  • ATTACK DP STANDARD, 11 Required boiler temperature [C 80] - is temperature that the regulator tries to reach in the operation mode. It is set by direct turning of button of the boiler thermostat and it is indicated by short displaying. Set temperature of the flue gas / room thermostat [100C] - this parameter indicates temperature set by additional flue gas / room thermostat. In accordance to installation of heating and setting of parameter FC (1 or 0) it represents the flue gas temperature (at lower actual temperature, the regul

  • ATTACK DP STANDARD, 18 Purpose of use Ecological hot-water boiler Attack DP is designed for heating of family houses and similar objects. The boiler is designed for burning wood only. Any dry wood can be used for burning, mainly logs. Also wood of bigger diameter, blocks, can be used, which reduces nominal output but prolongs burning time. The boiler cannot be used for burning filedust and small wooden debris. This can be burnt only in small amount together with logs (max. 10%). Due to its large feed hopper you can avoid the most demandable operation

  • ATTACK DP STANDARD, Výrobca ATTACK s.r.o. si vyhradzuje právo technických zmien výrobkov bez pred- chádzajúceho upozornenia. • ATTACK, s.r.o. producer reserves the right to change technical parameters and dimensions of boilers without previous warning. • Der Hersteller ATTACK, s.r.o. behält sich das Recht der technischen Veräderungen an Produkten ohne eine vorige Warnung. • Изготовитель АТТАСК оставляет за собой право изменени�

  • ATTACK DP STANDARD, 15 Additional output. Mode of additional output [Ar 0] - regulator is equipped with the multi-purpose output that can work under one of the following outputs: Mode [Ar 0] – can control oil or gas boiler, if it is connected into the heating system. When the regulator is started by the main switch, the additional boiler is stopped and it is started again, when there is already no fuel in the solid fuel boiler. This function is useful in the heating systems, where the solid fuel boiler is used to decrease the heating costs. When the fuel shortage alarm is removed by the STOP button, the additional boiler is stopped again and the regulator works again. �

  • ATTACK DP STANDARD, 14 Time of pause of the C.H. pump [Pc --] - when the boiler temperature exceeds the temperature set by parameter [P 65] and operation mode stops the pump (e.g. when the contacts of thermo- stat are open or when the fan is stopped), can the pump be regularly started for 30 seconds to pump water into the heating system. This parameter sets pause time in minutes between operation cycles of the pump. Setting of this parameter to „--“ inactivates this function. Delay of the C.H. pump stop [Pd 2] – too early C.H. pump stop might cause boiler tempera- ture increase and consequently its overheating. This parameter enables

  • 16 control light of the room thermostat will shine, because the boiler should keep the temperature set by the boiler thermostat. When the room temperature exceeds the set temperature, control light of the room thermostat expires and the boiler switches into the mode of fire keeping at minimum boiler temperature. Device is designed to enable connection of alternative e

  • 21 The boiler overheating If the temperature of the boiler raises to more than 95 °C, the regulator stops the flue-gas fan and the control light of boiler overheating shines on. For new start it is necessary to: - wait until the boiler temperature falls - remove the cause of boiler overheating (e.g. refill missing water into the central heating circuit) Warning! Water can be refilled onl

  • ATTACK DP STANDARD, 27 The variants of connections The variant of connection with the regulating system REGUMAT ATTACK-OVENTROP ATTACK DP boiler Expansion vessel The pump Regumat ATTACK- -OVENTROP Heating system Storage tank for DHW 1 2 43 Return flap Return Flap

  • ATTACK DP STANDARD, 23 Note Logs of bigger dimensions is necessary to cut into halves or quarters (because of the requirement of operation to nominal output). You can burn hard as well as soft wood. Wood must be dried! Boiler output depends on the moisture content of wood. Output and function of the boiler is guaranteed for maximum moisture content of 20%. Location of the boiler: For the installation it is necessary to keep safe distance of its surface from flammable materials by the degree of flammability and combustibility: - materials B, C1 and C2 200mm - materials C3 400mm - materials with the degree not tested by STN 73 0853 400mm Exampl

  • ATTACK DP STANDARD, 22 Permanent-heat operation Permanent-heat operation of the boiler means that the fire can be kept during the night without heating up daily, but only in winter. This way of operation shortens the service life of the boiler. For permanent-heat operation prepare the boiler this way: - Put a few bigger logs (4-6)on the glowing layer - Get the mixing valve ready. After closing the valve the temperature of water rises to 80- 90°C. - Regulation flap controlled by the thermoregulator is closed automatically and the fan is switched off. In th

  • ATTACK DP STANDARD, 26 VERSION 1 VERSION 2 VERSION DP75 VERSION DP95 Installation and exchange of the heatproof shaped piece ( version 1) The back part of the ash pan pos. 1 insert into the lower chamber and push to stop to the back plate. Insert the front part of the ash pan pos. 2 and push to stop to the back part of the ash pan. Put the super-structure of the ash pan pos. 3 on the ash pan and push it to stop to the rear. The ash pan should be situated in the centre lime of the boiler at the front sight.When exchanging damaged jet pos. 4 or cube pos. 5 , follow the next instructions: Take out the jet and the cube / the cube in DP35 and DP 45 only/ after the elimination of

  • 4 Introduction: Dear customer, Thank you for confidence that you showed us by purchasing our product - ATTACK wood gasifying boiler. We wish you long and reliable operation. Proper attendance of the boiler is one of the conditions for reliable and right operation, so please read this instruction for use carefully. The manual is written in the way to respect

  • ATTACK DP STANDARD, 35 2 3 4 5 6 7 8 9 10 11 12 2 3 4 1 2 4 4 230V/50Hz 1 KO 1 2 4 5 2 1 4 4 2 2 230V/50Hz L N N L N L HV - Main switch ST - Flue gas thermostat KT - Boiler thermostat BT - Safety thermostat KO - Condensator 1 - Black wire 2 - Blue wire 3 - Brown wire 4 - Green-yellow wire 5 - Red wire - Pump - The fan - Earthing TC - Pump thermostat THE KEY FOR DP BOILERS ATTACK DP PROFI 25 - 75

  • ATTACK DP STANDARD, 28 The variant of connection with the accumulation tank ATTACK DP boiler Regumat ATTACK- -OVENTROP Heating system THE ACCUMULATION T ANK STORAGE TANK FOR DHW The pump Expansion vessel the return flap The boiler has to be operated continuously in nominal output. In case of heat outlet when the boiler operates on a lower output that the nominal, it is necessary to attach the boiler to the accumulation tank of the volume of min. 460 litres (STN EN 303-5, paragraph 4.2.5 ). 1. Regumat is used to increase the reurn heating water temperature returning into the boiler to more than

  • 37 Stamp, signature of service organization : ......................................... Obligatory service examination after the 1st year of operation Date : ........................................ Stamp, signature of service organization : ..........................................

  • ATTACK DP STANDARD, 25 Section cross boiler - combustion chamber Attachment of regulation and control elements The boiler is delivered to a consumer equipped with basic regulation and control elements. Attachment of these elements is indicated on the chart of connection. We recommend to extend the regulation of boiler with other regulation elements which enable more comfortable and economic operation. Each pump in the system must be controlled by an individual thermostat so as the boiler was not undercooled on th

  • ATTACK DP STANDARD, 10 Actual value of this setting can be also checked in the temperature display mode. If the flue gas temperature is in the operation mode after burning-up lower than the value set by the button of additional thermostat, then the suction fan and the circuiting pump are blocked, which is signalized by flickering of additional thermostat´s control light. In this case it is necessary to decrease the adjusted flue gas temperature value by the button of additional thermostat, until

  • ATTACK DP STANDARD, 2 ATTACK DP - Wood gasifying boiler - Assembly, pre-heating and training of the attendance is perfomed by an assembly technician trained by the manufacturer, who also fills in a document on the installation of the boiler. -During wood gasifying, tar and condensates (acids) are created in the fuel bin. Therefore behind the boiler the mixing appliance regumat must be installed to keep the minimum temperature of return water of 65°C into the boiler. - Operation temperature of water in the boiler must be of 80-90°C. - The boiler must not be permanently operated with the output lower than 50%. - When a ci

  • ATTACK DP STANDARD, 29 2. Connection with accumulation tank Connection system consists in heating up of water in accumulation tanks and the warmth is gradually taking away from the tanks according to the request from the heating system. By the operation with several heating ups at full performance, accumulation tanks will be heated for the temperature of 90-100°C. Heating with accumulation tanks in connection with the ATTACK DP boilers bring more advantages. Among the main advantages belong enlargement of the boiler life and in the end result also

  • ATTACK DP STANDARD, 32 Scheme of dependency of resistance on the temperature of heating water by the thermal probe ( DP PROFI ) Temprerature °C -55 -50 -40 -30 -20 -10 0 10 20 25 30 40 50 60 70 80 90 100 110 120 125 130 140 150 951 1000 1105 1218 1338 1467 1603 1748 1901 1980 2057 2217 2383 2557 2737 2924 3118 3318 3523 3722 3815 3901 4049 4153 Resistance kOhm 980 1030 1135 1247 1367 1495 1630 1772 1922 2000 2080 2245 2417 2597 2785 2980 3182 3392 3607 3817 3915 4008 4166 4280 1009 1059 1165 1277 1396 1523 1656 1797 1944 2020 2102 2272 2451 2637 2832 3035 3246 3466 3691 3912 4016 4114 4283 4407 MIN MAX

  • ATTACK DP STANDARD, 6 Dimensions of ATTACK DP boilers Key: 1. Boiler body 2. Upper cover 3. Feeding door 4. Ashtray door 5. Pull rod of the heat up flap 6. Cover of cleaning opening 7. Aftercooling circuit 8. Chimney 9. Suction fan 10. Outlet valve 11. C.H. return connection 12. C.H. flow connection 13. Primary air flap 14. Secondary air flap 15. Regulation door 16. Output regulator 17. Control electronics - PROFI version 18. Pressure gauge ATTACK DP 25-45 ATTACK DP 75 ATTACK DP 95

  • ATTACK DP STANDARD, 9 Technical description and ways of regulation of the ATTACK PROFI boiler Boiler temperature is kept at the level set at by user by means of control of the flue gas ventilator´s rotations. Regulator measures temperature of water in boiler, indicates it on display and controls suction fan and circuiting pump. Regulator is equipped with additional flue gas thermostat and terminals to connect its sensor. Adequately to the situation, it is possible to use thermostat to set the flue gas temperature for indication of fuel shortage and boiler stop, or for setting of required temperature in the r

  • ATTACK DP STANDARD, 24 Chimney Attachment of the appliance to the flue must be always done with approval of authorized chimney- sweeping company. There must always be sufficient draft in the flue and flue gas must be draught to the atmosphere in all possible operation conditions. For the right operation of the boiler the independent flue must be dimensioned in the right way, because combustion, output and service life of boiler depends on the draught. The draught is influenced by the section of flue, height and roughness of the internal wall. Into th

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Clarion DX515 Owner's manual clarion/dx515-BCF.pdf 25 Oct 2023 16 0.42 Mb
2 Philips 150T4FS Operation & user’s manual philips/150t4fs-2X6.pdf 17 Jul 2023 122 0.95 Mb
3 PYLE Audio PYLE Hydra Series PLMR19W Owner's manual pyle-audio/pyle-hydra-series-plmr19w-24E.pdf 11 Apr 2024 14
4 Reliable End Cutter With 96" Track & Lifter Set XD-510L Specifications reliable/end-cutter-with-96-track-lifter-set-xd-510l-Y43.pdf 15 Jul 2023 1 0.17 Mb
5 Acer TravelMate 6492 Series Service manual acer/travelmate-6492-series-8QO.pdf 31 Jul 2023 190
6 Simplicity 4000 Parts manual simplicity/4000-Q8I.pdf 15 Mar 2024 44 0.37 Mb

Similar Resources:

  • BRÖTJE

    RGT B

    (168 pages)
    DEMontageanleitungRGT B / RGTK BRGTF B / RGTKF BGBInstallation instructionsRGT B / RGTK BRGTF B / RGTKF BFRInstructions de montageRGT B / RGTK BRGTF B / RGTKF BITIstruzioni di montaggioRGT B / RGTK BRGTF B / RGTKF BPLInstrukcja montażuRGT B / RGTK BRGTF B / RGTKF BDKMonteringsvejledningRGT B / RGTK BRGTF B / RGTKF BNLMontagehandleidingRGT B / RGTK BRGTF B / …
  • Zip

    HydroTap G5 Touch-Free Wave

    (28 pages)
    Quick Start Installation Guide 807120 v1.00 01.21 G5 C CS Quick Start Guide1Zip HydroTap G5Quick Start Installation GuideCommand Centre Chilled, Chilled/Sparkling modelsAFFIX PRODUCT LABEL HEREVisit our website to download the manualsAustralia UK …
  • Ferroli

    ECONCEPT 35 C

    (108 pages)
    )cod. 3540F320 — 02/2007 (Rev. 00)ECONCEPT 35 CINSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCEINSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIENȅǻǾīǴǼȈ ȋȇdzȈǾȈ, ǼīȀǹȉDZȈȉǹȈǾȈ Ȁǹǿ ȈȊȃȉdzȇǾȈǾȈKULLANMA, KURULUM VE BAKøM TALIMATLARø …
  • Ravenheat

    RSF 84E

    (55 pages)
    ELECTRONIC IGNITION - AUTOMATIC MODULATING BOILERFANNED COMBIRSF 84E - RSF IOOERSF 84ET - RSF IOOETWITHOUTTIMERRSF 84E G.C. No 47 581 27ARSF 1OOE G.C. No 47 581 25ANATURAL GAS (G 20) AND PROPANE (G 31)Tested, certified andservice listedListed by The United Kingdom WaterFitting Byelaws SchemeWITH TIMERRSF 84ET G.C. No 47 581 28ARSF 1OOET G.C. No 47 581 26ANAT …
  • PEERLESS

    PSC II Series

    (40 pages)
    PSCII™BoilersSeriesGasInstallation,Operation &MaintenanceManualAs an ENERGY STAR®Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. …
  • Flexiheat

    R2K 50

    (72 pages)
    R2K 50 - RAD - ING - Manuale - 2107.1_SKM1.3_firm.L224GInstallation, Use and Maintenance Manual for model 0476R2K 50Condensing boiler with integrated heat exchanger for domestic hot water production …

Comments, Questions and Opinions: