Compu-aire CELHP Installation, Operation, Maintenance And Parts Manual

  • CELHP Air Conditioner
  • manOXXCjYykD2
  • Installation, Operation, Maintenance And Parts Manual
  • PDF / Adobe Acrobat Reader
  • 16

Compu-aire CELHP Manual Online:

3.7, 547 votes
Compu-aire CELHP User Manual
Compu-aire CELHP User Guide
Compu-aire CELHP Online Manual

Text of Compu-aire CELHP User Guide:

  • Compu-aire CELHP, INSTALLATION OPERATION MAINTENANCE AND PARTS MANUAL CELLU – KOOL SERIES MODEL TYPE SIZE CELHP HEAT PUMP 1 ½ TO 5 TON CELAC AIR CONDITIONER 1 ½ TO 5 TON COMPU – AIRE INC. 8167 BYRON RD. WHITTIER, CA 90606 PH : (562) 945 – 8971 FAX : (562) 696 - 0724

  • Compu-aire CELHP, - - GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the air conditioner or heat pump. You can usually find these at your local 1 ibrary or purchase them directly from the publisher. Be sure to consult current edition of each standard. National Electrical Code -ANSI/NFPA 70 Standard For The Installation Of Air Conditioning and Ventilating Systems Standard For Warm Air Heating and Air Conditioning Systems Load Calculation For Residential Winter and Summer Air Conditioning Duct Desi gn For Residential Winter and Summer Air Conditioning and Equipment Selection -ANSI/NFPA 90A -ANSI/N

  • Compu-aire CELHP, CELLU- KOOL AIR CONDITIONER ,LID H PUMP AIR OUT ELECTRIC HEATER (OPTIONAL) - EVAPORATOR COIL / EVAPORATOR BLOWER I. HIGH EFFICIENCY MOTOR H' -' 7 HIGH COMPRESSOR - 'AGE CONTROL PANEL CONDENSER COIL - MODEL DESIGNATIOX 3 3 4 HASE I= SINGLE PHASE 3= THREE PHASE YSTEM CAPACITY 2= 2TON, 3= 3TON, 4=4 TON YSTEM TYPE AC= AIR CONDITIONER HP= HEAT PUMP ERTICAL WALL HUNG UNITS

  • Compu-aire CELHP, SUPPLY Am r INLeT ACCESS PmL ---. FILTER AND BLOWER MOTOR FREE CONDENSER AIR INLET Ur C0N.DESATE DRAIN - 1/2'M0UNTING HOLE . FREE COOLrNG AIR INLET CONDENSER AIR INLET REAR VIEW ACCESS CONDENSING FRONT VIEW MoToR dr FAN 6187 BTmN Ram vlmlmR a-BOW6 r

  • Compu-aire CELHP, GENERAL The equipment covered in this manual is to be installed by tralned, experienced service and installation technicians. The refrigerant system is conpletely assembled and charged. All internal wiring is complete. The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts. These instructions explain the reconmended method to install the air cooled self - contained unlt and the electrical wiring connections to the unit. These instructions

  • Compu-aire CELHP, FILTERS a A 1 - inch throwaway filter is supplied with each unit. The filter slides into position naklng it easy to service. This filter can be serviced from the outside by renoving the service dm. A 1 - inch washable filter and 2-'inch pleated filter are ah0 available as optional accessories. The internal filter brackets are adjustable to accommodate the 2-inch filter by loosening 2 screws in each bracket assembly and sliding the brackets apart to the required width and retightening the 4 screws. OPTIONAL FRESH AIR INTAKE All units are built with a fresh air inlet slots punched i

  • Compu-aire CELHP, Locate and nark lag bolt locations and bottom mounting bracket location, if desired. See Figure 2, kunt bottom mounting bracket. if used. Book top rain flashing under back bend of top. Top rain flashing is shipped attached to the back of the unit on the right side. Position unit in opening and secure with 5/16 lag bolts: use 3/4 inch diameter flat washers on the lag bolts. Secure rain flashing to wall and caulk across entire length of top. See Figure 7. For additional munting rigidity, the return air and supply air frames or collars can be drilled and screwed or welded to the structur

  • mE: IT IS -ED THAT A BEAD OF SILICONE CAULKING BE PLACED BEHIND TEE SIDE WOWING FLANGES AND UNDER TE TO? FLASHING F-- FWI AIR SEK WE: I1 1s REUIICMB] nu1 A BW1 a SlllCDH WWG BE m mtlm ME SlE m1H6 ~s~~1ff ~AlIlIEff IKSIMLAIIM.

  • Compu-aire CELHP, FIGURE 2A ELECTRIC BEAT CLEWS SEE NOTE 1 Side section view of supply air duct for wall naunted unit showing 1/4" clearance to conbustible surfaces. WARNING A nininus of 114" clearance must be namtained between the supply air duct and conbustible naterlals. This is required for the first 3 feet of ducting. 1 I I It is important to insure that the lt4" mininun spacing is maintained at all pints. I / Failure to do this could result in overheating the mnbuntible material and nay result in a fire. I

  • Compu-aire CELHP, Refer to the unit rating plate for wire sizing information and maximum fuse or " HACR Type " circuit breaker size. Each outdoor unit is marked with a "Minimum Circuit Ampacityw. This means that the field wiring used must be sized to carry that amount of current. Depending on the installed KW of electric heat, there may be two field power circuits required. If this is the case, the unit serial plate will so indicate. All dels are suitable only for connection with copper wire. Each unit and/or wiring diagram wi 11 be marked " Use Copper Conductors On1 y " . These instructions MUST BE adhered to. Refer to the National Ele

  • SEQUENCE OF OPERATION COOCIW-Circuit R - Y makes at thermostat pulling In conpressor contactor, starting the compressor and outdoor mtor. The G (indoor mtor) clrcuit is automatically conpleted on any call for cooling operation or can be energized by manual fan sw~tch on subbase for constant ax circulation. HIU1IE--A 24'4 solenoid coil on

  • TROUBLESHOOTING SOLID STATE HEAT W COKFROC TRWBLESHOOTING PROCEDURE 1. Turn on AC power supply to indoor and outdoor units. 2. Turn thermostat blower switch to fan on--the indoor blower should start. (If it doesn't, troubleshoot indoor unit and correct problem). 3. Turn thermostat blower switch to auto position. Indoor blower should st

  • Compu-aire CELHP, FAN BLADE SETTING DIMENSIONS Shown in the drawing below are the correct fan blade setting dimensions for proper air delivery across the outdoor coil. Any service vork requiring renxral or adjustment in the fan andlor notor area will require that the dinensions below be checked and blade adjusted in or out on the motor shaft accordingly. REMOVAL OF THE FAN SHROUD 1. Diconned: all power to unit. 2. Reme the screws holding both grills--one on each side of

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Poulan Pro 530164435 Instruction manual poulan-pro/530164435-77R.pdf 22 Oct 2022 12
2 Cameo CLTWINSCAN20 Operation & user’s manual cameo/cltwinscan20-C7W.pdf 14 Feb 2024 40
3 NAD M56 Bedienungsanleitung nad/m56-714.pdf 16 Aug 2023 30
4 Intel DZ77BH-55K Specification intel/dz77bh-55k-T53.pdf 25 May 2023 100
5 Kenmore 110.C9772 Series Use & care manual kenmore/110-c9772-series-8X6.pdf 14 Sep 2023 56
6 Audiovox VODEXL10 Owner's manual audiovox/vodexl10-KJ6.pdf 26 Sep 2023 36

Similar Resources:

  • Emerson

    Liebert Challenger 3000

    (72 pages)
    Precision CoolingFor Business-Critical Continuity™Liebert® Challenger™ 3000/Liebert Challenger ITR™ with Liebert iCOM® ControlOperation & Maintenance Manual - 50 & 60Hz …
  • Fortress Technologies

    FWAC08M18

    (32 pages)
    Window Air ConditionerUser ManualModelFWAC08M18 FWAC10M18FWAC13M18 FWAC19M18使用或安裝本產品前,請仔細閱讀本說明書,及所有安全注意事項,並請妥善保存,以備日後參考查閱。Before operating or installing the appliance, please read this manual and all the safety instructions thoroughly and retain it for future ref …
  • GE

    AGX10AJ

    (2 pages)
    Note: When installing slide-out chassis units in through-the-wall applications, keep louvers free. Do not restrict air flow areas. Fixed chassis units are not suitable for through-the-wall applications.Wall Outlets: All wiring including installation of receptacle must be made in accordance with local electrical codes and regulations. Electrical outlet shoul …
  • Mitsubishi Electric

    Mr.Slim PKA Series

    (58 pages)
    SERVICE MANUAL CONTENTS 1. REFERENCE MANUAL................................... 2 2. SAFETY PRECAUTION................................... 3 3. PARTS NAMES AND FUNCTIONS................. 8 4. SPECIFICATIONS........................................... 9 5. NOISE CRITERION CURVES......................... 10 6. OUTLINES AND DIMENSIONS...................... …
  • Hitachi

    RAS-70YH5A

    (34 pages)
    – 1 –ENGLISHDEUTSCHFRANÇAISITALIANOESPAÑOLPORTUGUÊS∂ÏÏËÓÈοРУССКИЙSPLIT TYPE AIR CONDITIONERINDOOR UNIT/OUTDOOR UNITMODELRAS-70YH5A/RAC-70YH5INDOOR UNITRAC-70YH5RAS-70YH5AOUTDOOR UNIT(EN PG 1) RAS/RAC-70YH5A 4/24/08, 14:421Black …
  • Amana

    AP095R

    (35 pages)
    PORTABLE A_R CONDiTiONERPORTAT_FACOHD_C_O B DE A_RE PORTAT_LUser ManualModel # AP095RGuide de I_Utilisateu_ *Mod6b # AP095RManua_ de_ Usua_ioPa_a Modelo de # AP095RI,_fo_ _ operating thb_ oven_ please _ead the.> instructions corn@ _t_ly …

Comments, Questions and Opinions: