Manualios.com

BHM Electronics 3 C-FAX User Handbook Manual

BHM Electronics 3 C-FAX Manual Online:

3.7, 2142 votes
BHM Electronics 3 C-FAX User Manual
BHM Electronics 3 C-FAX User Guide
BHM Electronics 3 C-FAX Online Manual

Text of BHM Electronics 3 C-FAX User Guide:

  • BHM Electronics 3 C-FAX, CONTENTS Introduction 3 Unpacking 3 Mounting 4 Connecting Power and Aerial 4 Connecting an External Receiver 5 Loading Paper 6 The Controls 7 Using the C-Fax 8 Sample Weather Maps 10 Weather Map Abbreviations 11 Detailed Description of the Controls 12 Care of the C-Fax 14 Trouble Shooting 15 Replacing the Fuse 15 Specifications 16 Wiring Connections 17 Frequency List 18 2

  • BHM Electronics 3 C-FAX, Introduction The C-Fax radio facsimile receiver has been designed as an easy to use, reasonably priced unit with low operating costs. The materials and finishes used ensure durability and long life, and the small size enables fitting in areas where space is at a premium. The C-Fax uses standard fax paper as used in telephone fax machines. This paper is generally available from any office supply shop or stationer. Information contained in the weather maps received can be analysed to give useful insight into the weather trends for your particular part of the world. This makes it a valuable tool for t

  • Mounting the C-Fax The C-Fax may be left free standing or wall mounted on the supplied bracket. To fix the C-Fax to a wall, remove the mounting bracket from the rear of the C-Fax by taking out the two screws holding it at the bottom. Screw the bracket to the wall, slide the C-Fax back onto the bracket and replace the two bottom screws. Connecting Power Plug the power lead int

  • BHM Electronics 3 C-FAX, Using an External Receiver An external receiver may be used with the C-Fax and is required if your model has no internal receiver. It must be a crystal controlled or synthesised SSB (single side band) type, with LSB (lower side band) mode. Connection should be made from either the speaker output or line level output of the external receiver to the audio socket on the side panel of the C-Fax. This input will accept a wide range of signal levels from 1V to 5V RMS. Putting a plug into the external receiver s

  • BHM Electronics 3 C-FAX, Loading Paper The C-Fax uses standard telephone fax machine paper, 216mm wide. The recommended paper length is 30m, longer rolls may not fit. To load a roll of paper into the C-Fax, open the two catches located each side on the front. Pull the lower edge of the catch away from the C-Fax and then unhook the upper edge. The lower section of the case will then open down. Remove the empty roll by pushing it to the right against the spring and then pulling it up and out. Insert a new roll of paper by pushing the right end against the spring and then pushing the left end down. Mak

  • BHM Electronics 3 C-FAX, The Controls 1 2 3 45 6789 10 11 12 13 14 Brief Description of the Controls 1 Audio On/Off/Picture Align Up - received signal audible Centre - no audio Down - hold down to manually align picture 2 Align Indicator - used for manual align 3 Fast Paper Feed 4 Paper Out Indicator 5 Stop/Auto/Start Up - receiver only, no printing Centre - automatic start/print/stop Down - continuous printing 6 Run Indicator - printer is operating 7 Power On/Off 8 Data Indicator - printing signal 9 Channel Display (internal receiver model only) 10 Channel Selection Buttons (internal receiver model only) 11 Fuse 12 Power Input Socket 13 External Receiver Inp

  • BHM Electronics 3 C-FAX, Using the C-Fax Switching On Make sure power plug and aerial connections have been made and that a roll of paper is properly inserted in the C-Fax, as described on pages 4 to 7. Move the power switch (number 7 in the picture on the previous page) down. If your C-Fax has an internal receiver the channel display (9) should show the current channel number, location and frequency the C-Fax is listening to. for example: 3 Auckland ZKLF 13550.5kHz This indicates that the receiver is set to channel 3, which transmits from Auckland on a frequency of 13550.5 kHz (kilohertz) using the call sign Z

  • BHM Electronics 3 C-FAX, picture generally takes about 15 minutes to send. Finally the stop signal is sent. This is 5 seconds of alternating tones followed by 10 seconds of a steady tone. You may turn off the audio by putting the Audio switch (1) back to the middle position. It is only required for determining the signal quality of a channel. While the C-Fax is left on Automatic it will start and stop printing whenever a picture is received. You will generally not need to do anything else. If for some reason the C-Fax misses the stop signal, for example if the radio signal becomes very noisy or fades, it will continue to print even after the picture has finished. A built in timer will automatically sto

  • BHM Electronics 3 C-FAX, Sample Weather Maps Australia Significant Weather Prognosis Australia Mean Sea Level Prognosis Darwin Tropics Significant Weather Prognosis Indian Ocean Mean Sea Level Prognosis Example of a noisy signal 10

  • BHM Electronics 3 C-FAX, Weather Map Abbreviations These are some of the common abbreviations you will see on weather maps. Map areas ASIA 50°N to 50°S, 100°E to 180° IO Indian Ocean NPAC 50°N to 50°S, 160°E to 110°W NREG Equator to 50°S, 140°E to 140°W NZ New Zealand SPC South Pacific (Australia to South America) SWP South West Pacific (Australia to Tahiti) TNZ Tasman Sea and New Zealand Map Types ANAL Analysis FCST Forecast MAR WX Significant Marine Weather NEPHANAL Nephanalysis (analysis of cloud information taken from satellite pictures) PROG Prognosis SIG WX Significant Aviation Weather TEMP Temperatures Levels MSL Mean Sea Level 700MB Height of 700 millibar pres

  • Detailed Description of the Controls Numbers in brackets refer to the picture on page 6 Audio On/Align switch (1) and Align light (2) When this switch is placed in the up position then audio from the receiver can be heard. This can be used to listen to the quality of the radio reception on any of the channels. Placing the switch back in the center position turns off

  • BHM Electronics 3 C-FAX, Note: Some brands of paper are glued to the center core, in this case the paper out light will not operate as the paper remains in the print area. If you find this happening try changing the roll within a few maps of the warning stripe appearing. Stop/Auto/Start switch (5) and Run light (6) In the up position the printer is off. Only the receiver is working. The green run light is off. In the centre position the printer automatically starts and stops printing pictures using the received start and stop signals. The run light is on during printing. In the down position the printer starts and prints continuously.

  • BHM Electronics 3 C-FAX, Care of the C-Fax There are no parts to be lubricated. When a new roll of paper is fitted remove any paper scraps or dust from the paper compartment. At this time also check and clean the rubber pressure roller if necessary. The roller should only be cleaned with alcohol. If a printed picture has vertical light stripes through it the most likely cause is dirt on the print head. If this problem appears open the paper compartment and check the print head, which is mounted on a horizontal metal bar at the top of the paper compartment. Near the top of the print head (about 5mm above the line of black rubber) is a thin black line, this is the thermal print line. Dirt on this print

  • BHM Electronics 3 C-FAX, Trouble Shooting Unit is dead - no lights Check Power switch is on (down) Power lead is connected Fuse on side panel is intact Power polarity, red wire of lead is positive, black is negative Voltage to the C-Fax is correct, between 12 and 15V If all these check ok, or if the fuse fails again after replacement, seek technical assistance. No Printing Check Paper Out light is not flashing, if it is replace the paper Paper is fitted correctly Run switch is in Auto or Start position Replacing the Fuse The fuse on the si

  • BHM Electronics 3 C-FAX, Specifications RECORDING SYSTEM Printing by static thermal head on thermal paper RECORDING PAPER High sensitivity thermosensitive INDEX OF COOPERATION 576 SCANNING SPEED 120 lines per minute RESOLUTION 8 dots/mm START AND STOP Automatic or manual PHASING Automatic or manual DATA TONES White 1500Hz Black 2300Hz RECEIVING SYSTEM Double conversion superheterodyne NUMBER OF CHANNELS up to 203 pre-programmed FREQUENCY RANGE 50kHz to 30MHz RECEPTION MODE F4 RECEIVE IF FREQUENCY 45MHz & 455kHz BFO FREQUENCY 453.1 kHz SENSITIVITY 2 microvolts for useable copy DIMENSIONS 322mm wide x 250mm high x 95mm deep WEIGHT Approx. 4kg MOUNTING POSITIONS Vertical or horizontal, free sta

  • BHM Electronics 3 C-FAX, Wiring Connections Power Supplied via a 4 pin round line socket, standard threaded locking collar. 1 23 4 +- Side Panel Power pin 1 unused pin 2 negative (black) pin 3 positive (red) pin 4 unused Power supply 12 to 15V DC at 1.5A, 12W maximum Audio In Standard 3.5mm mono audio plug for external receiver. Center is signal, outside is signal return. Level:100mV to 3V RMS 17

  • BHM Electronics 3 C-FAX, Frequency list for the C-Fax Channel Frequency Call Location/Country sign 1 Auckland 5807.0 kHz ZKLF Auckland,New Zealand 2 Auckland 9459.0 kHz ZKLF 3 Auckland 13550.5 kHz ZKLF 4 Auckland 16340.1 kHz ZKLF 5 Melbourne 2628.0 kHz AXM31 Melbourne,Australia 6 Melbourne 5100.0 kHz AXM32 7 Melbourne 11030.0 kHz AXM34 8 Melbourne 13920.0 kHz AXM35 9 Melbourne 20469.0 kHz AXM37 10 Darwin 5755.0 kHz AXI32 Darwin,Australia 11 Darwin 7535.0 kHz AXI33 12 Darwin 10555.0

  • 61 Tokyo JMH 13597.0 kHz JMH4 62 Tokyo JMH 18220.0 kHz JMH5 63 Tokyo JMH 23522.9 kHz JMH6 64 Tokyo Radio 4316.0 kHz JJC Tokyo Radio,Japan 65 Tokyo Radio 8467.5 kHz JJC 66 Tokyo Radio 12745.5 kHz JJC 67 Tokyo Radio 16971.0 kHz JJC 68 Tokyo Radio 17069.5 kHz JJC 69 Tokyo Radio 22542.0 kHz JJC 70 Seoul 5835.0 kHz

  • BHM Electronics 3 C-FAX, 126 Maritime Air 14626.0 kHz CZW 127 Bracknell 2618.5 kHz GFE25 Bracknell,United Kingdom 128 Bracknell 4610.0 kHz GFA22 129 Bracknell 8040.0 kHz GFA23 130 Bracknell 14436.0 kHz GFE23 131 Bracknell 18261.0 kHz GFE24 132 Northwood 2618.5 kHz GYA Northwood,United Kingdom 133 Northwood 4610.0 kHz GYA 134 Northwood 8040.0 kHz GYA 135 Northwood 11086.5 kHz GYA 136 Hamburg 3855.0 kHz DDH3 Hamburg/Pinneburg,Germany 137 Hamburg

  • 191 Nairobi 12315.0 kHz 5YE2 192 Nairobi 15525.0 kHz 5YE9 193 Nairobi 16315.0 kHz 5YE6 194 Nairobi 17365.0 kHz 5YE3 195 Nairobi 22867.0 kHz 5YE7 196 Test 1750kHz 1750.0 kHz test Receiver test frequencies 197 Test 3.5MHz 3500.0 kHz test 198 Test 7.0MHz 7000.0 kHz test 199 Test 14.0MHz 14000.0 kHz test 2

  • BHM Electronics 3 C-FAX, Manufactured by BHM Electronics Invercargill New Zealand Postal Address: PO Box 787, Invercargill Delivery: 287 Dee Street, Invercargill Phone: 0-3-218 3495 Fax: 0-3-218 3494 International Phone: +64 3 218 3495 International Fax: +64 3 218 3494 E-mail: [email protected] Web: bhmelectronics.co.nz 22

Related Products and Documents (Radio):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 STEINEL NIGHTMATIC 3000 Operating instructions steinel/nightmatic-3000-Z6E.pdf 15 Nov 2023 3 0.09 Mb
2 Harman Kardon HK 980/230 Service manual harman-kardon/hk-980230-9E9.pdf 25 Mar 2023 50
3 Car Solutions MB-PAS-151118 Operation & user’s manual car-solutions/mb-pas-151118-AH3.pdf 08 Dec 2023 30
4 Perle IDS-409-SFP Hardware installation manual perle/ids-409-sfp-111.pdf 18 May 2023 40
5 Zojirushi Mr.Bento SL-JA14 Instruction manual zojirushi/mr-bento-sl-ja14-795.pdf 28 Oct 2023 2 0.76 Mb
6 Whirlpool RF377PXX Use & care manual whirlpool/rf377pxx-FIA.pdf 21 Apr 2023 24

Similar Resources:

  • Kompernass

    KH 2175

    (42 pages)
    3A+BKOMPERNASS GMBH · BURGSTRASSE 21 ·D-44867 BOCHUMwww.kompernass.comID-Nr.: KH2175-07/08-V2BATHROOM RADIOBathroom RadioOperating instructionsKylpyhuoneen radioKäyttöohjeBadrumsradioBruksanvisningKH 2175Ραδιοφωνου µπάνιουΟδηγίες χρήσης …
  • Etón

    ELITE 750

    (37 pages)
    © Copyright 2020 Etón Corporation. All Rights Reserved. Grundig Radio Line By Etón CorporationELITE 750AM/FM-stereo/Shortwave/Airwave Band Radio with SSB (Single Side Band)OWNER’S MANUAL …
  • CCE

    RADIO MOBILE RX 868 MHz

    (2 pages)
    Power SupplyMax Absorbed CurrentMax Relay Contact CurrentSafety Edge -1 (Device 1) ActiveSafety Edge -2 (Device 2) ActiveReceivingLow BatteryActivated DeviceNo SignalPower Supply LedAlimentazioneCorrente Max Assorbita Corrente Max Contatto RelèCosta -1 (Device 1) AttivaCosta -2 (Device 2) AttivaRicezione In CorsoBatteria ScaricaIntervento DispositivoMancanz …
  • Philips

    ACT100

    (12 pages)
    knapplås / allmän informationanvända knapplåset avaktiverar de andra knapparna så att de inte trycks av misstag. aktivera / avaktivera knapplåset, tryck display: visas om knapplåset är aktiverat.att tänka på när du använder hörlurar skydda din hörsel: lyssna på en rimlig nivå. hög volym i hörlurarnakan påverka din hörsel negativt.trafik …
  • Konig

    HAV-SR41

    (27 pages)
    HAV-SR41MANUAL (p. 2)Shower RadioMODE D’EMPLOI (p. 5)Radio doucheMANUALE (p. 9)Radio per Doccia con OrologioBRUKSANVISNING (s. 15)DuschradioMANUAL DE UTILIZARE (p. 19)Radio pentru duşBRUGERVEJLEDNING (p. 23)BruserradioHASZNÁLATI ÚTMUTATÓ (o. 12.)ZuhanyrádióKÄYTTÖOHJE (s. 14)SuihkuradioANLEITUNG (s. 3)DuschradioGEBRUIKSAANWIJZING (p. 7)DoucheradioMA …
  • MFJ

    MFJ-260C

    (2 pages)
    MFJ-260C Dummy Load Instruction ManualVersion 0B Page 1 MFJ Dummy Loadmodel MFJ-260CThe MFJ-260C Dummy load is a dry, air cooled, resistive dummy load. This resistor loadis capab …

Comments, Questions and Opinions: