Adarad DUNATECH 2012, NEW DUNATECH 201 2 Cast Iron Boiler for Solid Fuel Firing Installation and User Manual Cast Iron Boiler for Solid Fuel Firing Installation and User Manual 1783 Cast Iron Boiler for Solid Fuel Firing Installation and User Manual CALOR SRL Str. Progresului nr. 30-40, sector 5, Bucuresti tel: 021.411.44.44, fax: 021.411.36.14 www.calorserv.ro - www.calor.ro
Adarad DUNATECH 2012, Dunatech is a cast iron sectional boiler for solid fuel firing which is constructed with new patent secondary air system principle providing a clean burn and low emissions . It is designed for hot water heating systems, should not be used for direct sanitary water supply. Thanks to its cast iron body design with flexible casting technology, your boiler is quite resistant to corrosion that could be caued by low return water and flue gas temperatures respectively, and high water content of the fuel being charged. Dunatech boiler will give higher heating surface area and water efficiencies among similar products in the market, as well as lower pollutants and flue gas
Adarad DUNATECH 2012, TECHNICAL DATA Model DUNATECH3 DUNATECH4 DUNATECH5 DUNATECH6 DUNATECH7 DUNATECH8 Numberofsections 345678 Fuels Outputrange kW 14‐17 20‐27 27‐34 33‐41 38‐46 42‐51 Netweight kg 135 165 195 225 256 286 Watercontent lt 22 28 34 40 46 52 Combustionchembervolume dm3 30 42 55 68 81 94 Fuelloadingvolume dm3 20 28 36 45 53 62 Maxfuelloadingheight cm Temperaturecontrolrange °C Maximumoperatingtemperature °C Minimumreturntemperature °C Saf
INSTALLATION Handling of the product Dunatech is a heavy product, and care should be taken when carrying the boiler to the room where it is going to be installed. The total weight of each boiler is indicated in Technical data section. Carrying equipments of product must be of enough capacity to support that weight. Room selection Dunatech boiler must be installed in an
Adarad DUNATECH 2012, Hydraulic circuit Open vented hydraulic circuit Dunatech boilers are preferred to be installed in a hydraulic circuit with an open type expansion tank in accordance with the following schemes. The circulation pump in the circuit should be installed on the return line to boiler in order to prevent the system from excessive thermal stresses and overheating during electricty cuts off: 6 Open type expansion tank must be installed at the heighest level of whole hydraulic system. No globe valves must be installed on delivery and return safety lines between boiler and expansion tank. Safety lines should be
Adarad DUNATECH 2012, 7 Design parameters for open expansion tank Expansion tank protects the hydraulic curcuit from excessive temperatures by allowing free volume for expanding water and keeping the water pressure from exceeding the static pressure. Expansion tank may be built in rectangular prism or cylindirical shape, may be installed in horizontal or vertical position in the system. Safety lines between boiler and expansion tank should be installed by an increasing slope up to tank. Following scheme shows the maximum vertical distanc
Pressurised hydraulic circuit Dunatech boiler can be installed in a pressurised heating system if following scheme is referred with addition of the safety heat exchanger kit which is supplied as a separate accessory. maximum p ressure: 3 bar 8 p essu e 3 ba Safety heat exchanger includes the following items: 1. Safety heat exchanger (copper serpantine integrated with outlet stu
Adarad DUNATECH 2012, Chimney connection Dunatech boiler must be connected to an individual chimney that will provide at least the minimum draught requested. The flue canal between the boiler and the chimney should be insulated using a glass wool material. The flue canal to chimney and chimney must be made of steel or an equivalent material that can be used at temperatures around 400 C A ll connections on the flue system must be sealed in order to perform a good combustion and efficiency. The flue canal must be connected to the chimney using the shortest way and in accordance with the dimensions given
Adarad DUNATECH 2012, A SSEMBLY INSTRUCTIONS Numbers between paranthesis refer to bubble numbers in exploded drawing of the boiler that can be found at the end of this manual Dunatech boiler should be installed on a concrete plinth made of a fireproof material. We recommend you to place two pieces of steel sheetmetals underneath the front and rear elements of the boiler preferably with the dimensions H: 3 mm x L: 500 mm x D: 200 mm. Follow the instructions to finish the assembly of boiler accessories supplied together with the boiler 10 37 48 47 47 1. Fit the thermo-regulator into the port on the front section Use linen fibres against water leakage. Position the thermo-regulator with its
Adarad DUNATECH 2012, 6. Likewise, fit the right hand side panel (39). When you work at the front side of the boiler, loose three M8 nuts (G) that are used to secure front door hinges (28, 29) a little, drive the front bend of the panel through the free space behind A8.4 flat washer (F). After driving the panel to right position secure it by screwing the same M8 nuts. You can set the hinges by loosing or screwing to provide that the doors are closing properly. 7. Place top panel (40). Before securing top panel, first fit the thermometer (43), drive the capillary of the thermometer through the hole on the top panel, and attach its sensing bulb inside the pocket on the front element
Adarad DUNATECH 2012, 13. by fixing the rear casing follow the instructions: ― Fit the rear panels as it is seen in the pictures. ―Finally fit the damper onto the rod. please see the following pictures. 13 51 A B 13 42 L 51 A B 13 42 L 51 A B
Adarad DUNATECH 2012, Safety heat exchanger (optional) The safety heat exchanger is used to save the boiler in case of overheating. In case of electrical cutout, pump defect etc. the boiler water temperature can be overheated. If the boiler water temperature exceeds 95 ºC, thermostat of the safety valve lets cold sanitary water flows through the serpantine of the safety heat exchanger. Serpantine with cold water circulating inside cools down the boiler water temperature. When the boiler temperature decreases below the safe degree, safety valve shuts the col
1. Remove the existing outlet stub pipe with flange of the boiler 2. Install the safety heat exchanger to the delivery port on the rear section by four pieces M10X25 bolts. Use gasket supplied with safety heat exchanger to provide sealing. 3. Attach the hot water delivery line to the port on top of the flanged pipe of the safety heat exchanger. 15 4. Fit t
Adarad DUNATECH 2012, OPERATING INSTRUCTIONS Setting the thermo-regulator (thermostatic controller for combustion air) Mechanic type thermo-regulator is mounted on top of front section in vertical position. In vertical operation of thermo- regulator, red coloured numbers show the requested heating temperatures. After assembly of thermo-regulator body, place the lifting rod for regulator. Load the boiler and fire. Wait until the boiler temperature reaches 60 C. Set the thermo-regulator to 60 C. Attach one end of thermo-regulator chain to primary air damper. Attach the other end the chain to lifting rod of thermo-regulator, and stretch the chain, leaving 2 mm space between primary dam
Adarad DUNATECH 2012, Firing with hard coal and coke *If you fire hard coal or coke, we recommend you to keep secondary air damper fully open. If your chimney is built enough to ensure an adeqaute draught, you can keep secondary air damper 1/2 closed. *Flue damper on the smokehood should be kept fully open or 2/3 open. *When you have low fire or smaller fuel bed you can decrease the draught by closing the dampers further Stand-by *You can slow-down the combustion by a. Decreasing the set temperature on the thermo-regulator b. Closing the secodary air damper fully c. Closing the flue damper fully Your boiler does not switch the pump on and off automatically. Th
Adarad DUNATECH 2012, HEALTH AND SAFETY INFORMATION Control of substances hazardous to user health For the type of material and where used in Dunatech boiler refer to the following chart 1. PAINTS: General purpose black undercoat NOT APPLICABLE High temperature black coating Sections Boiler body bottom plate Powder coating A ll jackets 2. INSULATION AND SEALS Rock-wool insulation board NOT APPLICABLE Glass-wool insulation board Sections (aluminum backed) Smokehood Fibre-glass rope and tape Front doo r Between bottom plate and sections Ceramic-fibre board Front doo r CFC free polyur
Devices under pressure 1. Avoid contact with the parts of heating system under pressure during operation of boiler. These dangerous parts are such that: Boiler sections Boiler inlet and outlet lines Safety lines Pressure relief devices installed on heating system 2. Never attempt to drain water from heating system when the boiler is being operated 3. Never feed the boiler directly with col
Adarad DUNATECH 2012, MAINTENANCE AND CLEANING Regular maintenance by qualified staff, strictly in accordance with the manufacturers instructions is essential for the efficient operation of system. Periodic inspections * Check the water level or pressure either in open vented or pressurised systems. The hydrometer must be marked after first filling of the boiler. So water level can be checked regularly. If the water level or pressure is under the level of static pressure or the system set-up, a water make-up is needed. The make-up water should be softened according the local regulations before fee
Adarad DUNATECH 2012, SPARE PART LIST Nr. 1 3 4 7 8 9 2007610411 2007610498 2007610453 2007610454 2007610455 2007610414 DEEP PLATE (6 SECTIONS) 2007610415 DEEP PLATE (7 SECTIONS) 2007610416 DEEP PLATE (8 SECTIONS) 6 2007610412 DEEP PLATE (4 SECTIONS) 2007610413 DEEP PLATE (5 SECTIONS) 2007603339 2007603341 TIE ROD (3 SECTIONS) 2007610452 TIE ROD (5 SECTIONS) 2007160315 2007610491 2007610492 2007610493 2007610451 DEEP PLATE (3 SECTIONS) 2 5 CODE 2007602285 NIPPLE DUNATECH REAR SECTION DUNATECH INTERMEDIATE SECTION (WITHOUT BY-PASSES - WITH TIE PIECE) DUNATECH FRONT SECTION TIE ROD (4 SECTIONS)
Adarad DUNATECH 2012, SPARE PART LIST Nr. 41 42 43 45 2007610431 DUNATECH SIDE CASING (RIGHT HAND) (Ral 9006 EW 0794) 6 sections 2007610428 2007610429 DUNATECH SIDE CASING (RIGHT HAND) (Ral 9006 EW 0794) 3 sections DUNATECH SIDE CASING (RIGHT HAND) (Ral 9006 EW 0794) 4 sections 39 46 2007610445 ASH TRAY - FOR 4 SECTIONS 2007610446 ASH TRAY - FOR 5 SECTIONS 2007610447 A SH TRAY - FOR 6 SECTIONS 2007610442 DUNATECH REAR LOWER CASING 2007065460 THERMOMETER (0-120) 1,5MT 2007610444 ASH TRAY - FOR 3 SECTIONS 2007610438 DUNATECH TOP CASING (Ral 9006 EW 0794) 7 sections 2007610439 DUNATECH TOP CASING (Ral 9006 EW 0794)
Buderus 600 - 11S Boiler Operation & user’s manual
600 - 11S |
Dunkirk XEB-2 Boiler Installation instructions manual
XEB-2 |
Argo EMIX Boiler Operating instructions manual
EMIX |
Hamworthy F175V Boiler Installation, commissioning and operating instructions
F175V |
Alde Comfort 2920 Boiler Installation instructions manual
Comfort 2920 |
Biasi Activ A 18S Boiler User manual and installation instructions
Activ A 18S |
IBC Technologies SL 80-399 Boiler Installation and operating instructions manual
SL 80-399 |
Pinnacle PI-399 Boiler Installation and operation manual
PI-399 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Quinny | zapp xtra | Instructions for use & warranty | quinny/zapp-xtra-65L.pdf | 15 Jan 2023 | 28 | 2.06 Mb |
2 | Sony | SVE14A1M6EB | Troubleshooting manual | sony/sve14a1m6eb-1B7.pdf | 08 Oct 2022 | 2 | 0.4 Mb |
3 | Cradlepoint | CRADLEPOINT IBR650 | Operation & user’s manual | cradlepoint/cradlepoint-ibr650-Q3W.pdf | 29 May 2023 | 131 | 4.6 Mb |
4 | Blackberry | PEARL 8120 - S-MIME SUPPORT PACKAGE FOR DEVICES | Safety and product information | blackberry/pearl-8120-s-mime-support-package-for-devices-IPK.pdf | 23 Sep 2022 | 33 | 0.61 Mb |
5 | Panasonic | KX-TU301FX | Operating instructions manual | panasonic/kx-tu301fx-9P7.pdf | 31 Dec 2022 | 36 | 2.13 Mb |
6 | Panasonic | KV-SV50U | Operation manual | panasonic/kv-sv50u-RC4.pdf | 11 Sep 2022 | 20 | 0.73 Mb |
Viessmann
Service andMaintenance Instructionsfor use by engineers and heating contractors5603 880 - 01 12/2014Read and save these instructionsfor future reference.KRT 150 to KRT 540 SeriesWood-fired BoilerMax. output: 150 to 540 kW / 512 to 1843 MBHMin. output: 45 to 140 kW / 154 to 478 MBHPyrotrProduct may not be exactly as shownIf the information in this ma …
KRT 150 series(28 pages) |
Viessmann
VITOCONTROL-S, WB2BOperating Instructionsand User’s Information ManualVitodens 200-W, WB2B SeriesMulti-boiler system with control units for operation with a constanttemperature and weather-compensated cascade control unitFor operation with natural gas and liquid propane gasCertified as a component partof Viessmann boilers onlyVitotronic 100, HC1Vitocontrol …
Vitotronic 100 HC1(48 pages) |
Slant/Fin
CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGEDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,3Installation Requirements:Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Boiler Foundation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Chimney Requirements …
VICTORY VSPH SERIES(20 pages) |
Viessmann
VIESMANNInstallation instructionsfor contractorsVitosol 300-TType SP3AVacuum tube collector based on the heat pipe principleVITOSOL 300-T5366 351 GB 8/2008 Dispose after installation.
…
Vitosol 300-T(36 pages) |
ENERGY KINETICS
Step 2 Open Front Cover 1. Loosen, but DO NOT REMOVE (2) lower nylock nuts on hinge bolts below burner. 2. Remove (3) upper nuts and support cover while opening. 3. Inspect burner head/end cone condition. ANNUAL TUNE UP & INSPECTION Annual Tune Up and Inspection Ascent™ Combi & Ascent™ Plus Combi Gas …
Ascent Combi(3 pages) |
Ataq
O p e r a t i n g i n s t r u c t i o n s8G.52.4001/12.10 Changes reservedBoiler G.CNoQ25S 41-310-08Q38S 41-310-09Q51S 41-310-10Q60S 41-310-11Q25C 47-310-10Q38C 47-310-11Q51C 47-310-12CE PIN 0063BQ3021
…
Q 25S(16 pages) |
LSIS Controller XGT SeriesXGT Series (Controller ePDF User Manual, #UR17U8) XGT Series, 61 |
CAB Printer A8PDF User Manual (@76R5LG), CAB A8 Printer (Saturday 11-11-2023) A8, 93 |
ViewSonic Monitor Q20wb#7153V6 Q20wb: ViewSonic Monitor Owner Documentation Q20wb, 22 |
CircuPool Swimming Pool Filter RJ-PLUS SeriesRJ-PLUS Series Owner's manual - R99IF4 RJ-PLUS Series, 32 |
Panasonic TV TX-29AD3PService manual for Panasonic TX-29AD3P TV TX-29AD3P, 39 |
Electrolux Ice Maker CIM24AElectrolux CIM24A Ice Maker Specification sheet CIM24A, 2 |
CAME Gate Opener BKV15AGECAME Gate Opener Installation manual (File: came-bkv15age-installation-manual-40, Wed 10.2023) BKV15AGE, 40 |
DentalEZ Dental equipment J-Chair J-3Dental equipment #YHM2P3 J-Chair J-3, 45 |
Reliable Steam Cleaner 6000 SERIESInstruction manual for Reliable 6000 SERIES Steam Cleaner 6000 SERIES, 56 |
Vortex-RC Toy VT-AllRounderToy PDF Instructional manual VT-AllRounder, 35 |
Ivation Meat Grinder IVEMG180SIvation IVEMG180S Guide (Doc Type: Meat Grinder Operation & user’s manual) IVEMG180S, 5 |
Swann Fryer SD6020NSwann SD6020N Guide (Manual ), @UQ1R1K SD6020N, 5 |