Manualios.com

Arctiko SUF 100 Operating Instructions Manual

Arctiko SUF 100 Manual Online:

3.6, 2560 votes
Arctiko SUF 100 User Manual
Arctiko SUF 100 User Guide
Arctiko SUF 100 Online Manual

Text of Arctiko SUF 100 User Guide:

  • Arctiko SUF 100, 2 INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE Before using the freezer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safeguarding the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Precautions and general recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operating instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 3 IMPORTANT Before using the freezer For safety reasons, the instructions should be read before the freezer is commissioned. The operating instructions should always be available to the personnel! Only use the freezer for its specific purpose. Safeguarding the environment 1. Packing The packing material is entirely recyclable and marked with recycling symbol. Please follow the local re

  • Arctiko SUF 100, 4 Operating Instructions: Ultra Low Temperature Freezing Box For safety reasons, these operating instructions should be read before the freezer is commissioned. The operating instructions should always be available to the personnel! The drawings and symbols in these operating instructions are for safety purposes when commissioning and using the freezer. Instruct the personnel in the use of the freezer (Can be down to -117°F). There is a risk of frost-bite if the contents or the sides of the inner container are touched! In the event of breakdown or irregularities contact professional instructors or r

  • Arctiko SUF 100, 5 Warning: Regulations require that this appliance must be earthed The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the above procedures and reminders. If the socket and plug are not of the same type, please have the plug or socket replaced by a qualified electrician. Do under no circumstances use extension leads or adaptors. 1. The freezer should be connected by an authorised electrician or by the company, which sold the freezer! Incorrect installation may damage the freezer. 2. Pl

  • 6 CONTROL PANEL (Dixell XR30CX Controller) SET: To display target set point; in programming mode it selects a parameter or confirm an operation. (DEF): To start a manual defrost (UP): To see the max. stored temperature; in programming mode it browses the parameter codes or increases the displayed value. (DOWN): To see the min stored temperature; in programming mode it browses the par

  • Arctiko SUF 100, HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED 1. Hold press the SET key for more than 3s, while the max. or min temperature is displayed. (rSt message will be displayed) 2. To confirm the operation the “rSt” message starts blinking and the normal temperature will be displayed. MAIN FUNCTIONS HOW TO SEE THE SETPOINT 1. Push and immediately release the SET key: the display will show the Set point value; 2. Push and immediately release the SET key or wait for 5 seconds to display the probe value again. 1. Push the SET

  • Arctiko SUF 100, 8 3. Select the required parameter. 4. Press the “SET” key to display its value. 5. Use or to change its value. 6. Press “SET” to store the new value and move to the following parameter. To exit: Press SET + or wait 15s without pressing a key. NOTE1: if none parameter is present in Pr1, after 3s the “noP” message is displayed. Keep the keys pushed till the Pr2 message is displayed. NOTE2: the set value is stored even when the procedure is exited by waiting the time-out to expire. 6.6.2 HOW TO MOVE A PARAMETER FROM THE HIDDEN MENU TO THE FIRST LEVEL AND VICEVERSA. Each parameter present in the HIDDEN MENU can be removed or put into

  • Arctiko SUF 100, 9 PARAMETERS DISPLAY DEFROST REGULATION Hy Differential: (0,1 ÷ 25,5°C / 1÷255 °F) Intervention differential for set point. Compressor Cut IN is Set Point + differential (Hy). Compressor Cut OUT is when the temperature reaches the set point. LS Minimum set point: (-100°C ÷ SET; [-148F ÷ SET): Sets the minimum value for the set point. US Maximum set point: (SET÷150°C/ SET÷302°F). Set the maximum value for set point. Ot Thermostat probe calibration: (-12.0÷12.0°C; -120÷120°F) allows to adjust possible offset of the thermostat probe. OdS Outputs activation delay at start up: (0÷255min) Th

  • Arctiko SUF 100, 10 ALARMS ALARM RELAY MANAGEMENT DIGITAL INPUT ALC Temperature alarms configuration: (Ab; rE) Ab= absolute temperature: alarm temperature is given by the ALL or ALU values. rE = temperature alarms are referred to the set point. Temperature alarm is enabled when the temperature exceeds the “SET+ALU” or “SET-ALL” values. ALU MAXIMUM temperature alarm: (SET÷150°C; SET÷302°F) when this temperature is reached the alarm is enabled, after the “ALd” delay time. ALL Minimum temperature alarm: (-100.0 ÷ SET°C; -148÷302°F) when this tempera

  • Arctiko SUF 100, 11 nPS Pressure switch number: (0 ÷15) Number of activation of the pressure switch, during the “did” interval, before signalling the alarm event (I2F= PAL). If the nPS activation in the did time is reached, switch off and on the instrument to restart normal regulation. odc Compressor status with door open: no, Fan = normal; CPr; F_C = Compressor OFF. rrd Outputs restart after doA alarm: no = outputs not affected by the doA alarm; yES = outputs restart with the doA alarm; HES Temperature increase during the Energy Saving cycle: (-30,0°C÷30,0°C/-22÷86°F) it sets the increasing value of the set point during

  • Arctiko SUF 100, 12 START DEFROST (i1F = dFr) It starts a defrost if there are the right conditions. After the defrost is finished, the normal regulation will restart only if the digital input is disabled otherwise the instrument will wait until the “MdF” safety time is expired. INVERSION OF THE KIND OF ACTION: HEATINGCOOLING (i1F = Htr) This function allows to invert the regulation of the controller: from cooling to heating and viceversa. ENERGY SAVING (i1F = ES) The Energy Saving function allows to change the set point value as the result of th

  • Arctiko SUF 100, 15 Service with Ep88 for - 83°C degree boxes: Note that the EP-88 gas can only be filled from a bottle containing a measured amount. Normal procedures used in conjunction with other refrigerants cannot be used. Furthermore note that the freezing capability is very dependent upon filling the entire contents of the bottle into the system. Freezing capability is also very dependent upon the temperature of the EP88 and whether it has been still for a long period of time. The temperature of the service bottle must be between 8 and 14 degrees, and the contents must be mixed by shaking the bottle 10-15 times. In order to carry out the service procedure correctly, it is necessary to use

  • 16 Description of changing the lid gasket Tools and materials needed for the change Screwdriver (if possible electric), knife (keen), screws with flat head and a new gasket. 1. The old gasket is cut off as close to the lid as possible. 2. The new gasket is placed on the table with the underneath of the gasket up. The loose fold which is up is cut off. Beware not to damage the rest

  • Arctiko SUF 100, Cleaning and maintenance of the freezer 1. Ice will form on the sub lids in the freezer. This ice should be removed with a scraper at regular intervals. (Remember safety gloves). 2. Ice on the inside of the box should be removed as required, as it reduces the cooling capacity! Take the contents out of the freezer. Pull out the plug and leave the lid open until the ice can be removed. (Remember safety gloves). 3. Dry the inner container with a cloth until it is not damp any longer! 4. Clean the outside of the freezer with a damp cloth. Be careful not to get damp (

Related Products and Documents (Freezer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sylvania SMPK2066 Operation & user’s manual sylvania/smpk2066-VPB.pdf 27 May 2023 42
2 TSI Instruments 9555 Series Operation and service manual tsi-instruments/9555-series-M12.pdf 08 Oct 2023 22
3 Char-Griller 3008 Owner's manual char-griller/3008-6YB.pdf 30 Mar 2024 34 1.1 Mb
4 Jenn-Air JUD278DBCX00 Installation instructions manual jenn-air/jud278dbcx00-8LO.pdf 12 Aug 2022 32
5 Daikin FXHQ-A Technical data manual daikin/fxhq-a-U64.pdf 12 Dec 2022 21
6 LG HX806PH Owner's manual lg/hx806ph-D51.pdf 17 Sep 2023 62

Similar Resources:

  • Phcbi

    MDF-DU901VHL Series

    (64 pages)
    MDF-DU901VHLSeriesPlease read the operating instructions carefully before using this product, and keep the operating instructions for future use. See page 62 for all model numbers. Operating Instructions Ultra-Low Temperature Freezer …
  • montpellier

    MON-MS148W

    (19 pages)
    Installation and Operating Instructions MODEL: MON-MS148W COMBI FRIDGE FREEZER A+ (Picture shown for indicative purposes only, model supplied may differ) Please read these instructions carefully before attempting to install or use this appliance. It is advisable to keep these instructions in a …
  • Whirlpool

    B2lDK

    (24 pages)
    A Note To You 2 Important Safety Instructions 3 Parts And Features 4 Before Using Your Refrigerator 5 Using Your Refrigerator 7 Ci71$;eFspr 17 Food Storage Guide 20 If Yqu Need es: 22 Warranty 24 1-800-253-1301 Cdl us w’kh questhns of comments. NO-FROST REFRIGERATOR-FREEZER MODEL EB2lDK …
  • Summit

    FS-62L

    (2 pages)
    FS62L 33.5" x 23.63" x 23.5" (H x W x D)Freestanding counter height all-freezer capable of -25°Coperation with front-mounted lockHighlights:Factory-installed lock provides security you can count onConvenient dimensions for easy placement in tight locationsCapable of operating at -25°C for long-term food preservation Seamless interior line …
  • Antec

    HD Cooler

    (1 pages)
    www.antec-inc.com 1-800-22ANTEC +31 (10) 462-2060Aluminum alloy heatsink. ABS and PC fire resistant front panelUPC# 761345-75011-05Your Hard Drive works hard. So let it chill.Today's hard drives regularly reach speeds that'd make Captain Kirk proud. But all that speed generates quite a bit of dangerous heat. So prote …
  • Samsung

    Refrigerator

    (40 pages)
    Refrigeratoruser manualimagine the possibilitiesThank you for purchasing a Samsung product.EnglishFree Standing ApplianceThis manual is made with 100 % recycled paper.DA68-02916A (EN)-07.indd 01DA68-02916A (EN)-07.indd 01 2014. 5. 19.  2:062014. 5. 19.  2:06 …

Comments, Questions and Opinions: