  • Table for battery cable diameter corresponding to capacity of UPS UPS capacity Battery cable diameter (mm 2 ) 10KVA 5.5mm 2 15KVA 8mm 2 22.5KVA 14mm 2 30KVA 14mm 2 45KVA 30mm 2 60KVA 50mm 2 80KVA 60mm 2 100KVA 80mm 2 120KVA 125mm 2 150KVA 150mm 2 200KVA 200mm 2 250KVA 250mm 2 Table 4-2-5

  • OPTI-UPS DS-C33 Series, After wiring, please check the following points listed below. (1) Screws in each point are tight. (2) Ground wire is connected well. (3) No short-circuit in the output switch board and load circuits. (4) Battery fuse switch S4 in switched off. (5) Batteries are connected correctly. (6) All switches of the UPS from S1 to S6 are off. 4-2-4 Precaution for grounding system The grounding mode is divided into 4 categories: (1) Equipment grounding: used in low voltage equipment, grounding by non-charged me

  • OPTI-UPS DS-C33 Series, SYSTEM SET Basic set User set (C-1) Please Enter Security Code **** USER SET 1 Alter security NO. 2 Battery test 3 Communication set 4 F. V. C/C set 5 Other set Security code Error NO YES (C-3)

  • 8-3 Simple troubleshooting for system function Error message displayed Description Troubleshooting (1)No battery found Add battery (2)Battery power is insufficient Recharge battery (3)Ol-3302 detects circuit error Replace ol-3302 Battery can’t supply power (4)Ol-3300 program parameter inaccuracy Correct program parameter (1)Utility voltage is too lo

  • OPTI-UPS DS-C33 Series, (A-1) I/P V RS 000.0V RN 000.0V ST 000.0V SN 000.0V TR 000.0V TN 000.0V I/P Freq . : 00.0 HZ I/P I I/P Cap. RN 000.0A 000.00KVA SN 000.0A 000.00KVA TN 000.0A 000.00KVA Total Cap. : 000.00KVA O/P V RS 380.0V RN 220.0V ST 380.0V SN 220.0V TR 380.0V TN 220.0V O/P Freq. : 60.0Hz O/P I O/P Cap. RN 000.0A 000.00KVA SN 000.0A 000.00KVA TN 000.0A 000.00KVA Total Cap. : 000.00KVA O/P POWER R 000.00KW S 000.00KW T 000.00KW Total Power 000.00 KW Load Cap. : 000.00 % (A-2-1) (A-2-5) (A-2-2)

  • OPTI-UPS DS-C33 Series, 2-3-2 Introduction to inverter module (1) Uses IGBT as power component. (2) Uses high technology DSP to control the inverter module. (3) Utilize digital control management to prevent discrete component from aging, temperature slant and reduce the quantity of parts to enhance system reliability. (4) Integrated A/D signal processing, 12bit resolution and high speed transferring capability. (5) Reserve communication port for parallel UPS operation, detection of secondary power, ATS control signal, SPWM testing port. (6) Highly integrated

  • OPTI-UPS DS-C33 Series, EPO 2-3-4 Input start up/protect trigger (1) Start up function. This function is used for delaying the input power during start up or utility recovery to protect the unit from electrical surge impact. The function is controlled by the main control board. (2) Protection function. This function is used whenever input voltage is too high or too low or wrong phase sequence or if one phase is missing. In this case, the input trigger will be cut to protect the unit. This function is controlled and detected by main control board. 2-3-5 EPO switch (Emergency Power Off) (1) EPO (Emergency Power Off) is a device for shutting down t

  • OPTI-UPS DS-C33 Series, Table 4-2-2A For wire diameters for different capacity of UPS system, please check the table 4-2-2B below Wire diameter of ground wire 10KVA 8mm 2 15KVA 8mm 2 22.5KVA 8mm 2 30KVA 14mm 2 45KVA 22mm 2 60KVA 22mm 2 80KVA 38mm 2 100KVA 38mm 2 120KVA 38mm 2 Table 4-2-2B

  • OPTI-UPS DS-C33 Series, 2-4-3 System is powered by battery (fig.2-4-3) Load Battery Pack + - Utility S3 Input protection Input switch Manual bypass switch S6 S.T.S. Rectifier S4 Battery switch Inverter Transformer S5 Output switch S1 Battery auxility switch AC choke DC choke Fig. 2-4-3 In the absence of the utility input, the rectifier stops and DC power is supplied by the batteries to the inverter module. The inverter converts the DC into AC. The static switch connects the inverter output to the load. At this time, the inverter supplies the load. When power is supplied by the batteries, the back up time depends on number of batteries and

  • OPTI-UPS DS-C33 Series, Table of contents 1.0 Preface ---------------------------------------------------------------------------------------- 1-1 1-1 Introduction ---------------------------------------------------------------------------- 1-1 1-2 Safety Note and Precaution ---------------------------------------------------------- 1-2 2.0 System structure ----------------------------------------------------------------------------- 2-1 2-1 System Diagram of DS-C33 --------------------------------------------------------- 2-1 2-2 System assembly and parts layout--------------------------------------------------- 2-2 2-3 Introduction on function of main module -------------

  • OPTI-UPS DS-C33 Series, 5-5 Introduction to LCD front panel and illustration of each function Introduction to function keys on the front panel → button: Moves the page cursor to the right ← button: Moves the page cursor to the left OFF button: “OFF” function key ON button: “ON” function key ↑button: Moves up the page cursor ↓button: Moves down the page cursor ENTER button: Execute/confirm setting ESC button: Return to previous page Use →,←,↑,↓ function key to select item on LCD menu and then press ENTER to enter the category you need. Use → and ← key

  • 4-2-3 Input/Output connection and precaution From table 4-2-1 and table 4-2-2, we could determine the installation wire diameter and breaker capacity, as shown below. Rating Mains voltage Input circuit breaker Input wire diameter (mm 2 ) Output circuit breaker Output wire diameter (mm 2 ) 110/190V 3P/60A 14 3P/50A 14 120/208V 3P/50A 14 3P/40A 14 10KVA 220/3

  • OPTI-UPS DS-C33 Series, 1 Preface 1-1 Introduction DS-C33 series UPS is one of the industry’s most reliable and stable power protection equipment. It is fully controlled by DSP (Digital Signal Processor) to ensure high performance and worry free operation in protecting your valuable equipment from power disturbances. This makes the DS-C33 series UPS fully compatible for use in computer, precision instrument, banking, manufacturing, and other mission critical applications. 1-2 Safety Note and Precaution Please note and refer to warning marks which you will find in the unit. Don’t touch

  • OPTI-UPS DS-C33 Series, 2-4-5 EPO switch (fig. 2-4-5) Load Battery Pack + - Utility S3 Input protection Input switch Manual bypass switch S6 S.T.S. Rectifier S4 Battery switch Inverter Transformer S5 Output switch S1 Battery auxility switch AC choke DC choke Fig 2-4-5 Be sure the to check if the EPO is switch otherwise it will not be possible to start up the UPS and no voltage will be supplied to the output load.

  • OPTI-UPS DS-C33 Series, 2-4 System operation mode 2-4-1 System is normal (Fig. 2-4-1) Load Battery Pack + - Utility S3 Input protection Input switch Manual bypass switch S6 S.T.S. Rectifier S4 Battery switch Inverter Transformer S5 Output switch S1 Battery auxiliary switch AC choke DC choke Fig. 2-4-1 Utility AC input supplies the rectifier /battery charger where the AC is converted into DC. Battery is recharged while the DC is fed to the inverter module. The static switch module connects the inverter output to the load while the bypass electricity is blocked. At this time power is supplied by inve

  • OPTI-UPS DS-C33 Series, 7 Specifications for DS-C33 Series UPS Model DS 10KC33 DS 15KC33 DS 22.5KC33 DS 30KC33 DS 45KC33 DS 60KC33 DS 80KC33 DS 100KC33 DS 120KC33 Capacity 10KVA 15KVA 22.5KVA 30KVA 45KVA 60KVA 80KVA 100KVA 120KVA Rating Power 8KW 12KW 18KW 24KW 36KW 48KW 64KW 80KW 96KW Power factor 0.8 Phase 3 Phase 3 wire / 3 Phase 4 wire and ground Voltage 380V/220V or 208V/120V ±20 % Frequency Auto-sensing, 50Hz/60Hz ±5 Hz Regulation style 3 phase 6 pulses or 12 pulses (option) DC voltage DC410V AC input Efficiency of rectifier >97% Efficiency of Inverter >90% Tot

  • OPTI-UPS DS-C33 Series, Status indication on LCD/LED panel is divided into 4 modes: (1) System Normal mode: In this mode, only INPUT, RECTIFIER, CHARGE, INVERTER, OUTPUT LEDs are illuminated and others LEDs are off. (2) System Bypass mode: INPUT, BYPASS and OUTPUT LEDs are illuminated and others are off. (3) Back-up mode: DISCHARGE, INVERTER and OUTPUT LEDs are illuminated and others are off. (4) Manual Bypass mode: When Switch S6 is switched to “ON” position, Only MANUAL BYPASS LED is on, others are off. It means that the system has transferred to Manual Bypass mode correctly. After S1, S2, S3 and S4 are switched “OFF”, use a discharging tool to release the remaining voltage on

  • OPTI-UPS DS-C33 Series, Voltage of DC chain voltage is too high (1)Ol-3302DCvoltage feedbacks point open circuit Recover feedbacks circuit (2)Ol-3302 feedbacks circuit error Replace ol-3302 (3)Ol-3300program parameter is too high Correct program parameter (4)SCR component short circuit Replace SCR component (5)Error on ol-3302 control Replace ol-3302 Voltage of DC chain voltage is too low (1)Ol-3302DCvoltage feedbacks point open circuit Recover feedbacks circuit (2)Ol-3302 feedbacks circuit error Relaceol-3302 (3)Parameter of ol-3300 program is too low Correct program parameter (4)Battery power is insufficient and uti

  • OPTI-UPS DS-C33 Series, 2-2 System assembly and parts layout Drawings 2-2A and 2-2B are the assembly diagrams of DS-C33 series 100K, 120K Fig. 2-2A Fan INV/Driver Board DSP Control Board Communication Port S2/S1 Switch S3 Switch S6/S5 Switch Input/Output Terminal INV Module Input AC Choke AC Power Sensor Board AS-400 Interface Card System Power Board S4 Switc h System Transformer S4 Battery Fuse

  • OPTI-UPS DS-C33 Series, (5) 1.Initial start up procedure: Make sure all the loads connected to the UPS are switched off. Turn on Switch S1, S2 and turn off S3 in sequence. Then turn off S4 fuse switch in the UPS. Press the “ON” button on the LCD panel and a screen for confirming setting appears. Press “ ENTER” button. A message “Setting complete” on the screen appears in a few seconds to indicate setting is successful. At that time the system will detect the battery for 30 seconds and then the UPS will transfer from Bypass mode to Inverter mode. Measure the output voltage and frequency on ter

  • OPTI-UPS DS-C33 Series, 5-3-2 Procedure for replacing battery (1) Turning off the INVERTER Push “OFF” button on the front panel and then push “ENTER” button to shut down UPS. At that time the UPS enters into maintenance bypass mode. (2) Switching into maintenance bypass mode Turn switch “S6” to “ON” position and put in place its protective cover, and then turn off switch of S5, S4, S3, S2 in sequence (only for some model), switch “S1” (“OFF” position). (3) Replacing the battery Wait for one minute and then remove iron sheet in front of the switch and battery apron. Remove battery connection wiring and replace with a new battery. Connect the wiring ag

  • OPTI-UPS DS-C33 Series, Model DS 10KC33 DS 15KC33 DS 22.5KC33 DS 30KC33 DS 45KC33 DS 60KC33 DS 80KC33 DS 100KC33 DS 120KC33 W 530mm 530mm 530mm 530mm 750mm 750mm 750mm 1100mm 1100mm D 875mm 875mm 960mm 960mm 800mm 800mm 800mm 800mm 800mm H 1010mm 1010mm 1180mm 1180mm 1700mm 1700mm 1700mm 1800mm 1800mm 120V/208V 427Kg 463Kg 457Kg 543Kg 743Kg 851Kg W 530mm 530mm 530mm 530mm 750mm 750mm 750mm 1100mm 1100mm D 875mm 875mm 960mm 960mm 800mm 800mm 800mm 800mm 800mm H 1010mm 1010mm 1180mm 1180mm 1700mm 1700mm 1700mm 1800mm 1800mm Physical size 220V/380V 333Kg 343Kg 345Kg 412Kg 544Kg 631Kg 752Kg 1410Kg

  • OPTI-UPS DS-C33 Series, USER SET 1 Alter security NO. 2 Battery test 3 Communication set 4 F. V. C/C set 5 Other set ALTER SECURITY NO. Key in old code **** Key in new code **** BATTERY TEST ▓ 30 Seconds □ 1 Month □ 3 Month □ Test OFF F. V. C/C SET 1 Frequency set 2 System input V 3 System output V 4 Output voltage 5 Charge current 6 Charger mode OTHER SET 1 Buzzer 2 Backup time 3 Language 4 Model type (C-4-1) (C-4-5) (C-4-2) (C-3) (C -4-4)

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Radio Shack 43-3808 Owner's manual radio-shack/43-3808-E3V.pdf 12 Aug 2022 20 0.09 Mb
2 Samsung SPH700AE - DLP Home Theater Projector Owner's instructions manual samsung/sph700ae-dlp-home-theater-projector-N5G.pdf 30 Aug 2023 42 5.66 Mb
3 Jeep Grand Cherokee SRT 2014 Owner's manual jeep/grand-cherokee-srt-2014-789.pdf 08 Oct 2022 118
4 WMF PROGRMAT GV Operating instructions manual wmf/progrmat-gv-7J4.pdf 05 Oct 2023 32
5 AOR AR-Mini Operating manual aor/ar-mini-7X1.pdf 18 May 2023 80 1.23 Mb
6 Savin 2555 Copy reference manual savin/2555-YGR.pdf 20 Dec 2022 39 0.8 Mb

Similar Resources:

  • Eaton

    91PS

    (138 pages)
    SAFETY AND INSTALLATIONQUICK GUIDEEaton 91PS/93PS UPS8-10 kW 400VDOWNLOAD FULL USER’S AND INSTALLATION GUIDE AT WWW.EATON.EU/93PS%100% 0 % 20 % 40% 60% 80 %95 %950 mm 750 mm 335 mm 130 ºC 10 ºC 20 ºC 30 ºC 40 ºC 50 ºC -10 ºC P-164000692 1 3 4 2 5 6 7 8 10 12 9 11 12 5 3 467 1 3 5 7 9 11 13 2 4 6 8 10 12 14 16 15ATB201234NO NC1 …
  • Eaton

    9PX

    (52 pages)
    p/n: P-164001006Revision 01Eaton 9PX Lithium-Ion Advanced Users Guide9PX1500RT-L / 9PX2200RT-L / 9PX3000RT-L / 9PX1500GRT-L /9PX2200GRT-L / 9PX3000GRT-L / 9PXEBM48RT-L /9PXEBM72RT-LEaton 9PX Lithium-Ion …
  • Sferalabs

    Strato Pi SPMU30X

    (36 pages)
    !Strato Pi UPS User GuideJuly 2021Revision 027SPBU30X Strato Pi UPS boardSPMU30X Strato Pi UPS server with Raspberry Pi 3 Model BSPMU30XP Strato Pi UPS server with Raspberry Pi 3 Model B+SPMU30X41 Strato Pi UPS server with Raspberry Pi 4 Model B 1GBSPMU30X42 Strato Pi UPS server with Raspberry Pi 4 Model B 2GBSPMU30X44 Strato Pi UPS server with Raspberry Pi …
  • Dell

    1000W

    (184 pages)
    Dellt Line-Interactive Rack UPS1000W, 1920/1500W, and 2700/2300WGetting Started WithYour SystemDémarrage avec votre systèmeErste Schritte Mit Ihrem SystemНачало работы c вашей системойInicio de su sistema系统使用 入门指南系統使用 入門指南사용자의 시스템 시작하기はじめに システムについてK792N, …
  • PROLiNK

    MASTER II Series

    (20 pages)
    BEFORE GETTING STARTED This document is designed to aid you to get started with the device. If you experience problems following these guides or need further information pertaining to the device, please visit our website at www.prolink2u.com. All specifications are subject to the manufacturer’s configuration at the time of shipping and may change without …
  • N1C

    L60

    (7 pages)
    N1 Critical Technologies, Inc.L60/L60i Lithium Ion UPS© 2018 - N1 Critical Technologies, Inc., Rev 2/1/19n1critical.com | lithium-ion-ups.comUser and Installation ManualEnglish350VA Model …

Comments, Questions and Opinions: