Manualios.com

NPower 14714 Owner's Manual

NPower 14714 Manual Online:

4.3, 2927 votes
NPower 14714 User Manual
NPower 14714 User Guide
NPower 14714 Online Manual

Text of NPower 14714 User Guide:

  • NPower 14714, 1 400 Watt Backup Power System Owner’s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Item# 14714

  • NPower 14714, 2 Thank you very much for choosing an NPower™ product. For future reference, please complete the owner’s record below: Model: _______________ Purchase Date: _______________ Save the receipt, warranty and these instructions. It is important that you read the entire manual to become familiar with this product before you begin using it. This item is designed for certain applications only. The distributor cannot be responsible for issues arising from modifica

  • NPower 14714, 3 GENERAL SAFETY RULES WARNING: Read and understand all instructions. Failure to follow all instructions listed below may result in serious injury. CAUTION: Do not allow persons to operate Backup Power Unit until they have read this manual and have developed a thorough understanding of how the unit works. WARNING: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions or situations that could occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. SAVE THES

  • NPower 14714, 4 · Do not use this product wherever there are flammable fumes or gases, such as in the bilge of a gasoline-powered boat or near propane tanks. · Do not use this product in an enclosure containing automotive-type lead-acid batteries. · These batteries, unlike the sealed AGM battery in the Backup Power System, vent explosive hydrogen gas which can be ignited by sparks from electrical connections. · When working on electrical equipment, always ensure someone is nearby to aid you in case of an emergency. WARNING: Heated surface En

  • NPower 14714, 5 · Remove personal metal items such as rings, bracelets, necklaces and watches when working with batteries. Batteries produce a short-circuit current high enough to weld a ring or other similar objects to metal, causing a severe burn. · If you need to remove a battery, always remove the positive terminal from the battery first. Make sure all accessories are off to avoid risk of hazard. · Use safety goggles or safety glasses with side shields which comply with current national standards, or when needed, a face shield. Use as d

  • NPower 14714, 6 CAUTION: Equipment damage Some products, including the types listed below, may be damaged if they are connected to the Backup Power System: · Speed controllers found in some fans · Power tools · Kitchen appliances · Metal halide arc (MHI) lights FEATURES Feature Description 1 Power button: turns Backup Power System ON and OFF when pressed for half a second. · Turning the unit on activates the LED screen and the five AC outlets. When the unit is on, it simultaneously can charge itself and provide backup power while connected to the utility. · NOTE: when the unit is turned off, it will not provide power through the f

  • NPower 14714, 7 4 Select: Button displays Backup Power System battery level (%) or output power (W) 5 LED Screen: indicates charging status, power system battery level (%). The screen also shows error codes to aid troubleshooting. 6 Fault: LED illuminates red when fault condition exists 7 AC power cord 8 Emergency LED light: Illuminates the rear AC outlets when a power outage occurs 9 Five 120 V AC outlets: For powering office equipment and household appliances that draw a maximum total of 40

  • 8 AC outlets of the Backup Power System. 3. Turn on the unit by pressing the power button for half a second. The green AC power LED confirms that the backup power system is ON and ready to provide backup power. When the battery needs recharging, the LED screen flashes “CHg” two times, then the battery capacity (%) once. This pattern of flashing continues until the battery capacity re

  • NPower 14714, 9 Under-voltage shutdown: During backup power operation the battery power has been completely exhausted. No power is available at the AC outlets Fault LED on. Display shows error code F05 Beep continually and the unit shuts down after 10 seconds. Not applicable. Unit starts recharging the internal battery when utility power is restored. Turn on the unit to restore normal operation. Over-temperature warning/shutdown: Unit has shutdown to protect its internal circuitry from high temperatures. Fault LED on. Display shows error code F03 One beep per second. The unit is turned off or when the unit sh

  • 10 Inkjet printer 60 6 hrs. Laptop 75 5 hrs. 13in. TV 230 1 hrs. Desktop computer 300 40 min. *Actual power consumption as measured on sample products. A. Average power consumption as measured on loads tested under regular operating conditions. Check your appliances/devices for actual manufacturer rating since it may vary from averages shown here. B.

  • 11 TROUBLESHOOTING Error codes If the products connected to the Backup Power System do not operate and the alarm is sounding, check the Backup Power System LED screen for an error code. Error code Possible cause Solution F05 Low voltage shutdown because battery is discharged. Recharge battery by plugging the AC power cord into a wall

  • NPower 14714, 12 outlets pushing it fully inward. Products connected to unit lose power Backup Power System has detected an overload condition. Backup Power System has detected an over-temperature condition. Backup Power System has exhausted its available battery power. Make sure the products plugged into the AC outlets are not exceeding 400 W capacity of the unit when supplying backup power. Try removing some of the products. Disconnect products from the AC outlets. Make sure the products plugged into the AC outlets are not exceeding the continuous output power rating of the unit when supplying ba

  • NPower 14714, 13 WARRANTY One-Year Limited Warranty Northern Tool + Equipment warrants this product for one year limited against any defects in materials or workmanship. The defective products will be replaced and repaired at no charge in either of one year. This warranty lasts for 12 months from the date of purchase at the point of sale to you. This warranty does not apply where the product has been misused, improperly installed, physically damaged or altered, either internally or externally, or damaged from improper use. Northern Tool + Equipment will repair or replace the defective

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Garmin LIVE 1695 Quick start manual garmin/live-1695-752.pdf 14 Nov 2023 16 0.63 Mb
2 Sharp XL-UR27H Quick start manual sharp/xl-ur27h-576.pdf 26 Nov 2022 2 0.65 Mb
3 Belkin F5U142 Operation & user’s manual belkin/f5u142-CY7.pdf 06 Jul 2023 19 0.12 Mb
4 Husqvarna R 147 Instruction manual husqvarna/r-147-OW4.pdf 17 Feb 2023 17
5 LST SG70-1 Specifications lst/sg70-1-733.pdf 07 Jan 2024 2
6 Whirlpool WTW4900X Dimensions and installation whirlpool/wtw4900x-U55.pdf 27 Oct 2023 2

Similar Resources:

  • Tripp Lite

    BCPRO600

    (5 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: BCPRO600BC Pro 600VA Tower Standby 120V UPS with USB port Highlights600VA tower 120V standby UPSMaintains AC output during power failures3 UPS battery supported outlets, 3 surge-only outletsUSB port, TEL/DSL/ethernet protection, 97% efficien …
  • PowerWalker

    VI 500 R1U

    (2 pages)
    PowerWalker VI 500/750 R1U User Manual IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. CAUTION! To prevent the ri …
  • Tripp Lite

    OMNIVSINT800

    (5 pages)
    OmniVS 230V 800VA 475W Line-Interactive UPS,USB port, C13 OutletsMODEL NUMBER: OMNIVSINT800DescriptionTripp Lite's OMNIVSINT800 line interactive UPS system offers voltage regulation, surge suppression andlong lasting battery support for personal computers, internetworking equipment and other sensitiveelectronics. Internal UPS circuits support entry leve …
  • Giganet

    Micro Monitor

    (30 pages)
    Giganet Micro Monitor Advanced High-Level SNMP Adapter for UPS User Manual GIGANET NETWORKING SOLUTIONS LTD | 9 De Montfort Street | Leicester | LE1 7GE | UK |Telephone: +44 (0)208 844 2639 Fax: +44(0)844 822 2456 Email: [email protected] Web: www.giga-net.co.uk …
  • CyberPower

    CP825LCD

    (2 pages)
    1 2 364 5Battery Replacement1. Place the UPS on its top and remove the retaining screw (figure 1).2. Slide the battery compartment cover completely off of the unit (figure 2).3. Remove the battery from the compartment and disconnect the battery wires from the battery. Install the replacement battery by connecting the red wire to the positive (+) terminal and …
  • Powercom

    5K VA

    (17 pages)
    5K VA – 12K VA UPS ■User’s and Installation Manual■ IEMC Statements CISPR 22 NOTICE: Pursuant to CISPR 22 rules, this product has been tested and thereby complies to the conditions of a Class A digital device, which have been established for offering sufficient protection against dangerous interference for installation in a re …

Comments, Questions and Opinions: