Manualios.com

artisan TurboStacK AT-TS06F Installation Manual

  • TurboStacK AT-TS06F Network Router
  • ma1uk/QI841Po
  • Installation Manual
  • PDF / Adobe Acrobat Reader
  • 97

artisan TurboStacK AT-TS06F Manual Online:

4.5, 1800 votes
artisan TurboStacK AT-TS06F User Manual
artisan TurboStacK AT-TS06F User Guide
artisan TurboStacK AT-TS06F Online Manual

Text of artisan TurboStacK AT-TS06F User Guide:

  • artisan TurboStacK AT-TS06F, Hardware Installation 14 Note When inserting or removing repeater modules (using the hot swapping method), you must be sure that the power cord is plugged in. To enable hot swapping, you must disconnect the module from the backplane before you unplug the power cord. 4. Flip open (toward you) the two plastic doors on either side of the repeater front panel. (See Figure 9 below.) 5. Align the guide rails on either side of the module with the grooves in the chassis slot. Then, slide the module into the chassis without seating it in the backplane conn

  • artisan TurboStacK AT-TS06F, 75 Appendix E Technical Support Fax Order Name___________________________________________________________________ Company ________________________________________________________________ Address _________________________________________________________________ City ____________________State/Province____________ Zip/Postal Code __________ Country _______________________ Phone______________________Fax _________ Incident Summary Model number of ATI product I am using___ ___________________________________ Firmware r

  • Hardware Installation 12 Installing Hubs This section contains two separate procedures for installing manageable TurboStack hubs: ❑ Standalone installation ❑ Installation in a chassis Installing a standalone hub The following procedure details how to install a TurboStack hub in a standalone configuration: 1. Plug one end of the power cord into the repeater�

  • artisan TurboStacK AT-TS06F, 53 Chapter 9 AT-TS24TR Connectivity AT-TS24TR Modules The AT-TS24TR has 24 10BASE-T ports represented by 24 RJ45 connectors for UTP. The ports are double stacked, in two rows of 12 ports each. Figure 50 shows the AT-TS24TR faceplate; the following section describes the connectors. For information about UTP wiring, refer to Appendix A. Figure 50: AT-TS24TR Faceplate MDI/MDI-X switch 24 RJ45 Port activity LEDs connectors Plastic door/handles Artisan Technology Group - Quality Instrumentation ... Gua

  • TurboStack Hubs with Management 83 AT-TS12FS/SM 1 AT-TS12FS/SMA 4 AT-TS12FS/ST 4 AT-TS12T 3, 43, 44, 64 AT-TS12TR 3, 47, 48 AT-TS24 44, 61 AT-TS24T 3, 49, 50, 64 AT-TS24TR 3, 53, 54, 55 AT-TS24TRS 1, 4 AT-TS24TS 1, 4 AT-TS90TR 6 AT-TS95T 6 AT-TSA1 18 AT-TSA2 18 AT-TSA3 18 AT-TSA5 18 AT-TSA8 18 AT-TSA9 18 backup 6, 25 functions 6 hot swapping 3 master 6, 12, 25 slave 1 slaves 6 N network

  • artisan TurboStacK AT-TS06F, 43 Chapter 6 AT-TS12T Connectivity AT-TS12T Modules The AT-TS12T has 12 10BASE-T ports incorporated in a Telco 50-pin (RJ21) connector for UTP. Figure 41 shows the AT-TS12T faceplate; the following section describes the Telco connector. For general information about UTP wiring, see Appendix A. Figure 41: AT-TS12T Faceplate RJ21 connector Port activity LEDs Plastic door/handles Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

  • artisan TurboStacK AT-TS06F, TurboStack Hubs with Management 19 Network Appliqué Installation In a TurboStack department concentrator chassis, you can connect manageable hubs to network zones using different cable media by installing different appliqués. Location of Appliqué Port To install or remove an appliqué, find the TurboStack hub appliqué port. As shown in Figure 12, this port is located directly to the left of the RS232 terminal port on the module faceplate (in this case an AT-TS06F/SC model hub). The appliqué port is convertible on all TurboStack hubs with management. You may reconfigure it by installing an alternative to the AUI network-interface appliqué as described bel

  • TurboStack Hubs with Management 35 If you are installing a coaxial cable segment without a BNC-T connector at the end (as shown in Figure 32), you must enable the termination of the port by turning the 50 Ω termination switch ON (1). Port Status Indicators The port status indicators on the AT-TS08 hubs’ front panels provide visual diagnostic and activity information for network a

  • UTP Reference 58 UTP Hub-to-MAU Wiring Figure 54 shows a UTP cable with an RJ45 connector. For a 10BASE-T link between a hub and a Medium Attachment Unit (MAU) or Network Interface Controller (NIC), the cable is wired straight-through. That is, an RJ45 receptacle at the hub would wire pin-to-pin to the RJ45 receptacle at the MAU, as shown in Figure 55. Figure 54: RJ45

  • artisan TurboStacK AT-TS06F, 65 Appendix C IEEE 802.3 Quick Primer 10BASE-T 10BASE-T UTP media were implemented to reduce Ethernet wiring costs. UTP wiring is installed in most buildings for telephone systems. Make sure the UTP wiring used for 10BASE-T is able to carry the high Ethernet data rates before you implement a 10BASE-T network solution. Unlike coaxial Ethernet, 10BASE2 and 10BASE5, 10BASE-T UTP is point-to-point wiring. Typically, one end is connected to an Ethernet 10BASE-T NIC or transceiver (MAU) and the other end is connected to a 10BASE-T hub (

  • artisan TurboStacK AT-TS06F, vii Emisión RFI EN55022 Clase A ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. Inmunidad EN50082-1 Seguridad eléctrica EN60950, UL1950, CSA 950 Este es un "PRODUCTO DE DIODO LUMINISCENTE (LED) CLASE 1" SEGURIDAD AVISOS ELECTRICOS ADVERTENCIA: PELIGRO DE ELECTROCHOQUE Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un t

  • artisan TurboStacK AT-TS06F, TurboStack Hubs with Management 7 Chassis Options ATI offers a variety of desktop and rackmount chassis. These chassis are available with either standard or segmented backplane configurations. Chassis with Standard Backplane An ATI chassis equipped with a standard backplane can hold up to a maximum of eight TurboStack hubs connected through the standard backplane mounted in the inside back wall of the chassis. Figure 3 shows ATI’s 8-slot chassis with fans and standard backplane. Figure 3: 8-slot Chassis with Standard Backplane Standard backplane Artisan Technology Group - Quality Instrumentation ... Guarant

  • artisan TurboStacK AT-TS06F, TurboStack Hubs with Management 41 Figure 39 shows the threaded SM connectors. Port Indicators The port indicators and corresponding symbopls on the AT-TS12F/ST, SC, SM Series repeater front panels provide visual diagnostic and activity information for network analysis (see Figure 40). Each fiber optic port supports the following indicator functions with one dual-color front panel LED per port. GREEN LINK—Steady illumination indicates that the port has a valid link and is not partitioned. GREEN RECEIVE—Flashing illumination indicates

  • artisan TurboStacK AT-TS06F, AT-TS12TR Connectivity 48 RJ45 Connectors The AT-TS12TR uses 12 RJ45 connectors, thus eliminating the need for a Telco-type cabling adapter. Figure 45 shows a sample RJ45 connector. Port Indicators The port indicators on the AT-TurboStack hub front panels provide visual diagnostic and activity information for network analysis. The AT-TS12TR provides a central bank of indicators for box-level monitoring. As shown in Figure 46, each 10BASE-T port supports the following indicator functions with one single-color front pan

  • artisan TurboStacK AT-TS06F, 11 Chapter 2 Hardware Installation Site Preparation Attention Improper installation of the chassis can expose personnel to high voltages, risking the possibility of injury or death. Before installing TurboStack hubs, read the See Electrical Safety and Installation Requirements on page i. Location A TurboStack hub can operate as a standalone product, or installed in a chassis or in a 19-inch rack. Ventilation The site must have adequate ventilation to provide an operating environment consistent with TurboStack specifications. Hubs have internal fans to aid in cooling. Chassis models are also equipped with fans. For the fans to func

  • artisan TurboStacK AT-TS06F, lxxxvii TurboStack Hubs with Management 3 TurboStack Hubs without Management 4 ATI Network Port Appliqués 18 ATI Micro Transceivers 18 AT-TS06F Hubs with Management 27 AT-TS12F Series Hubs with Management 37 Usable and Unusable Twisted Pair Cable 57 50-Pin Telco Pin-Out 62 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

  • artisan TurboStacK AT-TS06F, AT-TS24TR Connectivity 56 GREEN LINK (Solid Green)—This indicates that the particular port has a valid link and is not partitioned. GREEN RECEIVE (Flashing Green)—When a port’s LED is blinking, the port is receiving Ethernet packets. AMBER PARTITION (Steady Amber)—A steady amber port indicator means the port is partitioned or segmented from the rest of the ports. This partitioning may be associated with a management function or with an error condition on the link. AMBER COLLISION (Flashing Amber)—A momentary amber flash occurs when a collision is detected on the port. NO LINK (No Light)—If the Link Test functio

  • artisan TurboStacK AT-TS06F, TurboStack Hubs with Management 15 10. Secure the module in the chassis slot by screwing the module in place (see Figure 9). Then, snap closed the plastic doors. 11. Connect your data cables to the hub and the network. Check the Link indicators. 12. If one or more of the ports on the module are transferring data, the Receive indicator will illuminate. 13. The module is now active in the chassis as a component of a network concentrator. For confirmation, you can obtain hub and port status information via network management. To enable management from

  • artisan TurboStacK AT-TS06F, AT-TS08 Connectivity 36 Terminator Switch Figure 33 shows the location of the 50 Ω Terminator switch included with each BNC port receptacle: 0 = Terminator disabled—Use the OFF position if you are installing a coaxial cable segment with a BNC-T connector on this port (see Figure 31). 1 = Terminator enabled—Use the ON position if you are installing a coaxial cable segment without a BNC-T connector at this port and the unit is at the end of the cable (see Figure 31). This is the default switch position.

  • artisan TurboStacK AT-TS06F, 77 Appendix F TurboStack™ Manual Feedback Please tell us what additional information you would like to see discussed in the manual. If there are topics you would like information on that were not covered in the manual, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn International (ATI). The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of the manual. On a scale of 1 to 10 (10 being most important), rate the importance of the

  • Hardware Installation 20 2. Detach the AUI appliqué assembly from the hub faceplate by loosening the two M3x6 flat-head screws to the far right and left on the connector plate, shown in Figure 13. Note Do not unscrew the AUI slide kit screws that secure the AUI connector to the appliqué plate until the entire appliqué assembly (i.e., AUI connector, connector plate, and

  • artisan TurboStacK AT-TS06F, Glossary 72 LINK TEST—In 10BASE-T Ethernet, there is a link test function that validates the UTP link. This consists of a pulse transmitted from point A on one pair that is validated at point B. Point B also transmits a pulse on the second pair to be validated by point A. These pulses occur during media idle states (in between packets). MANAGED MODULE— An intelligent repeater in a department concentrator chassis that makes management data available to the Master. MANAGEMENT AGENT—Software that is used to view hub activity and set hub

  • artisan TurboStacK AT-TS06F, iv SECURITE INFORMATION SUR L’ELECTRICITE AVERTISSEMENT: DANGER D’ELECTROCUTION Pour empêcher les dangers d’ELECTROCUTION, ne pas enlever le couvercle. L’équipement ne contient aucun élément réparable par l’utilisateur. Cet appareil comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ELECTROCUTION, débrancher l’appareil de la prise de courant avant de connecter ou de déconnecter les câbles LA

  • artisan TurboStacK AT-TS06F,  Copyright 1996 Allied Telesyn International All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International. Allied Telesyn International reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International be liable for any incidental, special, indirect, or consequential damages whatsoever, including

  • artisan TurboStacK AT-TS06F, i Electrical Safety and Installation Requirements RADIATED ENERGY U.S. Federal Communications Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Minolta K-QM-3501E - PART 3 Manual  minolta/k-qm-3501e-part-3-523.pdf 05 Apr 2023 5
2 Hach 2100A Operation & user’s manual hach/2100a-QL6.pdf 02 Sep 2022 96 1.68 Mb
3 Eaton Char-Lynn 110 Repair manual eaton/char-lynn-110-WH7.pdf 24 Jul 2022 12 0.42 Mb
4 Frigidaire FRT15B1B Factory parts catalog frigidaire/frt15b1b-UY7.pdf 02 Feb 2023 11
5 Epson PhotoPC L-400 Owner's manual epson/photopc-l-400-4O8.pdf 12 Jul 2023 65 9.96 Mb
6 Zebra DA402 Operation & user’s manual zebra/da402-5O6.pdf 23 Nov 2023 56 1.17 Mb

Similar Resources:

  • NETGEAR

    FVS124G - ProSafe VPN Firewall 25

    (238 pages)
    202-10085-01, March 2005202-10085-01 March 2005NETGEAR, Inc.4500 Great America Parkway Santa Clara, CA 95054 USAReference Manual for the ProSafe VPN Firewall 25 with 4 Gigabit LAN and Dual WAN Ports FVS124G …
  • eWON

    eWON Flexy

    (40 pages)
    support.ewon.bizeWON Flexy - Base UnitsThis installation guide describes the hardware of the eWON Flexy - Base Unit and explains how to get started with the embedded web site.Installation GuideIG 014 / Rev. 1.5 …
  • Fortinet

    FortiGate-5000

    (77 pages)
    FortiGate-5000 Series Introduction01-30000-83466-20090108FAN TRAY FAN TRAYFAN TRAY13119753124681012145140CRITICALRESETMAJORMINORUSER1USER2USER35140SAPSERIAL 1 SERIAL 2 ALARMFILTER1201210/100link/ActETH0ServiceRESETSTATUSHot Swaplink/ActETH0ETH110/1005000SM10/100link/ActETH0ServiceRESETSTATUSHot Swaplink/ActETH0ETH110/1005000SMPSU APSU BCONSOLEACTACTLINKLINKF …
  • Accton Technology

    ES3005

    (2 pages)
    Key BenefitsProduct OverviewHigh-speed 10/100Mbps switching for your desktopThis legendary Edge-Core 5-port and 8-Port Switchs can significantly increase your speed of network traffic. A switch serves the same function as a hub in a network- tying your network equipment together. However unlike a simple-minded hub that divides the network's bandwidth am …
  • peplink

    Pepwave MAX HD2 IP67

    (3 pages)
    Installation recommendationPole Mountwww.peplink.com©Peplink. All rights reserved.HD2 IP67Steps:1. Align the mounting unit to the pole. Place the two semicircular connectors through the corresponding holes in the mounting unit. 2. Attach a washer and nut to each end of the semicircular connectors to secure it to the mounting unit.3. Place the device on the …
  • Silver Spring

    Bridges NIC 42

    (14 pages)
    Silver Spring Networks555 Broadway StreetRedwood City, CA 94063www.silverspringnet.comBridges NIC 42 User Guide 18 March 2013 Silver Spring Networks 1Bridges NIC 42 User Guide …

Comments, Questions and Opinions: