  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 34 6.9.3  Fault and Alarm Displays Fault and alarm displays any malfunctions the Alpha FXM has encountered. Also see "Troubleshooting". Table I — Faults Shor t_Circuit The load has a short. Vout_Hi The output voltage is above specifications. Batt_Hi The batteries cannot be charged. Batt_Lo The batteries are almost discharged. Vout_Lo The output voltage is below specifications. Overload The Alpha FXM is overloaded. Remove excess loads. Backfeed A relay inside the Alpha FXM has failed and it cannot be replaced in the field. Contact Alpha Tec

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 52 A typical application of this timer controlled dry contact function is to control a traffic light. When the grid power fails, the Alpha FXM goes into the Inverter mode and continues supplying backup power to the traffic light. Since the batteries supplying the backup power have limited capacity, a timer controlled dry contact is usually config- ured to switch the traffic light into the flashing amber or flashing red mode after a user-defined period to conserve battery power. This setup works fine during non rush hour traffic, but during rush hour, it may be more desirabl

  • 11 017-230-B0 Rev 0810 3.  Site Planning WARNING! Restricted Access: The Alpha FXM must be installed in a restricted area accessible only by qualied service personnel. The Alpha FXM is intended for permanent AC connection only. The only exception is the FXM650(U) model. The Alpha FXM must be correctly grounded for proper operation. Older facilities may have in

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 4 1.  Safety SAVE THESE INSTRUCTIONS: This manual contains important safety instructions that must be followed during the installation, servicing, and maintenance of the product. Keep it in a safe place. Re- view the drawings and illustrations contained in this manual before proceeding. If there are any questions regard- ing the safe installation or operation of this product, contact Alpha Technologies or the nearest Alpha representa- tive. Save this document for future reference. 1.1  Safety Symbols To reduce the risk of injury or de

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 58 The default command can be issued via the RS-232 HyperTerminal or the RS-232 GUI as follows: • RS-232 HyperTerminal – type default:all and press Enter. Enter the password and the Alpha FXM returns *default as confirmation. • RS-232 GUI – From the UPS Maintenance > Unit Configuration screen, click the Restore Defaults button. Enter the password to execute the command. Restoring All Parame ters to Default Values The purpose of this command is to reset the Alpha FXM to the factory default state. See Table P for a list of pa- rameters that will be restored to their default values. CAUTION! This co

  • 017-230-B0 Rev 0810 82 10.5  Using the Spreadsheet Download the spreadsheet “Peukert’s Parameters Calculator.xls” from www.alpha.ca website. Enter the Baery voltage and nominal load From the data sheet of the baeries enter the 2 closest currents and discharge hours Enter the number of parallel strings }

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 40 6.9.10  100-Event Log Up to 100 events are stored in the Alpha FXM’s log. If more than 100 events occur, the oldest is over-written. Procedure 1. To see the log, type event (all lower case) and press Enter. The events are listed starting with the most recent and appear as: If less than 100 events occurred, the last entry will appear as: See below for details on these readouts. eventX=12/25/99 01:45:59 0000000000000000, 0000000000000000, 000 Event Date Time Alarm Fault Mode Date & Time formats de

  • 017-230-B0 Rev 0810 50 Dry contact functions are not programmable through the LCD. Use the RS-232 GUI or the HyperTerminal instead. 2. RS-232 GUI – Figure 26a shows the Relay Configuration window under the UPS Maintenance > Relay & Load Shed screen. As an example, to assign C1 as the Temperature trigger, select Temperature from the drop down menu. Click Update Co

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 68 7.  Maintenance 7.1  Updating the Software The Alpha FXM’s firmware can be reinstalled or updated to the latest version with this procedure. If your Alpha FXM is provided with the factory-installed FXM communication module, the firmware upgrade can be done via an intranet or internet connection. You will need the following items: • RS-232 connection cable to the Alpha FXM. • uBug12 software must be installed. It is available for download at www.alpha.ca\downloads. • Alpha’s firmware must be installed. It can be accessed with your computer and downloaded at www.alpha. ca\downloads. 7.1.1  Procedure 1. Switch of

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 74 7.3  Preventative Maintenance Perform preventative maintenance on the Alpha FXM module every 6 to 12 months. For mission critical applica- tions such as backup traffic intersections, more frequent maintenance should be done. Proper implementation of the following procedure will insure that your system continues to provide reliable backup power in the event of a utility power failure. 7.3.1  Tools and Materials Required • Wrench set. • Labels and marker to number batteries. �

  • Alpha Technologies FXM 650, 43 017-230-B0 Rev 0810 6.9.13  Installation and Set Up The following tools and materials are required: • Alpha UPS Monitor, available for download from www.alpha.ca./downloads/. • Windows 98 or later with Microsoft’s .NET framework installed. • DE–9 serial straight-through computer cable. Procedure 1. Install the Alpha UPS Monitor onto your computer. Restart the computer. If you install the Alpha UPS Monitor on a version of Windows without the .NET framework installed, an

  • Alpha Technologies FXM 650, 83 017-230-B0 Rev 0810 11.  Warranty Alpha Technologies Ltd. warrants all equipment manufactured by it to be free from defects in parts and labor, for a period of two years from the date of shipment from the factory. The warranty provides for repairing, replacing or issuing credit (at Alpha’s discretion) for any equipment manufactured by it and returned by the customer to the factory or other authorized location during the warranty period. There are limitations to this warranty cover- age. The warranty does not provide to the customer or other parties any remedies other than the above. It does not provide coverage for any loss of profits, l

  • 017-230-B0 Rev 0810 62 Upgrade Files This feature is available only on Alpha FXM UPS equipped with the network interface card factory option. To upgrade the Alpha UPS Monitor firmware, browse to the .bin file and click OK to start the upload. This may take a few minutes to complete. Figure 47 — Alpha UPS Monitor: Upgrade Firmware To upgrade the Communication module

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 44 6.10  Operation The various screens are described on the following pages and operate like Web or Windows-type screens. Point and click to change the various functions or fields. The on line indicator shows if you are connected to the Alpha FXM. The Alpha UPS Monitor automatically polls the Alpha FXM to obtain its status. The default setting is polling once every 3 seconds, but you can change this in the UPS Maintenance-Unit Configuration screen in the “Status Refresh Time” menu. If a light or lights are illuminated in the Fault or Alarm fields, the Alpha FXM has a malfunction. Hover yo

  • Alpha Technologies FXM 650, 41 017-230-B0 Rev 0810 6.9.11  Communicating with the Alpha UPS Monitor Introduction The Alpha UPS Monitor graphical user interface (GUI) provides web or Windows© like computer communications with the Alpha FXM. The screen and its features are shown below. It is used to monitor, control and set various parameters like the date and time, determine when to perform the weekly self test, change the relay configura- tions, etc. The Fault or Alarm indicators show if the Alpha FXM has experienced a malfunction and the cause. Descriptions of all the screens and their functions are given in “Operation”. Figure 15 — Alpha UPS Monitor (UPS Specification Screen shown) A

  • Alpha Technologies FXM 650, 35 017-230-B0 Rev 0810 6.9.4  Adjusting and Controlling the Alpha FXM The Maintenance submenu lets you control the Alpha FXM and change selected items to meet your operational needs. Procedure From the Main menu, type 3 and press Enter. Table K — Maintenance Submenu 30 Battery Test Options This starts the battery test and sets how long the test will run. The default setting for the test duration is 2 minutes, but this can be adjusted in 1 minute intervals. See "Operating the Alpha FXM, BATT TEST”. 31 Inverter On/Off This switc

  • Alpha Technologies FXM 650, Visit us at www.alpha.ca Due to continuing product development, Alpha Technologies reserves the right to change specifications without notice. Copyright © 2010 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies. Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC V5J 5M4 Canada Tel: +1 604 436 5900 Fax: +1 604 436 1233 Toll Free: +1 800 667 8743 Alpha Technologies Inc. 3767 Alpha Way Bellingham, WA 98226 United States Tel: +1 360 647 2360 Fax: +1 360 671 4936 Alpha Industrial Power Inc. 1075 Satellit

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 64 Keep Alive status/ma nual cont rol: a. The Status field allows the user to enable or disable the Keep Alive function. When disabled the alarm is cleared. b. The Delay to Startup field allows the user to set the time to the first ping from the enable ping or UPS restart after a ping failure. Minimum = 5 s, Maximum = 3600 s. Keep Alive Method to detect communication failure: a. The Protocol field allows Ping as the only option. b. The IP Address field is used to enter the IP address to be pinged. c. The

  • Alpha Technologies FXM 650, 39 017-230-B0 Rev 0810 6.9.8  Viewing the Serial Number To display the serial number of the Alpha FXM UPS, type "∗QY0" at the command line and press "Enter". 6.9.9  Setting the Peukert Numbe r and Capacity You can set the Peukert Number and Capacity using the RS-232 interface or the web interface. To display the current Peukert Number, type "∗QY6" at the command line and press "Enter". To change the Peukert Number to 1

  • Alpha Technologies FXM 650, 017-230-B0 Rev 0810 8         Battery Breaker This circuit breaker provides over-current protection and is uses as an on/off switch for the battery power. It must be switched on for proper Alpha FXM operation. 2   Battery Connector The battery connector connects the external batteries to the Alpha FXM. 3   Inte rnal Fan This microprocessor-controlled fan regulates the Alpha FXM’s internal temperature for optimum performance. It must not be blocked. If the fan fails, an Alarm is generated. 4   LAN This optional RJ-45 connector is the Alpha FXM’s Ethernet connector.

More Instructions:

DOWNLOAD

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Flight Display Systems FD70CV-M-C-1 Installation and operation manual flight-display-systems/fd70cv-m-c-1-W86.pdf 13 Sep 2023 14
2 Alpha Power 99 Operating manual alpha-power/99-X2B.pdf 15 Jul 2022 53
3 Planar PR9030 User manual – operating manual planar/pr9030-VLV.pdf 05 Aug 2023 78
4 Plantronics M55 Learn more plantronics/m55-836.pdf 29 Feb 2024 7
5 Sony VGN-SZ780 Specifications sony/vgn-sz780-3I5.pdf 05 Jan 2023 2
6 Air King 500CFM Specifications air-king/500cfm-8V4.pdf 11 Feb 2023 1 0.05 Mb

Similar Resources:

  • Steren

    MOV-015

    (2 pages)
    INSTRUCCIONES Antes de utilizar su nuevo producto Steren, lea este instructivo para evitar cualquier mal funcionamiento.IMPORTANTE La información que se muestra en este manual sirve únicamente como referencia sobre el producto. Debido a actualizaciones pueden existir diferencias. Por favor, consulte nuestra página web (www.steren.com) para obtener la ve …
  • BlueWalker

    PowerWalker VFI 1000 TG

    (4 pages)
    ENGLISH PowerWalker VFI 1000-3000 TG/TB/TGS Quick Guide I. Panel Description II. Button Switch Function ON/Silence Button By pressing the ON-Button continuously for more than 1 second the UPS system is turned on. By pressing this Button an acoustic alarm can be deactivated in the battery mode. By short touch this Button all acoustic alarms can be de …
  • Pocasa

    L8K3/1

    (45 pages)
    1 L series 3/1 online UPS (6KVA~80KVA) UUUssseeerrr’’’sss MMMaaannnuuuaaalll PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn …
  • CyberPower

    CSN27U12V

    (2 pages)
    Version: 041019 Backup Power for Home Phone Services During Power Outages Some of our voice services may need a backup battery to avoid disruption of service, and to maintain the ability to call 911, during a power outage. This notice provides information on battery backup requirements and options for obtaining backup batteries. Which services need a backup …
  • Emerson

    GXT4-6000RT230

    (12 pages)
    Liebert® GXT4™ 10000VA RT230 Rack Configuration GUIDE SPECIFICATIONS 1.1 SUMMARY 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements for a continuous- duty, single-phase, solid-state uninterruptible power system (UPS). The UPS shall provide high-quality mains power for sensitive, electronic equi …
  • Tripp Lite

    AVRX Series

    (2 pages)
    Quick Start GuideAVRX Series UPS SystemsNot suitable for mobile applications.This document explains the most important features of your UPS system. For additional information, download the Owner’s Manual PDF (in English, French, German or Russian) from www.tripplite.com/support/manualsInstallation Plug the UPS into an outlet. After plugging the UPS into …

Comments, Questions and Opinions: