  • Panasonic FP7, 3.2 Operation Check Using Logging/Trace Monitor 3.2.2 System Relays Relating to Logging/Trace Operation  System relays Device No. Name Operation SR100 Logging trace active  Turns on during the startup of logging/trace operation. Another system relay allocated to the same LOG number is reset during the start operation.  The logging/trace function is activated by any of the following methods; 1: Autostart setting, 2: Start by instructions, 3: Start by the tool software. Storing data in the buffer is

  • Panasonic FP7, Logging Operation 4-4 4.2 Operation When Logging is Selected for Application 4.2.1 Operation When Logging Operation Starts The following operations are executed when the start operation is requested.  Registered data is confirmed.  Once the logging/trace becomes executable, the logging/trace active flags (SR100, SR110, SR122 ...) turn on. When the logging trigger condition is met under this condition, the logging/trace operation starts.  All other flags than the logging/trace active flag for LOG n are cleared during the start request operation.  Once writing data into an SD memory card becomes enabled after the logging/trace active flags (SR100, SR110, SR

  • Start-Stop and Monitor 3-4 3.2 Operation Check Using Logging/Trace Monitor 3.2.1 Logging/Trace Monitor The progress situation can be confirmed with the logging/trace monitor.  Example of monitoring in logging operation  Example of monitoring on the compl etion of trace operation Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

  • Panasonic FP7, 1.2 Overview of Functions  Image of logging function FP7 CPU Internal memory (RAM) SD Logging buffer memory Log 0 SD memory card Log1 Log 15 2 Sample (130401_120100).csv 3 1 X Sample (130401_120200).csv Sample (130401_120300).csv Sample (13xxxxx_xxxxxx).csv Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

  • Panasonic FP7, Overview of Functions 1-8 1.3 Format of Saved Files 1.3.1 File Format (For Logging Function)  Files are saved in csv format.  For the details of setting methods, refer to 2.2 Logging Information Setting.  CSV format  Time stamp information (year/mon th/day/hour/minute/second) and information of registered devices are saved.  The data length varies depending on the types of specified devices.  Comments can be given at the beginning of data. 1st line 2nd line 3rd line 4th line 5th line 1 2 3 - Data name 1 Data name 2 Data name 3 - Arbitrary comment Arbitrary comment Arbitrar y comment - MOMENT MOMENT MOMENT - Data format 1 Data format 2 Data forma

  • Panasonic FP7, Trace Operation and Time Chart 5-10 5.3.3 Restrictions on Time Chart Monitor The restrictions on the time chart are as follows.  Although a maximum of 16 patterns of trace can be executed (in the case all LOGs are operated for trace application), only one LOG can be displayed on the time chart.  A maximum of 500 devices can be registered for one LOG, however, there are restrictions on devices to be graphically displayed on the time chart. ・In case of contact device: According to the resolution of a display ・In case of data devices: Up to six devices  Time cannot be measured with the cursors (C, R) on graphs when the LOG displayed as a time chart is the data tha

  • Panasonic FP7, Table of Contents 6.2.2 Errors When Operation was Executed Using LOGST, LOGED or SMPL Instruction................................................................................................6-4 6.2.3 Error of Logging/Trace ............................................................................6-5 6.2.4 Error When Copying SD Memory Card...................................................6-5 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

  • Panasonic FP7, Overview of Functions 1-10 1.4 Data Format  The format of the data to be output as logging data and saved in a file varies according to the type of devices.  For the details of setting methods, refer to 2.4 Registration of Device Information.  Device type and data for mat Output type to files Data type No. of occupied words Data type No. of characters Range or sample BIT Bit data 1 word 0 or 1 1 0 or 1 US Unsigned 16- bit integer 1 word Decimal integer (unsigned) 5 0 to 65536

  • 2.6 Downloading Setting Data to CPU Unit 2.6 Downloading Setting Data to CPU Unit 2.6.1 Downloading to Execution Memory RAM/ROM1  Overview  Parameters set in the logging/trace settings menu are downloaded together with programs and configuration data as project data. 2.6.2 Copying from SD Memory Card to Execution Memory RAM/ROM1  Overview  Logging/trace settin

  • Panasonic FP7, Configuration 2-2 2.1 Definition of Buffer Memory 2.1.1 Setting Method  Setting method  Define the buffer memory of the CPU unit to be used for logging/trace.  The buffer memory is set with the tool software FPWIN GR7. PROCEDURE 1. Define the b uffer memory of the CPU unit to be used for logging/trace. The "Logging/Trace Settings" dialog box is displayed. 2. Select a number of div isions of buffer memory from the range of 1 to 16. 3. Double-click on the field of Capacity

  • Panasonic FP7, Trace Operation and Time Chart 5-8 5.3.2 Explanation of Time Chart Monitor The time chart window is composed of the following parts.  Names and functions of parts Mark Name Function A-1 Trace data display area (All devices) Displays the devices registered in the target LOG for the time chart display. ・Select the device to be displayed in graphs from this list. ・Corrensponding data is displayed at the position of the cursor [C] or [R] in the graph display area (B-1). A-2 Trace data display area (Contact devices) ・Contact data selected in A-1 is displayed in this area. ・When a lot of devices are registere

  • 2.1 Definition of Buffer Memory  Setting range Item Default Setting range No. of divisions of buffer memory 16 1-16 LOG0-LOG15 Buffer memory capacity (unit: k word) 64 8-1024 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

  • Panasonic FP7, 3.3 Operation Check Using System Monitor 3.3 Operation Check Using System Monitor 3.3.1 Monitoring Method of System Monitor Area (SM)  By using the system monitor function, the number of written records in a current file, the number of files stored in a folder (number of generations) and the oldest clock data of files stored in the folder can be monitored.  The system monitor area can be monitored with the tool software FPWIN GR7. PROCEDURE 1. Select "Online" > "Displ ay System Monitor Area (SM)" in the menu bar. The system monitor dialog box

  • Panasonic FP7, Troubleshooting 6-2 6.1 Operations When Errors Occur 6.1.1 Operation When Power Supply Turns Off  Operation when power supply turns off  When activating logging/trace, the power off flag during file access SR3F turns on.  The data stored in the buffer of the CPU unit is discarded. NOTE  In case of the middle of file writing, written data or files may be damaged, or the SD memory itself may not be read. 6.1.2 Operation When Errors Occur (Only When Selecting Logging for Application)  Oper

  • Panasonic FP7, Trace Operation and Time Chart 5-2 5.1 Flow of Trace Operation 5.1.1 Operation Flow  Triggers of trace operation and file contents STEP Operation Trigger of operation File in LOG folder File contents 1 Start Tool software operation Instruction Autostart setting Bit device ON Cycle Instruction Bit device ON Cycle Instruction 2 Logging Logging operation continues until the trace stop condition is met. Trace stop When buffer full is set for stop trigger Sample (130401_120000_TRACE).

  • Panasonic FP7, 5.1 Flow of Trace Operation  Flow of trace operation STEP 1: Startup of trac e Operation  The trace operation is started by any of the following methods; Tool software operation, Instruction in a user program, and Autostart setting. STEP 2: Data logging  After the startup of the trace operation, tracing data is executed with a specified condition when the specified trigger condition (bit device ON, cycle, or instruction) is met.  Traced data is stored in the logging buffer memory (RAM) in t

  • Panasonic FP7, Troubleshooting 6-4 6.2 Troubleshooting 6.2.1 Errors When Start/Stop Operation was Executed Using FPWIN GR7 This section describes the messages displayed when the start or stop operation is performed on the "Logging/Trace Monitor" dialog box, and countermeasures.  List of error messages Error message Situation Countermeasures 60 From PLC: Application error - Parameter error Any box of LOG number is not checked. Check the box of the LOG number to be started. 62 From PLC : Application error - Registration error An unregistered LOG number was activated. Check if the settings matches the LOG numb

Related Products and Documents (Control Units):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Mercury SV9100 Operation & user’s manual mercury/sv9100-2Y6.pdf 21 Jul 2023 7
2 Epson T88III - TM B/W Thermal Line Printer Operation & user’s manual epson/t88iii-tm-b-w-thermal-line-printer-215.pdf 06 Jan 2023 10
3 SpeakerCraft BassX Dual 8 Owner's manual speakercraft/bassx-dual-8-FMC.pdf 24 Dec 2023 6 6.73 Mb
4 Draper LFC-20 Instructions draper/lfc-20-M79.pdf 24 Aug 2023 4 1.64 Mb
5 Electrolux TR1240 Installation and use manual electrolux/tr1240-1AC.pdf 16 Jan 2023 12
6 Samsung Galaxy Tab 10.1 GT-P7500V Operation & user’s manual samsung/galaxy-tab-10-1-gt-p7500v-8O2.pdf 25 Dec 2023 113

Similar Resources:

  • Bryant

    SYSTXBBECW01-A

    (68 pages)
    SYSTXBBECW01--A, SYSTXBBECN01--A& SYSTXBBECC01--AEvolutionr Connext ControlOwner’s ManualA12479NOTE: Read the entire instruction manual before starting the installation.The features and functions outlined in this Owner’s Manual reflect Version 13software. See the Downloads section of www.MyEvolutionConnex.Bryant.comforthe latest software release and …
  • Extron electronics

    TLP 350MV

    (4 pages)
    TLP 350MV • Setup GuideOverviewThe Extron® TLP 350MV is a wall-mounted TouchLink™ Panel that provides simple and versatile configuration and control for a range of IP Link® control systems.Graphic and text objects are displayed on the screen. These objects have system control functions associated with them and the Touchpanel allows you to control thos …
  • Extron electronics

    ECP 1000

    (18 pages)
    User’s ManualExtron Electronics, USA1230 South Lewis StreetAnaheim, CA 92805USA714.491.1500 Fax 714.491.1517Extron Electronics, EuropeBeeldschermweg 6C3821 AH AmersfoortThe Netherlands+31.33.453.4040 Fax +31.33.453.4050Extron Electronics, Asia135 Joo Seng Road, #04-01PM Industrial BuildingSingapore 368363+65.6383.4400 Fax +65.6383.4664Extron Electronics …
  • Siemens

    SINAMICS G120

    (42 pages)
    SINAMICS G: Control of a G120 or G110M with an Allen-Bradley controller (Compact/ ControlLogix) via EtherNet/IP SINAMICS G120, G110M https://support.industry.siemens.com/cs/ww/en/view/82843076 Siemens Industry Online Support …
  • OXO

    Mistral 24

    (52 pages)
    INSTRUCTION MANUAL MODE D’EMPLOIFOR YOUR OWN SAFETY, PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE YOU INITIALLY START-UPPOUR VOTRE SÉCURITÉ, MERCI DE LIRE ATTENTIVEMENTCE MODE D’EMPLOI AVANT D’UTILISER VOTRE PRODUITMistral 24V1.0 06/2019 …
  • Viessmann

    VITOSOLIC 100

    (4 pages)
    Operating instructionsfor system usersVITOSOLIC 100, part no.Ă7170Ă925Control units for solar heating systemsFor your safetyPlease follow these safety instructions closely to prevent accidents andmaterial losses.In an emergencyH Immediately isolate the mainselectrical supply, e.g. by removinga separate mains fuse or by meansof a mains electrical isolator(u …

Comments, Questions and Opinions: