTALLED NOTE: The System 238 and System 2316 have not been investigated by Underwriters Laboratories for compliance with UL1637, Home Health Care Signalling Equipment.

  • C&K systems System 238, 16 Your alarm system has been programmed for one of the following three arming types: GOOF-PROOF ARMING If any zone other than a 24-hour zone is faulted (open window, malfunction- ing sensor, etc.), your system will not arm. You will not be able to arm the system until the faulted zone is cleared or manually bypassed. FORCE ARMING Any zone (except for 24-hour zones) that is violated after the EXIT DELAY time has expired will be automatically bypassed until the system is disarmed. Warning: bypassed zones are not protected. OPTION INSTALLED OPTION INSTALLED

  • C&K systems System 238, 4 What your alarm system is... Your alarm system is made up of a control panel and several detection devices like motion sensors, magnetic contacts, and so on. Specific areas of detection are called zones. Zones can be programmed to have different characteristics. Some zones may be 24-hour zones, that is, they remain armed even when the alarm system is off. Zones used for fire detection, for example, are always 24-hour zones. In addition, some zones can be programmed to allow bypassing. When you bypass a zone, you temporarily remove it from the alarm system. Always remember, however, that bypassed zones are not protected. How your alarm system works... When a detectio

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Jade TITAN JTKC-24 Features & dimensions jade/titan-jtkc-24-9I3.pdf 20 Sep 2023 2
2 Jenn-Air JMW2327 Use & care manual jenn-air/jmw2327-9CU.pdf 18 Apr 2023 56
3 Monessen Hearth Vent Free DFX32C Product specifications monessen-hearth/vent-free-dfx32c-2P9.pdf 08 Aug 2023 1
4 NETGEAR GS105v4 Installation manual netgear/gs105v4-RRU.pdf 04 Jul 2023 2
5 Husqvarna BE550 Parts manual husqvarna/be550-29O.pdf 26 Sep 2023 14
6 Philips 37PFL5332D Quick start manual philips/37pfl5332d-7V9.pdf 28 Jan 2023 1 13.06 Mb

Similar Resources:

  • Konlen

    KL-H50

    (19 pages)
    KONLEN TECHNOLOGY LIMITED Website: www.konlen.com U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China Tel: +86-(0)755-86082432 E-mail: [email protected] MSN: [email protected] Skype: securitykonlen - 1 - KL-H50 GSM HOME ALARM SYSTEM WITH LCD …
  • Fike

    326-0021

    (4 pages)
    26-0980 Issue 6 General Description The Sita Sounder/Strobe unit allows for audible and visual indication when the system enters an alarm condition. This is an addressable unit that attaches to the loop. Digital communication technology to the control panel is implemented allowing for accurate data transfer at high transmission speeds. This device is o …
  • Aiphone

    AX-084C

    (8 pages)
    - INITIAL INSTALLATION INSTRUCTIONS -On/Off power switchRS232 portUsed for programmingTwo 24V DC inputsParallel inputs on 1 PS-2420UL for audio-only systemsTelephone OutputConnects to Viking Model K-1900-5 DialerMaster Station PortsRJ-45 jacksVideo Outputs.Each talk path has its own output.When connecting to a DVR, two channels must be used.Door Release Con …
  • Velleman

    CCTVPROM15

    (55 pages)
    CCTVPROM15 CCTV-PACK PUSH VIDEO EAGLE EYES: H.264 FULL FRAME DVR + 4 SONY EFFIO IR CAMERAS + ACCESSORIES + 500GB HARD DISK CCTV-PACK PUSH VIDEO EAGLE EYES: H.264 FULL FRAME DVR + 4 SONY EFFIO IR-CAMERA'S + ACCESSOIRES + HARDE SCHIJF 500GB PACK VIDÉOSURVEILLANCE 'PUSH VIDEO' EAGLE EYES: ENREGISTREUR VIDÉO H.264 PLEIN ÉCRAN + 4 CAMERAS IR …
  • Toa

    VX-3000 SERIES

    (162 pages)
    INSTALLATION MANUALINTEGRATED VOICE EVACUATION SYSTEMVX-3000 SERIESThank you for purchasing TOA’s Integrated Voice Evacuation System. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.1134TOA Electronics Europe GmbHSuederstrasse 282, 20537 Hamburg, Germany1134-CPR-195EN 54-16: 2008Fire Detection and …
  • AJAX

    MotionProtect

    (23 pages)
    MotionProtect Outdoor User ManualUpdated June 24, 2020MotionProtect Outdoor is a wireless outdoor motion detector for the Ajaxsecurity system. The detector communicates with the hub via protected radio protocol at a distance up to 1,700 meters in the line of sight.MotionProtect Outdoor features protection against blocking the detector view(anti-masking syste …

Comments, Questions and Opinions: