  • Arada Hamlet, Wet Stove User Guide 2 More than 20 years experience has been put into the development of our stoves to ensure ultimate performance and years of trouble free use and enjoyment. and engineered which is why we are so confident in the reliability of our products. Should you have any questions about our stoves that are not covered by this manual, please contact the Arada retailer in your area, or call our technical support department on 08448 567181. All Arada stoves are tested to European Standard EN 13240. WARNINGS Pure Petrole

  • Arada Hamlet, Wet Stove User Guide 3 OPERATING YOUR STOVE Our boiler stoves are designed to be operated with the fire door(s) closed at all times, apart from refuelling (when alight) or cleaning (when cold). Never leave the appliance unattended for an extended length of time with the door(s) open. Visit our Youtube channel for our ‘how-to’ series of videos: http://www.youtube.com/aradastoves FUEL TYPES WOOD Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored t

  • Arada Hamlet,  A Carbon Monoxide detector is correctly installed in the same room as the appliance. WARNING: An over drawing chimney can cause over firing, resulting in damage to the appliance. Ensure that you have read and understood these instructions before lighting the fire. Do not light the fire if is is suspected that any part of the system could be frozen. Always wear suitable protective fire gloves when refuelling your stove, such as the Arada glove supplied with your stove. We recommend that you light a small fire for the first

  • Arada Hamlet, Sliding it to the LEFT will shut off the air inlet slots . EASY BOOST BURNING WOOD  this.  The use of two or three fire lighters may assist to light the kindling.  Set the airwash and easy boost controls to the fully open position.  Light the fire.  After the kindling has caught light, you should leave the fire door ajar by about 20mm. This will aid flue draw.  The flue draw should be established after five minutes, and the kindling reduced to form an ember bed.  Carefully load the stove with well seasoned wood and close the fire door.  After ten to fifteen minutes, regulate the airwash control, typically redu

  • Arada Hamlet, USER GUIDE fuel will fall between the grate bars into the ash pan below. This will ensure a good under draught is maintained. This is done by rotating back and fourth the riddling lever on the side of the stove. The operating tool supplied with the stove should be used for this purpose. WARNING: Properly installed, with a suitable flue or chimney, operated and maintained correctly, this appliance will not emit fumes into the dwelling. Occasional fumes when de-ashing and refuelling may occur. However, persistent fume emission is potentially dangerous and must be investigated by a HETAS registered installer. Stop using the appliance if you smell fume

  • Arada Hamlet, USER GUIDE 7 Wet Stove User Guide REDUCED BURNING When wood is burnt slowly in a closed appliance, it produces moisture and tar, which will create condensation and deposits in the chimney. This effect can be minimised by burning hard for a short period, fifteen to twenty minutes, twice a day. The easy boost air inlet can be used to achieve this faster burn rate. Remember to close the easy boost inlet afterwards as this overrides the stoves automatic thermostatic control. Please Note: To avoid chimney problems your appliance should not be burnt at a reduced burn rate without a period of fast burning

  • Arada Hamlet, MAINTENANCE 8 Wet Stove User Guide SUMMER STORAGE / NON USAGE Please ensure that your stove is left clean and moving components are well lubricated for the summer months (during periods of prolonged non-use). If possible store the FEDS plate outside of the stove. Check all moveable components at regular intervals, to ensure they are moving freely. Allow air movement through the stove, by opening the airwash and primary air inlet control(s) to about half way, open or leave the door ajar. This will allow a free flow of air through the appliance maintenan

  • Arada Hamlet, Wet Stove User Guide 9 GUARANTEE When you buy a Hamlet Solution Boiler stove, you are not only buying a first class appliance you are buying a commitment from us to look after you and your appliance for as long as you want. All Hamlet Solution Boilers will have a three year guarantee as standard. This guarantee applies to stoves fitted in the same country as its purchase. Stoves brought through the internet in the UK and then taken abroad will not be eligible for any guarantee. All guarantees apply to the body of the fire, i.e. the steel ca

  • Solution 9 HSB9 4.5 7.5 9 570 22 1/2 Solution 12 HSB12 6 9.5 12 603 23 3/4 Solution 16 HSB16 8 13 16 603 23 3/4 Technical Information Description Height mm inches Solution 9 Inset HSB9-INSET 4 7 9 590 23 1/4 Solution 12 Inset HSB12-INSET 5 9 12 590 23 1/4 Description Height mm inches Inset Model

  • Arada Hamlet, 468 18 1/2 417 16 1/2 431 17 144 5 3/4 230 210 101 4 74.3% 535 21 417 16 1/2 452 17 3/4 149 5 3/4 245 225 127 5 73.4% 590 23 1/4 417 16 1/2 504 19 3/4 149 5 3/4 250 240 127 5 71.8% Depth mm inches Width mm inches Depth from back to centre of top flue mm inches Height to centre of rear flue mm inches Flue Diameter mm inches Nett Efficiency 581 22 3/4 532 21 353 14 179 7 71.8% 581 22 3/4 532 21 353 14 179 7 71.5% Depth mm inches Width mm inches Depth

  • Arada Hamlet, BK570 Rev02 Final Factory Check list Quality / Finish Flue Outlet Hot Plate Fuel Retainer Firebox Liners Throat Plate Door Catch / Door Handle Operating Tool Stove Glove Grate / Fuel Bed Installation Guide Assembled By……………………….... Checked by………………………………. Model: The Fireworks Weycroft Avenue Axminster Devon EX13 5HU www.aradastoves.com www.aradastovesandspares.com We recommend recording where and when you purchased your stove for future reference:

More Instructions:

DOWNLOAD

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Nissan Xterra Manual  nissan/xterra-2S8.pdf 22 Feb 2024 19
2 Neopost AS 226p Operation & user’s manual neopost/as-226p-XX2.pdf 02 Nov 2023 33
3 Himoto Bowie monster truck E10MT Assembly manual himoto-bowie/monster-truck-e10mt-MYR.pdf 26 Sep 2022 24
4 Fishman RARE EARTH BLEND Installation manual fishman/rare-earth-blend-LI4.pdf 05 Jun 2023 2 0.13 Mb
5 NETGEAR MA111 Specifications netgear/ma111-6V1.pdf 09 Dec 2022 2
6 Bircher Reglomat Herkules 2E Original instructions manual bircher-reglomat/herkules-2e-9X2.pdf 03 Aug 2023 8

Similar Resources:

  • Trianco

    EuroTrader 50/90

    (28 pages)
    To be retained by householderUSER, INSTALLATIONCOMMISSIONING & SERVICINGINSTRUCTIONSEuroTrader 50/90EuroTrader 100/125OIL FIRED CENTRAL HEATING BOILERSFOR BALANCED OR CONVENTIONAL FLUETRIANCOBED 92/42 EECEMC 89/336 EEC …
  • Slant/Fin

    VICTORY VSPH SERIES

    (20 pages)
    HOT WATER/GASMODULAR BOILERSAPPLICATION GUIDEPrinted in the U.S.A. 1008 Publication No. CJ-10-HWGwww.slantfin.comGuidelines for the design, purchase and installation of Slant/Fin Jaguar Caravan gas-fired, hot water modular boiler systems.®CONTENTSIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Recommended Piping . . . . . . . …
  • Lennox

    OWB86-3

    (28 pages)
    RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCEThese instructions must be axed on or adjacent to the boiler. PN 240013016, Rev. A [07/31/2020]INSTALLATION INSTRUCTIONSPRODUCT LITERATURELennox Industries Inc.Dallas, TexasTested For 50 psi.ASMEWorking PressureWARNINGImproper installation, adjustment, alteration, service, or maintenance could result in dea …
  • Viessmann

    B2HB009

    (64 pages)
    Please file in Service Binderfor use by heating contractor5461 884 - 14 01/2019Installation InstructionsVitodens 200-W, B2HBModels 19, 26, 35, 68, 94, 125Wall-mounted, gas-fired condensing boilerFor operation with natural gas and liquid propane gasHeating input: 12 to 125 MBH 3.5 to 37 kWVITODENSr 200-WRead and save these instructionsfor futur …
  • A.O. Smith

    Burkay Genesis GB 1000

    (12 pages)
    1GAS-FIRED COMMERCIALREPLACEMENT PARTS LISTCOPPER BOILERS FOR HYDRONICHEATING & HOT WATER SUPPLYMODELS GB/GW: 1000, 1300,1500, 1850, 2100, 2500SERIES: 400 - 405A.O. SMITH WATER PRODUCTS COMPANY500 TENNESSEE WALTZ PARKWAY, ASHLAND CITY, TN 37015Phone: 1-800-433-2545 • Fax: 1-800-433-2515website: www.hotwater.com/parts • email: [email protected]
  • Zip

    Econoboil HS403

    (12 pages)
    Installation and Operating InstructionsZip EconoboilBudget priced instant boiling water for canteens and kitchens.03592 Zip Econoboil 2.5 litre White HS40305592 Zip Econoboil 5.0 litre White HS40507592 Zip Econoboil 7.5 litre White HS407 …

Comments, Questions and Opinions: