Manualios.com

Siemens TC35 Operation & User’s Manual

Siemens TC35 Manual Online:

3.1, 998 votes
Siemens TC35 User Manual
Siemens TC35 User Guide
Siemens TC35 Online Manual

Text of Siemens TC35 User Guide:

  • 34 Compatibility Compatibility withthe predecessor, the M20Terminal The direct predecessor of the TC35 Terminal is the M20 Terminal. The antenna connector is not compatible. The modified version (passive version) of the Votronic handset must be operated at the audio interface in accordance with HH-SI-30.3/V1.1/0. The following table shows the compatibility: Hardwar

  • Siemens TC35, 12 Interface description Purpose of the connectors/connections Use and operation The power supply is implemented by the +- and the GND wire. To switch the TC35 Terminal on, proceed as follows: – Either activate the DTR control line via the RS232 interface – Or connect IGT_IN to +. This connection has already been set up in the specified plug-in power supply unit below, see "Connectible plug-in power supply unit" on page14. Signal name PIN I/O Description Parameters + 1 I Positive supply voltage connection +8V...+30V max. 33V for 1min 2 Free PD_IN 3 I Reset input high active U IH >+5V (>3.5s) U IL <+2V IGT_IN

  • Siemens TC35, 13 Interface description Polarity reversal protection Polarity reversal protection is implemented by means of a power diode. The diode has a reverse voltage of 400V. Overvoltage protection Overvoltages are suppressed by a Zener diode after the polarity reversal protection diode. Fuses A permanently installed, non-replaceable fuse in the TC35 Terminal ensures electrical safety in the event of faults. Connect a fast 1.25A fuse to the supply line of the positive supply voltage for general protection of the Terminal, see "Safety and installation information" on page9.

  • Siemens TC35, 30 Operating states / LED Note: Usually, the network search takes only a fewseconds till the Terminal is registered. If the flashing continues, this means that no SIM card is inserted, no PIN number is entered or no GSM network is available. POWER DOWN Once the operating voltage is applied (+ and GND), the TC35 Terminal is in the POWER DOWN state. The operating voltage for the GSM module is disconnected (the switching regulator is off). In other words, the software of the GSM module is not active. A transition to the POWER DOWN state al

  • Siemens TC35, 21 Interface description The Bootbox BB35 enables software to be updated via the SIM interface. The Bootbox is connected instead of a SIM card (see "Bootbox BB35" on page33). Interference immunity Electrostatic discharge requirements in accordance with ETS 300-342-1 Antenna connector FME (male) A dual band antenna (GSM 900/1800) can beconnected to the RF interface. The connection is implemented as a 50 Ω FME (male) coaxial jack. Antenna connector Purpose of the connectors/connections Outer Inner Signal

  • Siemens TC35, 3 Contents Operating states / LED ........................ 29 POWER DOWN ............................... 30 Network search ............................... 31 Standby............................................ 31 Talk .................................................. 31 AT command control .......................... 32 SW update ........................................... 33 Compatibility ....................................... 34 Compatibility withthe predecessor, the M20Terminal ............................ 34 Certification / maintenance .........

  • Siemens TC35, 31 Operating states / LED Network search (no SIM card, no PIN number, no GSM network) In the network search state, the TC35 Terminal searches for a GSM network. All the components in the GSM Terminal (module) that are not required are shut down in several stages by the energy-saving software. This state is reached: • From the POWER DOWN state: by an active ignition (on) signal at the power supply connection or • From the TALK or STANDBY state: when the network is lost (out of range) Standby In the STANDBY state, the TC35 Terminal is ready to send and receive and registered in

  • Siemens TC35, 10 Installation Mounting kit for top-hat rail installation The TC35 Terminal can be attached to a 35mm top-hat rail using this mounting kit. There are two screws that are used tofix the top-hat rail adapter to the TC35 Terminal. The TC35 Terminal can be inserted onto the top-hat rail using this adapter.

  • Siemens TC35, 25 Interface description Interference immunity • The connecting cable must not exceed 1.8m in length. • Nominal signal range: ±15V • Max. load current 1A • Electrical fast transient burst requirements not specified • Surge immunity requirements not specified • Electrostatic discharge requirements in accordance with ETS 300-342-1 • Immunity RF common mode 0.15–80MHz in accordance with ETS300-342-1 Connectible RS232 connecting cable Item Order no. Supplier RS232 connecting cable 9-pin D-Sub extension 1:1 300574 Tecline Behrener Str. 8 D-66117 Saarbrücken Tel.:+49(0)6819267

  • 8 Features Supplementary services • Phone book • Multiparty • DTMF (Dual Tone Multi Frequency) External interfaces • Connector for plug-in power supply unit • Handset audio interface • Mini-SIM card holder • Antenna connector FME (male) • RS232 interface (V.24/V.28 on the Sub-D socket) Accessories Antennae, SIM cards, power supply units, RS232 cab

  • Siemens TC35, 11 Interface description The following interfaces are available on the TC35Terminal: • Connector for the plug-in power supply unit • Handset connector • Mini-SIM card holder • Antenna connector FME (male) • RS232 interface (V.24/V.28 on the D-Sub socket) Plug-in power supply unit The TC35 Terminal receives its power supply in a wide voltage range (+8 V ... +30 V) via the power supply connectors. Two additional control lines are used for switching the Terminal on/off (resetting). The connection is implemented by a 6-pin Mini- Western connector. Connector for the plug-in power supply unit 3 2 1 4 5 6 1 + 2 free 3 PD_IN 4 IGT_IN 5 free 6

  • Siemens TC35, 6 Product description Highlights • Dual-band EGSM900 / GSM1800 • Data, voice, SMS and fax • R&TTE approval, GCF approval • Easy to integrate • Industrial interfaces • LED display • Wide input voltage range • Highly compact, light and powerful Applications • Fleet management • Teleservice • Security systems • Telematics • Telemetry • Remote monitoring • Remote meter reading • Vending machines

  • Siemens TC35, 7 Features Product data • Dual-band EGSM900 and GSM1800 • Certified in accordance with GSM phase2/2+ • Output performance: – Class 4 (2 W) for EGSM900 – Class 1 (1 W) for GSM1800 • Control via AT commands • Input voltage range +8V ... +30V • Dimensions: 65 x 74 x 33mm • Weight: approx. 130g Certification • R&TTE approval • GCF approval Audio • Half rate (HR) • Full rate (FR) • Enhanced full rate (EFR) SMS • Point-to-point MT and MO • SMS cell broadcast • Text and PDU mode Data • CSD up to 14.4kbps • USSD • Non-transparent mode • V.110, V.32 Fax • Group 3, classe

  • Siemens TC35, 36 Index A Accessories 8 Antenna connector 4, 11, 21 AT command control 32 Audio 7 B Bootbox 33 C Certification 7, 35 Compatibility 34 D Data 7 E External interface 8 F Fax 7 Features 7 Fuses 13 H Handset connector 4, 11, 15 I Installation 9 Interface description 11 L LED 4, 29 M Maintenance 35 Mini-SIM card holder 4, 11 N Network search 31 O Operating state 29 Overview 4 Overvoltage 13 P Package contents / scope of delivery 9 Plug-in power supply unit 4, 11 Polarity reversal 13 Power down 30 Product data 7 Product description 5 R RS232 interface 11, 23 S Safety and installation information 9 Sa

  • Siemens TC35, 32 AT command control The TC35 Terminal is controlled and programmed by means of AT commands. The AT command structure corresponds to the TC35 module used. The AT commands can be obtained from the ICM WM home page: www.siemens.com/wm.

  • Siemens TC35, 2 Contents Safety information ................................ 1 Contents ................................................. 2 Overview ................................................ 4 Front view.......................................... 4 Rear view ........................................... 4 Product description............................... 5 Highlights ........................................... 6 Applications ....................................... 6 Features.................................................. 7 Product data....................................... 7 Certification........................

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Harbor Freight Tools 90980 Assembly & operating instructions harbor-freight-tools/90980-1HO.pdf 27 May 2023 5 2.12 Mb
2 Pfaff select 1520 Instruction manual pfaff/select-1520-4ZN.pdf 06 Oct 2023 82 1.68 Mb
3 Husqvarna Platinum 730 Operation & user’s manual husqvarna/platinum-730-E86.pdf 24 Apr 2023 38
4 SEVERIN RETRACTABLE STYLER 0436 Dimensions severin/retractable-styler-0436-4D8.pdf 31 Jan 2023 1 0.68 Mb
5 Miele HG05 Operating instructions manual miele/hg05-4HJ.pdf 23 Nov 2022 84
6 Sony NW-HD3 Operating instructions manual sony/nw-hd3-9M5.pdf 11 Jun 2023 458 11.9 Mb

Similar Resources:

  • Liquid Controls

    81538

    (12 pages)
    Set-up and Connection GuideAn IDEX Energy & Fuels BusinessLC_IOM_ONTHEGOWIFIADAPTER V1: 05/17L I Q UID C O N T R O L SLC-ON THE GOTM Wireless WiFi AdapterP/N 81538 …
  • Maestro

    100EVO SERIES

    (32 pages)
    MAESTRO 100EVO SERIESQUICK START GUIDE & USER MANUAL REV. 0.8WWW.MAESTRO-WIRELESS.COMEMAIL: [email protected]: 852 2869 0688FAX: 852 2525 4701ADDRESS: ROOM 3603-3609, 36/F, 118 CONNAUGHT ROAD WEST, SHEUNG WAN, HONG KONG …
  • Edimax

    AR-7025Um

    (2 pages)
    USB ADSL ModemUSB ADSL ModemUSB ADSL Modem USB ADSL Modem Provides Panda Platinum for system anti virusProvides Panda Platinum for system anti virusAR-7025UmADescriptionsAR-7025UmA USB-ADSL Modem is an external ADSL modem connecting broadband ADSL line to USB connector of PC system.AR-7025UmA uses advanced ADSL chipset solution with complete set of industry …
  • Sierra Wireless

    306

    (24 pages)
    AirCard® USB 306/307 MODEMAirCard® USB 308/309 MODEMAirCard® 310U MODEMwww.sierrawireless.comQUICK START GUIDEGUIDE DE DÉMARRAGE RAPIDEGUÍA DE INICIO RÁPIDO …
  • NETGEAR

    CM400

    (2 pages)
    Quick StartHigh Speed Cable ModemModel CM400Package ContentsCable modemEthernet cable Power adapterCoaxial cable(not included)Power adapterCable modemEthernet cableAttachable feet4. Connect the power adapter.Connect the power adapter to the cable modem and plug the power adapter into an electrical outlet.When the startup procedure is completed, the Power LE …
  • TC Communications

    TC1631R

    (22 pages)
    Notice!Although every effort has been made to insure that this manual is currentand accurate as of date of publication, no guarantee is given or impliedthat this document is error free or accurate with regard to any specifica-tion. TC Communications, Inc. reserves the right to change or modifythe contents of this manual at any time without prior notificatio …

Comments, Questions and Opinions: