Manualios.com

American Standard 2A7A3018-060A Installer's Manual

American Standard 2A7A3018-060A Manual Online:

3.7, 2601 votes
American Standard 2A7A3018-060A User Manual
American Standard 2A7A3018-060A User Guide
American Standard 2A7A3018-060A Online Manual

Text of American Standard 2A7A3018-060A User Guide:

  • American Standard 2A7A3018-060A, © 2009 American Standard Heating & Air Conditioning Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice. 11-AC18D1-4 These instructions do not cover all variations in systems nor provide for every possible contingency to be met in connection with installation. All phases of this installa- tion must comply with NATIONAL, STATE AND LOCAL CODES. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter sho

  • American Standard 2A7A3018-060A, PAGE 2 Pub. No. 11-AC18D1-4 INSTALLER'S GUIDE 7. If outdoor unit is mounted above the air handler, maximum lift should not exceed sixty (60) feet (suction line). If air handler is mounted above condensing unit, maximum lift should not exceed sixty (60) feet (liquid line). 8. Locate and install indoor coil or air handler in accordance with instruction included with that unit. NOTE: Refer to “Refrigerant Piping Software” Pub. No. 32-3312-0*, and “Refrigerant Piping Manual” Pub. No. 32-3009-0* (the position of the * denotes latest revision number). C. INSTALLING REFRIGERANT LINES ▲ C A U TI O N: If using existing refriger

  • American Standard 2A7A3018-060A, Pub. No. 11-AC18D1-4 PAGE 3 INSTALLER'S GUIDE 3. Cut and fit tubing, minimizing the use of sharp 90° bends. 4. Insulate the entire gas line and its fittings. 5. Do NOT allow uninsulated liquid line to come in direct contact with bare gas line. 6. Precautions should be taken to avoid heat damage to the pressure tap valve core during brazing. It is recom- mended that the pressure tap port valve core be removed and a wet rag wrapped around the valve body. NOTICE: Use care to make sure that no moi

  • American Standard 2A7A3018-060A, PAGE 4 Pub. No. 11-AC18D1-4 INSTALLER'S GUIDE 11. The gas valve can now be opened. For a ball type gas valve, open the gas valve by removing the shut-off valve cap and turning the valve stem 1/4 turn counterclockwise, using 1/4" Open End or Adjustable wrench. See Figure 4. For brass gas line service valve opening, follow 9 and 10 above. See Figure 5. 12. The gas valve is now open for refrigerant flow. Replace valve stem cap to prevent leaks. Again, these caps MUST BE REPLACED to prevent leaks. Replace valve stem and pres- sure tap cap finger tight, then tighten an additional 1/6 turn. See Figure 4. If refrigerant lines are longer than 15 fee

  • American Standard 2A7A3018-060A, Pub. No. 11-AC18D1-4 PAGE 5 INSTALLER'S GUIDE TYPICAL FIELD WIRING DIAGRAMS Notes: 1. Be sure power supply agrees with equipment nameplate. 2. Power wiring and grounding of equipment must comply with local codes. 3. Low voltage wiring to be No. 18 AWG minimum conductor. 4. ODT-B must be set lower than ODT-A. 5. If outdoor thermostats (ODT) are not used, connect W1 to W2 and W3. 6. N/A to programmable thermostat. LEGEND FACTORY WIRING FIELD WIRING

  • PAGE 6 Pub. No. 11-AC18D1-4 INSTALLER'S GUIDE R-22 SUBCOOLING CHARGING TABLE LIQUID TEMP. (°F) DESIGN SUBCOOLING VALUES (°F) 8101214 LIQUID LINE PRESSURE (psi) 45 89 93 96 100 50 98 102 105 109 55 107 111 115 119 60 117 121 126 130 65 128 132 137 141 70 139 144 148 153 75 151 156 161 166 80 163 168 174 179 85 176 182 187 193 90 190 196 202 208 95 205 211 217

  • Pub. No. 11-AC18D1-4 PAGE 7 INSTALLER'S GUIDE From Dwg. 21D152862 Rev. 18 2A7A3 OUTLINE DRAWING NOTE: ALL DIMENSIONS ARE IN MM (INCHES). MODELS BASE FIG. A B C D E F G H J K 2A7A3018A 2 2 651 (25-5/8) 724 (28-1/2) 651 (25-5/8) 5/8 1/4 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18) 2A7A3024A 2 2 832 (32-3/4) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 137 (5-3/8) 65 (2-

  • American Standard 2A7A3018-060A, Pub. No. 11-AC18D1-4 02/09 INSTALLER'S GUIDE Technical Literature - Printed in U.S.A. American Standard Heating & Air Conditioning Troup Highway Tyler, TX 75707 8. Supply registers and return grilles open and unobstructed ................................................... [ ] 9. Return air filter installed .................................................. [ ] 10. Thermostat thermometer is accurate. Check against a reliable thermometer. Adjust per instructions with thermostat ........................... [ ] 11. Is correct speed tap being used? (Indoor blower motor)...................................................... [ ] 12. Operate complete system in each mode to insure safe

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weslo Cadence 4200 Manual  weslo/cadence-4200-JYC.pdf 19 Sep 2022 16 0.29 Mb
2 Toshiba SD-5109U Owner's manual toshiba/sd-5109u-952.pdf 12 Mar 2023 48 3.71 Mb
3 ClearSounds QLINK Operation & user’s manual clearsounds/qlink-16Y.pdf 11 Dec 2022 8 0.23 Mb
4 Kenwood DNX7230DAB Quick start manual kenwood/dnx7230dab-9R7.pdf 25 Nov 2023 36
5 Samsung UN46ES7500 E- E-manual samsung/un46es7500-e-5SK.pdf 07 Feb 2023 83 6.44 Mb
6 VOLTA U3410 Directions for use manual volta/u3410-3M7.pdf 21 Jul 2022 16 1.29 Mb

Similar Resources:

  • Panasonic

    S-36PU1E5

    (440 pages)
    TECHNICAL DATA&SERVICE MANUAL85464849311002REFERENCE NO. SM830211-02R410A ModelsModel No.Indoor UnitsTypeIndoor Units Type36 45 50 60 71 100 125 140U14-Way CassetteS-36PU1E5 S-45PU1E5 S-50PU1E5 S-60PU1E5 S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5Y14-Way Cassette 60×60S-36PY1E5 S-45PY1E5 S-50PY1E5–– – – –T1 CeilingS-36PT1E5 S-45PT1E5 S-50PT1E5 …
  • LG

    RAD-183A

    (42 pages)
    LG RoomAir ConditionerSERVICE MANUALLGMODEL: WG1805RY6,RAD-183AWG2405RY6,RAD-243ACAUTIONwebsite http://www.lgservice.com• BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.• ONLY FOR AUTHORIZED SERVICE PERSONNEL. …
  • Samsung

    SGH-i300

    (255 pages)
    Please read this manual before operating your phone, and keep it for future reference.SmartphoneSGH-i300User’s GuideWorld Wide Webhttp://www.samsungmobile.com …
  • Pfannenberg

    DTS 8000E Series

    (53 pages)
    外挂式机柜空调操作及使用说明书 DTS 8000E 50/60Hz 系列 Operating and assembly instruction For side-mounted cooling units DTS 8000E 50/60Hz …
  • Samsung

    AS09F Series

    (22 pages)
    ENGLISHSplit-type Room Air Conditioner (Cool)FRANÇAISAS09F SeriesAS12F SeriesAS18F SeriesAS24F SeriesAS09N SeriesAS12N SeriesAS18N SeriesAS24N SeriesUSER’S MANUALAE DB98-28664A(2)DB98-26506A(1)-E.indd 23 2007-11-8 13:13:53 …
  • Daikin

    FTX09AXVJU

    (64 pages)
    INSTALLATION MANUALR410A SPLIT SERIESInstallation ManualR410A Split SeriesEnglishManual de instalaciónSerie Split R410AEspañolManuel d’installationSérie split R410AFrançaisDAIKIN ROOM AIR CONDITIONERMODELSFTX09AXVJUFTX12AXVJUFTX18AXVJUFTX24AXVJURX09AXVJURX12AXVJURX18AXVJURX24AXVJUFTK09AXVJUFTK12AXVJUFTK18AXVJUFTK24AXVJURK09AXVJURK12AXVJURK18AXVJURK24AX …

Comments, Questions and Opinions: