  • AAP ESL KIT, PROGRAMMING STARTS Page 2 Changing Entry delay’s Zone 1 is set at 20 seconds by default. This is how long the panel gives you to get in and disarm it after a sensor has been tripped. Each sensor has its own delay from 0 to 9999 seconds. If you have to pass a sensor to get to the keypad then it should have a delay. In Installer Mode press <PROGRAM> <144> <ENTER> (then select the zone you wish to change 1-8) and <ENTER> (then put in the new time 0-9999) and <ENTER>. P 1

  • When you have finished the programming options, a quick test is required to confirm all hardware and software is working correctly. Run through the steps below and tick the box if it operates successfully. Make sure no one is moving around the house, as this could affect the test. 1. The keypad should not have any zone lights on. The ready light should be

  • AAP ESL KIT, Page 4 DIALLER SETUP - FOR MONITORING STATION Your Elite S-Lite Controller is equipped with an on board dialler, capable of communicating in contact id. If you are required to connect to a central monitoring station you will need to complete the following steps. Contact a monitoring station of your choice, they will issue you an account number and telephone number. Name of monitoring station___________________________ Contact phone number_____________ Your Account number [ ][ ][ ][ ] Telephone number

  • AAP ESL KIT, DIALLER SETUP - FOR PERSONAL MONITORING If you don’t want your alarm to be monitored by a security company, but still wish to know if any activations oc- curs, then the Domestic Dial option could be for you. If a phone number on your Elite S-Lite Controller’s is set to Domestic Dial, when an activation occurs that number will be called and siren tone will be played down the line to you. Then you need to acknowledge it by pressing the # key on the phone. Telephone number 1 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] Telephone number 2 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] Telephone number 3 [ ][ ][ ][ ][ ][

  • AAP ESL KIT, E16LED KP Cable Entry Point PCB fits here 17 volt AC power leads HARDWARE CONFIGURATION Page 6 Screw PCB down in these points. BATTERY GOES HERE WIRE 230V MAINS IN HERE. INSIDE VEIW OF PLASTIC CABINET POP OUT CABLE CLAMP FOR MAINS LEAD. End view of Keypad Carefully slide a flat blade screwdriver into slots to remove back. Removing back from keypad. CUT THIS SUPPORT OFF

  • 5 Year Warranty Thank you for purchasing another quality Arrowhead Product. We guarantee to replace or repair Arrowhead Manufactured product found to be faulty due to defective materials or workmanship for a period of 5 years from date of purchase. The customer shall as soon as practicable after the discovery of any such defect or fault, return the goods or de

  • AAP ESL KIT, E16LED KP RESISTOR COLOUR CODES: 2K2 = = RED, RED, RED, GOLD. 4K7 = = YELLOW, VIOLET, RED, GOLD. 8K2 = = GREY, RED, RED, GOLD. SIREN TAMPER LED STROBE EOL SS-1C SATELLITE SIREN ESL CONNECTION DIAGRAM 230V AC Input Lin Dat Clk Neg Pos Gnd 12V 1 C 2 3 C 4 Tmp Gnd Outputs Gnd 12V 1 2 3 4 ELITE S-LITE V908.12 In Lin Out AC AC Red Blk 17VAC Zone 1 Passive Infra-Red Detector 0v 12v EOL TAMPER EOL RELA

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Commell LV-67O Operation & user’s manual commell/lv-67o-144.pdf 11 Mar 2024 41
2 Pioneer AVH-P6600DVD Installation manual pioneer/avh-p6600dvd-4C1.pdf 06 Aug 2022 8
3 Adam Equipment GK series Manual  adam-equipment/gk-series-Z1R.pdf 26 Oct 2022 23
4 LG -E410I Operation & user’s manual lg/e410i-MH2.pdf 03 Sep 2022 220
5 Wen 4286 Operator's manual wen/4286-83C.pdf 28 Nov 2023 16
6 Dinex TSBH2 Operating & maintenance manual dinex/tsbh2-1FZ.pdf 10 Nov 2022 8

Similar Resources:

  • DAVIS

    Vantage Pro2

    (16 pages)
    Vantage PRO2™ Quick Reference Guide Davis Instruments 3465 Diablo Ave, Hayward, CA 94545 U.S.A. Phone (510) 732-9229 • Fax (510) 732-9188 • www.davisnet.com E-mail: [email protected][email protected] Part Number: 07395.235 Rev A (9/17/04) © 2004 by Davis Instruments Corp. All rights reserved. Vantage Pro2 …
  • Honeywell

    LYNX Touch L7000 Series

    (2 pages)
    Ê800-16090V1,Š 800-16090V1 12/14 Rev A Part 1 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2014 Honeywell International Inc. www.honeywell.com/security LYNX Touch L7000 Record a Message Your system can record brief single or multiple messages. The total available recording time is 184 seconds. Function Pres …
  • Q-See

    QC9416-16V2

    (2 pages)
    Contents may differ slightly from images.QC9416-16V2 16-ChannelAnalogHD Security SystemWhat’s in the BoxDVRQC9416 AnalogHD DVRHard Drive Pre-InstalledUSB Mouse HDMIVideo CableRJ45 EthernetCableMounting Screwsand AnchorsOne set per cameraCamerasMissing or damaged parts? Please fill out a request at Q-See.com/Support.Select the “Ask a Question” tab and …
  • ADEMCO

    Vista-10P

    (16 pages)
    9,67$3 3URJUDPPLQJ*XLGH ONOFF1OFF4MAX7INSTANTREADY2AWAY5TEST8CODE03STAY6BYPASS9CHIME#ARMEDREADY1OFF4MAX7INSTANTREADY2AWAY5TEST8CODE03STAY6BYPASS9CHIME#ARMEDREADY ® K0735PRV1 9/02 …
  • teko

    Astra-R

    (4 pages)
    R-v11_5_en 1 «Astra-R» Wireless alarm system Operation Manual This operating manual is intended to study the principle of opera-tion, operating con …
  • Det-Tronics

    OPECL

    (23 pages)
    IMPORTANTBe sure to read and understand the entire instruc-tion manual before installing or operating the gasdetection system. This product is intended to pro-vide early warning of the presence of a flammableor explosive gas mixture. Proper device installa-tion, operation, and maintenance is required toensure safe and effective operation.APPLICATIONThe Ope …

Comments, Questions and Opinions: