  • Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-6387 Fax: 408 527-0883 This document includes various trademarks of Cisco Systems, Inc. Please see the Notices section of this document for a list

  • Cisco Prisma II EDR, Connecting Optical Cables OL-32414-01 31 Connecting Optical Cables Cable Routing - Prisma II Chassis Fiber Fish Tool WARNING: Unterminated fiber cables and connectors may emit invisible laser radiation. Avoid direct exposure to the laser light source. Ensure that the fiber cable is terminated before "fishing." The Fiber Fish tool that was shipped with the Prisma II Chassis is used to pull an optical cable from the rear of the chassis to the front of the chassis so the optical cables can be connected to optical connectors on the front panel of the modules. Fiber Fish Tool Hook At the e

  • Cisco Prisma II EDR, Safe Operation for Software Controlling Optical Transmission Equipment OL-32414-01 xv Safe Operation for Software Controlling Optical Transmission Equipment If this document discusses software, the software described is used to monitor and/or control ours and other vendors’ electrical and optical equipment designed to transmit video, voice, or data signals. Certain safety precautions must be observed when operating equipment of this nature. For equipment specific safety requirements, see the appropriate section of

  • Cisco Prisma II EDR, Important Safety Instructions OL-32414-01 xi General Servicing Precautions WARNING: Avoid electric shock! Opening or removing this equipment’s cover may expose you to dangerous voltages. CAUTION: These servicing precautions are for the guidance of qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Be aw

  • Cisco Prisma II EDR, OL-32414-01 39 If You Have Questions If you have technical questions, call Cisco Services for assistance. Follow the menu options to speak with a service engineer. Access your company's extranet site to view or order additional technical publications. For accessing instructions, contact the representative who handles your account. Check your extranet site often as the information is updated frequently. 4 Chapter 4 Customer Information

  • OL-32414-01 1 Overview This chapter describes the Cisco Prisma II Enhanced Digital Return (EDR) Transmitter module and the Cisco EDR 85 System in which it is used. Purpose This guide provides information about the transmitter. This chapter describes the front and back panels, and presents a setup summary for the transmitter. Who Should Use This Document This documen

  • Cisco Prisma II EDR, Chapter 2 System Installation 20 OL-32414-01 Space Requirements This is a double-width, half-height module. Actual space requirements depend on whether the module is installed in a Prisma II standard or a Prisma II XD chassis. Prisma II Standard Chassis Installation When installed in a Prisma II standard chassis, the module is placed in a host module and then inserted into the chassis in an available pair of application module slots, which are generally slot pairs 5-6 through 15-16.  If the module occupies the upper host module position, its slot number is the same (5 through 15) as that of the first

  • Cisco Prisma II EDR, Prisma II Chassis Host Module OL-32414-01 15 Side View Host Module Back Panel Connectors Blind-mate connectors make it easy to install the host module. The push-on connector on the back of the module mates with the back plane bus connector inside the chassis. This 110-pin connector provides the following facilities:  RF signal input connection  Electrical power input connection  Alarm communications connections  Status-monitoring connections  Communications and control connections

  • Cisco Prisma II EDR, Installing the HD Module in the Chassis OL-32414-01 25 Installing the HD Module in the Chassis To Install the Application Modules in the Host Module Important:  All Prisma II high-density application modules must be installed in a host module before they can be mounted in a standard Prisma II Chassis.  Prisma II host modules prior to Rev C (date codes through A2006) do not support the Controller Area Network (CAN) bus.  To support CAN bus redundancy, the ICIM2 must be Rev B or later. Complete the following steps to install the application modules in the host module: 1 Align the ridges on the top and bottom of the m

  • Cisco Prisma II EDR, Index 46 OL-32414-01 P PLL • 43 Power Requirements • 19 Preparing for Installation • 18 Prisma II Chassis Host Module • 14 Prisma II EDR Transmitter Overview • 9 Prisma II Standard Chassis Style • 20 Prisma II XD Chassis Style • 22 Q QAM • 43 R Rear-Access Chassis - Front Panel Illustration • 21 Receiver Operation • 5, 7 Recommended Equipment • 29 RF • 43 RMA • 43 RT • 44 RX • 44 S SBS • 44 Site Requirements • 19 SMC • 44 SNMP • 44 Space Requirements • 20 System Block Diagram • 4

  • Cisco Prisma II EDR, Chapter 1 Module Introduction 4 OL-32414-01  Enables independent balancing of reverse traffic at EDR receiver ports  Simplified setup reduces installation time and expertise requirements  Distance- and temperature-independent link performance simplifies engineering and maintenance requirements  Space-saving, high-density deployment in Prisma II or Prisma II XD chassis increases deployment cost-efficiency  Monitoring of transmitter parameters available at the receiver As with the legacy bdr multiplexing system, the EDR 85 System leverages 2:1 multiplexing to reduce fiber usage. System Block Diagram The foll

  • Cisco Prisma II EDR, OL-32414-01 45 A About the OPM • 12 ac, AC • 41 Access Requirements • 19 Additional Assistance • 38 AGC • 41 B Back Panel Connectors • 12 bdr • 41 C Cable Routing - Prisma II Chassis • 31 Cable Routing - Prisma XD Chassis • 32 CAN • 41 Cleaning Optical Connectors • 29 Configuration Summary • 16 Connecting Optical Cables • 31 Connecting the RF Cables to the Chassis • 23 Customer Information • 18, 38, 39 D dc, DC • 41 DFB laser • 41

  • Cisco Prisma II EDR, Chapter 1 Module Introduction 14 OL-32414-01 Prisma II Chassis Host Module A standard Prisma II Chassis host module is required to mount high density application modules in a standard Prisma II Chassis. The host module doubles the density of the Prisma II Chassis by providing two high density module slots for each current Prisma II slot. Its simple design allows for efficient routing of RF and electrical signal between the chassis back plane and each high density module. For the Prisma II EDR Transmitter with Integrated Transmitter Host Module, the chassis accepts two

  • Cisco Prisma II EDR, Chapter 3 Maintenance and Troubleshooting 38 OL-32414-01 Transmitter Module Troubleshooting Chart Symptom Possible Cause Possible Solutions No optical signal output (ALARM LED is Red) The laser temperature could be too high or low. Allow up to one minute after power is ON for the temperature to stabilize. If still no output, contact Cisco Services for assistance. The laser could be faulty. Contact Cisco Services for assistance. Automatic power control circuit

  • Cisco Prisma II EDR, Chapter 2 System Installation 32 OL-32414-01 5 Disengage the optical cable from the Fiber Fish tool and attach to the appropriate connector on the desired module. Cable Routing - Prisma XD Chassis Feed each fiber through the fiber tray located beneath the Prisma XD Chassis. The fiber tray slides in and out to facilitate routing. To Connect Optical Cables to Module Important: Observe laser safety precautions. See Laser Safety information earlier in this guide. Note: This procedure assumes that the chassis is mounted in a rack and that fiber optic cable has been run to the chassis front panel

  • Cisco Prisma II EDR, Important Safety Instructions OL-32414-01 v Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Only use attachments/accessories specified by the manufacturer. Read and Retain Instructions Carefully read all safety and operating instructions before operating this equipment, and retain them for future reference. Follow Instructions and Heed Warnings Follow all operating and use instructions. Pay attention to all warnings and cautions in the operating instructions, as well as those that are affixed to this equipment. Terminology The terms defined below are used i

  • Chapter 2 System Installation 26 OL-32414-01 To Install the Module in the Chassis Note: This procedure assumes that the chassis is mounted in a rack. 1 Locate the fiber guides at the bottom of the chassis and the module guide slots inside the chassis as shown in the following illustration. 2 Align the ridges on the top and bottom of the host module with the guide slots o

  • Cisco Prisma II EDR, Chapter 2 System Installation 24 OL-32414-01 4 Connect RF cables to the Port B and Port D connectors for the chassis slot in which the module will be installed. These are the RF output connections for the module in the upper half-slot position. Hand-tighten the connectors. 5 Route the RF cables from Ports B and D (for the upper half-slot module) to the appropriate RF destinations. 6 If F connectors are installed, use a 7/16-in. open-end wrench to secure all cables to the connectors at the chassis. Prisma II XD Chassis 1 Attach a 75

  • Chapter 1 Module Introduction 10 OL-32414-01 Transmitter Optical Input The optical input is a dual LC/PC connector in an OPM. Laser Warning WARNING: Avoid damage to your eyes! Do not look into any optical connector while the system is active. Even if the unit is off, there may still be hazardous optical levels present.

  • Cisco Prisma II EDR, Chapter 2 System Installation 30 OL-32414-01 To Clean Optical Connectors Warning:  Avoid personal injury! Use of controls, adjustments, or procedures other than those specified herein may result in hazardous radiation exposure.  Avoid personal injury! The laser light source on this equipment (if a transmitter) or the fiber cables connected to this equipment emit invisible laser radiation.  Avoid personal injury! Viewing the laser output (if a transmitter) or fiber cable with optical instruments (such

  • Cisco Prisma II EDR, Connecting Optical Cables OL-32414-01 33 4 Install the fiber optic jumper provided between the OPM connector and the front panel optical output connector, as shown below. Note: To ensure the proper bend radius, be sure to route the fiber through the clips as shown. 5 Insert the transmitter end of the appropriate fiber optic cable into its receptacle on the transmitter front panel. 6 Route the other end of the fiber optic cable to the appropriate destination.

  • Cisco Prisma II EDR, EDR 85 System Overview OL-32414-01 5 System Description The Cisco EDR system is a set of long-haul transport products for CATV reverse path applications. The system is designed to transport analog reverse path spectra from hub or headend to hub or headend over optical fiber. Reverse path signals are typically DOCSIS and DAVIC data. At the transmitter, one or two analog reverse path signals occupying the 5 - 85 MHz reverse band spectrum are sampled by an analog-to-digital converter (ADC). A high-speed serial data stream is constructed by scrambling and framing the data. This data stream is carried optically over fiber to a remote hub

  • Cisco Prisma II EDR, Important Safety Instructions xii OL-32414-01  Avoid touching electronic components when installing a module. Fuse Replacement To replace a fuse, comply with the following:  Disconnect the power before changing fuses.  Identify and clear the condition that caused the original fuse failure.  Always use a fuse of the correct type and rating. The correct type and rating are indicated on this equipment. Batteries This product may contain batteries. Special instructions apply regardin

Related Products and Documents (Transmitter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 American Standard Silhouette 7183.801 Specification sheet american-standard/silhouette-7183-801-AC3.pdf 21 May 2023 2
2 Mitsubishi DIAMOND PRO 900U NFJ9905SKHUW Operation & user’s manual mitsubishi/diamond-pro-900u-nfj9905skhuw-3L3.pdf 06 Nov 2022 40
3 Polk Audio UltraFit 1000 Owner's manual polk-audio/ultrafit-1000-93B.pdf 03 Nov 2022 9
4 AT&T E1126 Operation & user’s manual at-t/e1126-3QT.pdf 31 Oct 2023 59 8.13 Mb
5 NEC Express5800/120Rf-1 Operation manual nec/express5800-120rf-1-IM6.pdf 12 Jan 2024 21
6 ViewSonic P95f - 19" CRT Display Specifications viewsonic/p95f-19-crt-display-HMH.pdf 09 Oct 2022 2 0.18 Mb

Similar Resources:

  • KP Electronic Systems

    SIM900

    (2 pages)
    MATC™ Mini Alarm Transmitter Cellular Installation Manual Web Site: www.kpsystems.com ISRAEL Office Email: [email protected] Tefen Industrial Park, Tefen 24959 Tel: 972-4-987-3066 Fax: 972-4-987-3692 USA Office: KP ELECTRONICS INC. Email: [email protected] 415 Sargon Way Suite F Horsham PA 19044 Tel: (215) 442-7460 Fax: (215) 442-7461 P.N.: Book 13 …
  • Cooper Menvier

    520r

    (2 pages)
    1. 520r PIRIntroductionThe 520r Passive Infra Red (PIR) is an indoor detector designed to work with the 500r wire free control panel. The PIR detects movement. The detector has a fan shaped sensitive area approximately 10 metres in radius.The case is protected by an internal tamper switch.SpecificationPart No. 520rEUR-50Power Supply 2 x AA alkaline cellsB …
  • Status Instruments

    SEM110

    (2 pages)
    D2133_01_04 CN5082 SEM110 User Guide 1.0 GENERAL The SEM110 series are high performance two wire (4 to 20) mA transmitters designed to accept most standard industrial temperature, thermocouple, slide wire and variable resistance sensors which operate over most common ranges. Automatic thermocouple cold junction compensation is provided on thermocouple ve …
  • Lectronics

    IFBT4/E01-VHF

    (16 pages)
    IFBT4-VHFFrequency-Agile Compact IFB TransmitterIFBT4-VHF, IFBT4/E01-VHF, IFBT4-VHF/XINSTRUCTION MANUALRio Rancho, NM, USAwww.lectrosonics.comFill in for your records: Serial Number: Purchase Date:Featuring Digital Hybrid Wireless® TechnologyU.S. Patent 7,225,135 …
  • KAM

    Bodypack V2

    (4 pages)
    MADE IN CHINA Due to continuous product development, please ensure that you have downloaded the latest instruction manual for this product from the Kam website at www.kam.co.uk MANUAL VERSION 1.0 05- 03- 12 For the latest updates and information on the entire Kam range visit: www.kam.co.uk Kam products are manufactured by: …
  • Jogler

    JLT-6000 series

    (16 pages)
    6646 Complex Drive | Baton Rouge, LA 70809 | Phone: 225-456-2495 | Toll Free: 1-800-223-8469 | [email protected] | www.jogler.comPage 1JLT-6000 .IOMM.REV 001 (06.2007) WWW.JOGLER.COM PAGE 1 __________________________________________________________________________________Installation and Operating Manual …

Comments, Questions and Opinions: