Text of Fujitsu Eternus DX200F User Guide:

  • Fujitsu Eternus DX200F, How Warnings are Presented in This Manual A message is written beside the symbol indicating the caution level. This message is marked with a vertical ribbon in the left margin, to distinguish this warning from ordinary descriptions. A display example is shown here. Warning level indicator Warning type indicator Warning details • To avoid damaging the ETERNUS DX, pay attention to the following points when cleaning the ETERNUS DX: - Make sure to disconnect the power when cleaning. - Be careful that no liquid seeps into the ETERNUS DX when using cleaners, etc. - Do not use alcohol or other solvents to

  • Fujitsu Eternus DX200F, 11.2 Performance/Tuning ■ Solution Overview The performance of existing systems may be affected when the number of servers that access the ETERNUS DX increases due to increased operations. The process performance that the user sets as the target value can be automatically adjusted by using ETERNUS SF Storage Cruiser to automate QoS. This guarantees the band- width for a server according to the operation priority to reduce the effect on one server from another server, which results in the performance of a server with high

  • Fujitsu Eternus DX200F, 3.4.2 LAN Related Specifications ■ Network Communication Protocols The usable LAN ports and functions are different depending on the usage and protocol. The following table shows how the LAN ports may be used (by usage and protocol). Table 3.2 LAN Port Availability Usage Protocol tcp / udp Port number Direction Master CM Slave CM Remarks MNT RMT MNT RMT ETERNUS Web GUI http / https tcp 80 / 443 from ¡ ¡ △ (*1) △ (*1) Accessed from a Web browser ETERNUS CLI telnet / ssh tcp 23 / 22 from ¡ ¡ △ (*1) △ (*1) − f

  • Fujitsu Eternus DX200F, 6 Select the radio button of the volume that is to be used, and then click the [OK] button. Select the "No.: 1, Name: sdv0" volume. 7 Check the displayed information, and then click the [Start] button. 8 In the confirmation screen, click the [OK] button. The SnapOPC+ session starts. 9 Click the [Done] button to return to the [Advanced Copy] screen. Chapter 9 Advanced Copy Settings 9.2 Performing a Copy (SnapOPC+) 122 FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic) Copyright 2014 FUJITSU LIMITED P3

  • Fujitsu Eternus DX200F, 7.3 Wake On LAN Settings A network environment needs to be set to receive magic packets that are used by Wake On LAN for the ETER- NUS DX. The procedure to set Wake On LAN is as follows. 1 On the navigation of the ETERNUS Web GUI screen, click [System]. The [System] screen appears. 2 In [Category], click [Network]. The [Network] screen appears. 3 In [Action], click [Setup Network Environment]. The [Setup Network Environment] screen appears. 4 In the [Setup Network Environment] screen, select [Enable] for [Wake On LAN]. • For operations with cluster connections, set the IP address of the Slave CM for the &qu

  • Fujitsu Eternus DX200F, AC power is supplied to the ETERNUS DX and the POWER LED on the power supply unit blinks green. Power supply unit (PSU#1)Power supply unit (PSU#0) POWER LED 5.2.2 Powering On Turn on the PC terminal and the ETERNUS DX. Follow the procedure below to turn on the ETERNUS DX. • After turning the power on, it takes approximately two minutes for the ETERNUS DX to be in READY state (READY LED ( ) turns on). If an error is detected in a component during the initial power-on diagnos- tics, it may take a longer time (up to ten minutes) for the ETERNUS DX to be in a READY state. • After power-off, wait for about one minute before turning power on again. 1 Press the Power swi

  • Fujitsu Eternus DX200F, 1 On the navigation of the ETERNUS Web GUI screen, click [System]. The [System] screen appears. 2 In [Category], click [System Settings]. The [System Settings] screen appears. 3 In [Action], click [Setup Power Management]. The [Setup Power Management] screen appears. 4 In the [Setup Power Management] screen, select [Enable] for [Auto Power], [Power Resume], or both. 5 Click the [Set] button. A confirmation screen appears. 6 Click the [OK] button. The Auto Power function and/or the Power Resume function setting is applied. 7 Check the setting completion message and click the [Done] button. The screen display returns to the [System Sett

  • Fujitsu Eternus DX200F, Do • When connecting the host interface cables, position them so that they will not obstruct replacement of the power supply unit or controllers by the main- tenance engineer. 2 Connect the host interface cable to the connection destination. Connect the other end of the cable to the connection destination. 4.2 Power Synchronized Unit Connection When using a power synchronized unit for power control, connect the power synchronized unit to the ETER- NUS DX. Refer to "Configuration Guide (Power Synchronized Un

  • Fujitsu Eternus DX200F, 6 Click the [Set] button to apply the specified settings. A confirmation screen appears. 7 Click the [OK] button. The event notification settings are applied. 8 Check the setting completion message and click the [Done] button. The screen display returns to the [Event/Dump] screen. 6.2 Various Notification Settings To monitor an ETERNUS DX, perform the required settings for device error notification. 6.2.1 SNMP Trap Setup SNMP Trap can be sent to the SNMP Manager (monitoring server) when an event occurs in the ETERNUS DX. The SNMP Trap setting is explained below. Careful

  • Fujitsu Eternus DX200F, Chapter 4 Connecting Cables This chapter explains how to connect various cables to the ETERNUS DX. Do • Make sure to wear a wrist strap or discharge static electricity by touching a metal object before starting each operation, as failure to discharge static electricity may cause device failure. 4.1 Host Interface Cable Connection Connect the ETERNUS DX to the connection destination using host interface cables. The connection procedure varies depending on the type of host interface that is used for the ETERNUS DX. Prepare the same number of host interface cables as the number of host interface ports. This section uses an iSCSI 10Gbit/s host interface (CA) a

  • Fujitsu Eternus DX200F, Preface Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS DX200F All Flash Array (herein- after referred to as ETERNUS DX). The ETERNUS DX is designed to be connected to Fujitsu servers (Fujitsu M10, PRIMEQUEST, or PRIMERGY) or non-Fujitsu servers. This manual describes all the procedures that are required to start operation of the ETERNUS DX. This manual is intended for use of the ETERNUS DX in regions other than Japan. Please carefully review the information outlined in this manual. First Edition May 2014 About This Manual Organ

  • Fujitsu Eternus DX200F, 4 The currently set initiator name is displayed. Click the [Change] button. 5 On the [iSCSI Initiator Name] screen, specify the initiator name and click the [OK] button. To leave the initiator name unchanged, click the [OK] button. To use the default initiator name, also click the [Change] button. This allows you to continue to use this initiator name even after changing the "server name". Chapter 3 Checking the Configuration Environment 3.2 Server Connection Preparation 26 FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-8462-01ENZ0

  • Fujitsu Eternus DX200F, Chapter 10 System Status Check Check the status of the ETERNUS DX on the ETERNUS Web GUI screen or ETERNUS CLI. 10.1 Component Status Check The status of the ETERNUS DX can be checked by general status in the upper left of the ETERNUS Web GUI screen. When the general status image is " ", the ETERNUS DX is in normal status. When the general status image is other than " " (" ", " ", etc.), an abnormality has been detected in the ETER- NUS DX. Check the status of

  • (5) Check the setting completion message and click the [Done] button. The screen display returns to the remote support screen. 4 Confirm the connection of the ETERNUS DX and the AIS Connect server in the remote support center. (1) In [Action], click [Test Server Connectivity]. A confirmation screen appears. (2) Click the [OK] button. The connection with the server is checked.

  • Fujitsu Eternus DX200F, Chapter 9 Advanced Copy Settings This chapter explains the required setting to perform an Advanced Copy. This chapter also provides a proce- dure on how to perform an Advanced Copy. 9.1 Advanced Copy Basic Settings This section describes the basic settings to use Advanced Copy. 9.1.1 Copy Priority Settings Specify the copy priority by using the EC (*1) and OPC (*2) functions. To set the copy priority, the host I/O load and the copy processing load must be taken into consideration. The specified copy priority is applied not only to the next session, but also to the existing session. *1: An EC includes ECs and RECs with direct connections. *2: An OPC includes OPC, QuickOPC, SnapOPC,

  • 5.7.3 Generation Management Volume (SDV) Creation Create a generation management volume in the backup RAID group. Create SDV for seven generations (as a backup area for seven days a week) in the backup RAID group "RG1" created in "5.7.1 RAID Group Creation" (page 49). Figure 5.7 Generation Management Volume (SDV) Creation Backup RAID group (RG1) Ge

  • 8.2 Server Connection Setup............................................................................................................... 93 8.2.1 iSCSI Initiator Parameter Settings (Connection Information Settings).................................................................93 8.2.2 LUN Recognition Check.......................................................

  • Fujitsu Eternus DX200F, 5.7.5 Hot Spare Registration Register the hot spare for the failure of a drive. The following two types of hot spare are available: • Global Hot Spare This is available for any RAID group. • Dedicated Hot Spare This is only available to a specified RAID group. For a RAID group that contains important data, assign "Dedicated Hot Spare" in order to preferentially use the hot spare. Do Not • Do not uninstall the drives that are installed by default or move them to any other slot. Contact your sales representative or maintenance engineer if drives that are instal- led by default need to be uninstalled or moved to another slot. ■ Global Hot Spare Registration The p

  • 2 When the RMT port is used, connect the connector of the LAN cable to the RMT port of Controller 0 (CM#0) and Controller 1 (CM#1). 3 Connect the LAN cables of the MNT port to the network of the customer. If the RMT port is used for remote support, connect the LAN cable of the RMT port to the network for remote support. 5.6 Firewall Settings Set the firewall for each service. The

  • Fujitsu Eternus DX200F, The LUNs that are set with the ETERNUS DX are recognized as [Offline]. 3 Right-click all the disks displayed as offline, and select [Online]. Chapter 8 SAN Connection Settings 8.2 Server Connection Setup 105 FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-8462-01ENZ0

  • Chapter 11 Solution Configuration This chapter describes the optimum solutions provided by the ETERNUS DX linking with software programs. 11.1 Continuous Business ■ Solution Overview The ETERNUS DX can perform real time data transfers from the operation site to a remote site. Even if an error occurs in the operation site, operations can continue by switching operation from

  • 3.4 LAN Connection Preparation for Operation Management 3.4.1 Completing and Attaching the Network Settings Label Enter the network setting information on the Network Settings label. Attach the Network Setting label on the rack wall near the ETERNUS DX to avoid losing it. Figure 3.2 Network Setting Label Network Setting : : . .

  • Fujitsu Eternus DX200F, • Maintenance Secure This service is enabled for connections from things such as monitoring software or for using the re- mote support function to download firmware between storage systems. SSH encrypts and sends/receives data. • SNMP This service is enabled when an ETERNUS DX is connected via the SNMP manager. • RCIL This service is enabled when an RCIL Power Synchronized Connection is used. • ETERNUS DX Discovery Change the setting to "Disable". 6 Click the [Set] button. 7 In the confirmation screen, click the [OK] button. The firewall settings are applied. 8 Check the setting completion messa

  • Fujitsu Eternus DX200F, 2 Check the result of the test transmission. Check that the SNMP Trap is notified to the monitoring server. For details on the messages for test transmission, refer to "Message List". If the SNMP Manager cannot receive an SNMP test trap, check that the network has no trouble, and the settings for the ETERNUS DX are correct. • Is the LAN between the monitoring server and ETERNUS DX connected correctly? Execute the "ping" command from the monitoring server, and confirm the reply from the ETERNUS DX. When "ICMP" is disabled

  • Fujitsu Eternus DX200F, To use bidirectional CHAP authentication, the CHAP user name and password must be entered. A confirmation screen appears. 4 Click the [OK] button. The port parameter is set and the setting completion screen appears. 5 Click the [Done] button. The screen display returns to the [iSCSI Port Group] screen. Chapter 8 SAN Connection Settings 8.1 Connection Settings for the ETERNUS DX 87 FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-8462-01ENZ0

  • Fujitsu Eternus DX200F, *1: Enter the capacity of the copy source volume during creation of SDV. *2: If "7" is specified for the number of volumes, sdv0, sdv1, sdv2, sdv3, sdv4, sdv5, and sdv6 volumes are created. A confirmation screen appears. 4 Click the [OK] button. The volume is created and the registration completion screen appears. 5 Click the [Done] button. The screen display returns to the [Volume] screen. 5.7.4 Temporary Work Volume (SDPV) Creation Create a temporary work volume in the backup RAID group. Create a volume as an expansion area of SDV in the backup RAID group "RG1" created in "5.7.1 RAID Group Creation" (page 49). Figure

  • Fujitsu Eternus DX200F, Perform the settings as shown below. Drive File system that is to be created LUN Volume No. Volume name Type Capacity (*1) G RAW 1 1 sdv0 SDV (1TB) H RAW 2 2 sdv1 SDV (1TB) I RAW 3 3 sdv2 SDV (1TB) J RAW 4 4 sdv3 SDV (1TB) K RAW 5 5 sdv4 SDV (1TB) L RAW 6 6 sdv5 SDV (1TB) M RAW 7 7 sdv6 SDV (1TB) *1: The capacity that is displayed in "( )" is the copy source capacity. 5 Select [Do not format this volume], and click the [Next] button. 6 [Completing the New Simple Volume Wizard] appears. Click the [Finish] button. Chapter 8 SAN C

  • Fujitsu Eternus DX200F, 16 Use the same method to open the remaining seven copy destination drives to check if those files that were created in Step 15 are displayed. Old data can be restored by simply copying and pasting the data files that are to be restored from the server. Chapter 9 Advanced Copy Settings 9.2 Performing a Copy (SnapOPC+) 125 FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-8462-01ENZ0

  • Fujitsu Eternus DX200F, The procedure to create a temporary work volume (SDPV) is as follows: 1 Click the [Volume] tab on the navigation of the ETERNUS Web GUI screen. The [Volumes] screen appears. 2 In [Action], click [Create]. The [Create Volume] screen appears. 3 Set the required items in the [Create Volume] screen and click the [Create] button. Name: sdpv Capacity: 500GB Type: Snap Data Pool Volume RAID group / TPP setting: Manual Manual setting: RG1 A confirmation screen appears. 4 Click the [OK] button. The volume is created a

  • Fujitsu Eternus DX200F, The ETERNUS DX and the PC terminal must be connected directly since the network environment of the ETERNUS DX is set using the PC terminal for the initial setup of the ETERNUS DX. Figure 5.3 PC Terminal Connection for Initial Setup PC terminal LAN cable LAN port RMT port of Controller 0 (CM#0) 5.2 Powering On This section explains how to turn on the ETERNUS DX. 5.2.1 Switching On and Off the PSU Switch on the Power Supply Unit Move the PSU switches of the power supply unit in the ETERNUS DX to the ON position (marked "|

Related Products and Documents (Disk array system):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HELIX X-JUST Operating instructions helix/x-just-5B6.pdf 02 Jul 2023 2 0.12 Mb
2 Lynx C AD 5320 D Reference manual lynx/c-ad-5320-d-V38.pdf 10 Sep 2022 33
3 Mr. Heater MH125FAV Operating instructions and owner's manual mr-heater/mh125fav-HMW.pdf 07 Dec 2022 12
4 HP 3740 series Owner's manual hp/3740-series-3U8.pdf 07 Feb 2024 78
5 Planet FT-902 Operation & user’s manual planet-technology/ft-902-B36.pdf 28 Jan 2024 40
6 Kuppersbusch EEB 6600.5 Instructions for use and installation instructions kuppersbusch/eeb-66005-5E7.pdf 07 Jul 2023 26

Similar Resources:

  • Addonics Technologies

    RAID Tower IX RT93SDEU3

    (5 pages)
    Technical SupportIf you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at:Hours: 8:30 am - 6:00 pm PSTPhone: 408-453-6212Email: http://www.addonics.com/support/query/www.addonics.comT E C H N O L O G I E SRAID Tower IX(RT93SDEU3)User Guide …
  • Dell

    MD3000

    (66 pages)
    www.dell.com | support.dell.comDell™ PowerVault™MD3000 SystemsInformation Update信息更新Mise à jour des informationsAktuelle Informationenアップデート情報설명서 갱신본Actualización de información …
  • HP

    XP10000

    (54 pages)
    HP StorageWorksXP Disk Array Configuration Guide for IBM AIXHP XP24000 Disk ArraynlHP XP20000 Disk ArraynlHP XP12000 Disk ArraynlHP XP10000 Disk ArraynlHP 200 Storage Virtualization SystemAbstractThis guide provides requirements and procedures for connecting an XP disk array or SVS 200 to a host system,and for configuring the disk array for use with the AIX …
  • easyRAID

    Q12QS-4GR2

    (32 pages)
    easyRAID Q12QS-4GR2Hardware User Manual 42-30000-5104iSCSI 1Gb to SASDisk Array SystemVersion 1.1 …
  • HP

    P9000

    (4 pages)
    HP StorageWorks P9000 VirtualizationAdapter Release NotesThis document contains supplemental information for the P9000 Virtualization Adapter. The information in thisdocument supplements and/or supersedes all other documentation pertaining to the use of the P9000 VirtualizationAdapter.Part Number: 5697-0681Third edition: October 2010 …
  • NetApp

    FAS8200 Series

    (125 pages)
    MaintainONTAP SystemsNetAppNovember 23, 2021This PDF was generated from https://docs.netapp.com/us-en/ontap-systems/fas8200/bootmedia-replace-overview.html on November 23, 2021. Always check docs.netapp.com for the latest. …

Comments, Questions and Opinions: