Manualios.com

Bloomfield E. B. C. Electronic Brew Control Owner's Manual

  • E. B. C. Electronic Brew Control Coffee Maker
  • mazsro3ZnXAZY
  • Owner's Manual
  • PDF / Adobe Acrobat Reader
  • 32

Bloomfield E. B. C. Electronic Brew Control Manual Online:

3.55, 1596 votes
Bloomfield E. B. C. Electronic Brew Control User Manual
Bloomfield E. B. C. Electronic Brew Control User Guide
Bloomfield E. B. C. Electronic Brew Control Online Manual

Text of Bloomfield E. B. C. Electronic Brew Control User Guide:

  • Bloomfield E. B. C. Electronic Brew Control, SERVICING INSTRUCTIONS (continued) 17 REPLACE SOLENOID Unplug power cord. Turn OFF and disconnect water supply from brewer inlet tting. Remove front panel. Remove two screws holding access door in place. Remove access door and solenoid. Unscrew inlet tting cap to release solenoid from door. Remove wiring from solenoid. Large end of wrench 86660 can be used to hold solenoid inlet tting while disconnecting supply line. REPLACE FAUCET SUPPLY HOSE Unplug power cord. Turn OFF and disconnect water supply from brewer inlet tting. Disconnect hose tting from solenoid (See illustration at right). Disconnect hose are tting fro

  • Bloomfield E. B. C. Electronic Brew Control, 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket and Spray Disk are properly installed. LEVELING THE UNIT Verify that an adjustable leg is installed at each corner of the brewer. Set Brewer in its operating location.

  • Bloomfield E. B. C. Electronic Brew Control, CLEANING INSTRUCTIONS 11 PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove and empty decanters. 3. Remove and empty brew chamber. 4. Remove the spray disk from the brew head (See gure 8): Press up on the spray disk ears, then turn the disk to the left to unlatch. Remove the gasket from inside the brew head. 5. Wipe inside of brew head and area around the brew head with a

  • Bloomfield E. B. C. Electronic Brew Control, EXPLODED VIEW & PARTS LIST HOT WATER TANK ASSEMBLY 22 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual ITEM PART NO. DESCRIPTION USED ON 13 2C-70134 Hold Down Strap All 14 2C-70133 Nut, 8-32 SS Acorn All 16 2C-40366 Screw, 1/4-20 X 1-1/4 SS Cap Head All 17 DD-49401 Nut, 1/4-20 SS All 50 2J-73644 Temperature Probe All 52 2I-73731 Seal Washer All 54 2I-70147 Tank Cover Gasket All 56 2I-70152 Seal Gasket All 58 2N-70149 Hot Water Coil All 59 2K-70101 Inlet Elbow All 60 2V-70102 Vent Tube All 61 2K-70103 Outlet Elbow All 6

  • Bloomfield E. B. C. Electronic Brew Control, SERVICING INSTRUCTIONS (continued) IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. owing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line. IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on ange of lid. DO NOT OVER-TIGHTEN. IMPORTANT: When replacing temperature probe, be sure a new seal washer is in place around the probe. Tighten jamb lock nut only enoug

  • Bloomfield E. B. C. Electronic Brew Control, 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual WIRING DIAGRAM (continued) 27 E.B.C.™ BREWER MODEL VOLTS WATTS AMPS 1086 115/230 3500 15 1088 115/230 3500 15 KEY PAD P1 1 1 1 CONTROL BOARD P2 8 POWER BOARD NEUTRAL IN VALVE B HEATER B VALVE A LINE IN HEATER A BLACK 12 ga BLACK 12 ga BLACK 12 ga WHITE 12 ga BLACK 12 ga RED 12 ga RED 12 ga 6 5 2 BLACK WHITE INLET VALVE .5 GPM CHASSIS GROUND TEMPERATURE PROBE HI LIMIT 4 3 HEATING ELEMENT 10 7 1A 2A 3A 4B 5B 6B POWER SWITCH 1 9 2

  • Bloomfield E. B. C. Electronic Brew Control, CAUTION: CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualied and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank. IMPORTANT: DO NOT allow any internal components to come into contact with the deliming solution. Take care to keep all internal co

  • WARNING: SHOCK HAZARD Live electrical circuits may be exposed while performing these procedures. These procedures are to be performed by qualied technical personnel only. ERROR DETECTION 13 WHAT TO CHECK DESCRIPTION CORRECTIVE ACTION Has the water tank been properly lled? On initial startup, an attempt to heat a dry tank will be detected as too high a temperat

  • Bloomfield E. B. C. Electronic Brew Control, 8 OPERATION (continued) ELECTRONIC FEATURES Energizing the Brewer When electric power is applied to the unit, all the lights will ash four times and four beeps will sound. The unit will be off. Press the ON/OFF key. Four beeps will sound and all lights will ash once. The POWER indicator will remain on. If the water temperature is more than 10ºF below the setpoint, the HEAT indicator will glow until water temperature reaches setpoint. Press the ON/OFF key again to turn the brewer off. Three beeps will sound, the tank heater and all warmers will be switched off, and all indicator lights will go out. Brew Settings See pages 15 & 16

  • REPLACE HOT WATER FAUCET COIL (Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.) Remove tank lid assembly per above. Remove two hex nuts hot water coil to cover. Pull coil from mounting holes. Reassemble in reverse order. REPAIR HOT WATER FAUCET Remove top panel and turn faucet valve OFF. Unscrew aerator cap from faucet and remove handle

  • Bloomfield E. B. C. Electronic Brew Control, PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualied service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualied personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury. WA

  • Bloomfield E. B. C. Electronic Brew Control, ELECTRICAL COMPONENTS EXPLODED VIEW & PARTS LIST (continued) 23 ITEM PART NO. DESCRIPTION USED ON 30 2E-72936 Switch, Rocker 125/250V 1086, 1088 31 2C-74859 Keypad All 36 2E-70353 Cord & Cap Assembly 1080, 1082 36t 2E-70709 Terminal Strip 1086, 1088 37 2K-70215 Strain Relief 1080, 1082 45 2V-70124 Valve-Sol, 120V Metal All .75GPM 2E-Z16608 Solenoid Bypass, 120V, .30GPM All .30GPM 2E-75753 Solenoid Bypass, 120V Plst. .50GPM All .50GPM 50 2J-73644 Temperature Probe All 63a 2T-47499 Hi-Limit Thermostat 1080, 1082 63b 2T-70716 Hi-Limit Thermostat 1086, 1088 67 2N-72299UL Heating Element (120V, 1800W) 1080, 1082, 1082XL 2N-70143UL Heating E

  • Bloomfield E. B. C. Electronic Brew Control, NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person. 2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage. 3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unp

  • Bloomfield E. B. C. Electronic Brew Control, SERVICING INSTRUCTIONS WARNING: SHOCK HAZARD Opening access panels or removing warmer plates on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel. ACCESS PANELS TOP PANEL: Remove top panel to access hot water tank, thermo probe, heating elements, brew circuit tubing, faucet valve and piping. Top panel is held by two screws at the rear and a retaining lip at the front. FRONT PANEL: Remove front panel

  • Bloomfield E. B. C. Electronic Brew Control, WIRING DIAGRAM 26 KEY PAD P1 1 1 CONTROL BOARD P2 5 POWER BOARD NEUTRAL IN VALVE B HEATER B VALVE A LINE IN HEATER A 1 4 BLACK BLACK 14 ga WHITE 14 ga BLACK WHITE 3 2 BLACK WHITE INLET VALVE .5 GPM CHASSIS GROUND TEMPERATURE PROBE HI LIMIT HEATING ELEMENT E.B.C.ô BREWER MODEL VOLTS WATTS AMPS 1080 120 1800 15 1082 120 1800 15 1080CA 120 1500 12 1082CA 120 1500 12 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual

  • Bloomfield E. B. C. Electronic Brew Control, BREWING COFFEE CAUTION: BURN HAZARD Exposed surfaces of the brewer, brew chamber and airpot or server may be HOT to the touch, and can cause serious burns. CAUTION: BURN HAZARD To avoid splashing or overowing hot liquids, ALWAYS place an empty airpot or server under the brew chamber before starting the brew cycle. Failure to comply can cause serious burns. CAUTION: BURN HAZARD After a brew cycle, brew chamber contents are HOT. Remove the brew chamber and dispose of used grounds with care. Failure to comply can cause serious burns. NOTE: The brewer will not initiate a second automatic brew cycle until the current cycle plus the drip-out time

  • Bloomfield E. B. C. Electronic Brew Control, SERVICING INSTRUCTIONS (continued) 19 Fig. 19Keypad Ribbon Cable Hook-Up SET CONTROLLER JUMPERS Placing the jumper across Q1 sets Quality Time at 20 Minutes. Placing the jumper across Q2 sets Quality Time at 30 Minutes. Removing jumpers from both Q1 or Q2 disables Quality Timer. Placing the jumper across V1 sets Valve Time Range to 60 - 180 seconds. Removing jumper from V1 sets Valve Time Range to 10 - 80 seconds. REPLACE KEYPAD Unplug power cord or turn circuit breaker OFF. Shut off water supply valve. Remove top and front panels. Remove faucet from basin body. Disconnec

  • Bloomfield E. B. C. Electronic Brew Control, TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomeld appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life. This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum performance. WARRANTY STATEMENT xi SPECIFICATIONS

  • Bloomfield E. B. C. Electronic Brew Control, 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual EXPLODED VIEW & PARTS LIST (continued) CABINET COMPONENTS 25 ITEM PART NO. DESCRIPTION USED ON 21 2A-43201 Spacer .171 ID x .375 LG 1082XL 22 A6-77192 Positioning Bracket 1082XL 33 2I-70139 Spray Head Gasket All 34 A6-72727 Spray Disk All 34a A6-70163 Spray Head Retainer All 70 2P-70053 Button Plug (Timer) All 71 2P-72159 Cap, Plastic, Lower Support 1” x 1-1/2” All (except 1082XL) 2P-7479

  • OPERATION (continued) 7 WATER HEATER Water temperature is sensed by an electronic water temperature probe inserted into the water tank. This temperature signal is fed to the controller. The setpoint temperature is adjustable. The controller sends a command signal to the power board based upon a comparison between the setpoint temperature and actual temperature. See page 15. T

  • Bloomfield E. B. C. Electronic Brew Control, 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.com p/n 2M-75872 Rev. H M642 120224 642 OWNERS MANUAL for E. B. C.™ Electronic Brew Control ™ AIRPOT AND THERMAL SERVER COFFEE BREWERS MODELS 1080 1082 1082XL 1086 1088 Includes: Installation Use & Care Servicing Instructions Model 1082 Brewer with optional 7752 Airpot E.B.C.™ brewers are protected under U. S. Patent # 5, 704,275 Other U. S. and Canadian

  • Bloomfield E. B. C. Electronic Brew Control, OPERATION (continued) Quality Timer is normally set for 30 minutes. It can be set for 20 minutes by moving a jumper on the controller. See page 19. After Hours™ is an energy saving feature. The brewer will enter After Hours™ mode if it is not used for three hours. Press the BREW key to immediately return the brewer to normal operation. IMPORTANT: If the original cause of the problem has not been addressed, the brewer will once again go into Over Temperature mode four minu

  • Bloomfield E. B. C. Electronic Brew Control, OPERATION 6 Fig. 4 Brewer Operation Diagram START-UP For initial start-up, or if the brewer has not been used for an extended period of time: • Be sure spray disk and brew gasket are properly installed in the brew head. • Be sure the water supply is properly connected and the water supply valve is turned ON. • Be sure the WATER TANK IS FILLED BEFORE plugging the brewer into a receptacle, or otherwise connecting brewer to electrical power THE WATER TANK MUST BE FILLED. Place an empty decanter under the brew head. Lift the pour-over cover then pour wa

  • SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Remove button plug from front panel. Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power. Place empty container under brew chamber. Energize brewer and pour one decanter (64 oz.) of cold

Related Products and Documents (Coffee Maker):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Image Fitness 933 Manual  image-fitness/933-M3D.pdf 07 Apr 2023 16
2 TriStar SA-1122 Instruction manual tristar/sa-1122-MZ7.pdf 29 Aug 2023 68
3 Sony VPCP114KX/G Specification sheet sony/vpcp114kx-g-419.pdf 13 Oct 2022 2
4 Zanussi DS 10 Instructions for the use & care zanussi/ds-10-4M8.pdf 12 Jan 2024 20 1.31 Mb
5 Epson WorkForce WF-7510 Operation & user’s manual epson/workforce-wf-7510-4GP.pdf 10 Sep 2022 344 4.1 Mb
6 Faber Relaxed Premium L Installation manual faber/relaxed-premium-l-UWD.pdf 26 Nov 2022 24

Similar Resources:

  • Philips

    RI9752/11

    (40 pages)
    FOR HOUSEHOLD USE ONLYUSAGE DOMESTIQUE SEULEMENTOperation and maintenance manualBefore using the machine, please read the attached operating instructions.Carefully read the safety rules.Mode d'emploiVeuillez lire attentivement le mode d'emploi (notamment les consignes de sécurité) avant d'utiliser l'appareil. …
  • Nespresso

    Jura

    (11 pages)
    Das Gerät erst nach dem Lesen dieser Anleitung in Betrieb nehmen! – Für Sicherheitshinweise umblättern!Ne mettez l'appareil en marche qu'après avoir pris connaissance de ce mode d'emploi! – Tournez la pagepour lire les consignes de sécurité!Read this manual before operating the equipment! – For security instructions turn over the p …
  • DeLonghi

    Coffee machine

    (5 pages)
    11Read this manual thoroughly before installing andusing the appliance.This is the only way to ensure best results andmaximum safety for the user.DESCRIPTION(see figure on page 3).The terminology below will be used repeatedly on thefollowing pages.1 Filter holder for ground coffee2 Large filter for 2 cups ground coffee 3 Small filter for 1 cup ground coffee …
  • DeLonghi

    EAM4000 Series

    (28 pages)
    Any questions, please call our Customer Service Department at 1-800-322-3848 (U.S. Only)Monday – Friday: 8:30 – 5:00 (EST) or visit our web site at www.delonghi-espresso.comDes questions? Veuillez appeler notre service à la clientèle au 1-888-335-6644ou visitez notre site Web consacré à www.delonghi-espresso.com.Para cualquier información, le rogamo …
  • Crown

    CEM-1518

    (8 pages)
    INSTRUCTION MANUAL COFFEE MAKER MODEL:CEM-1518 Read this booklet thoroughly before using and save it for future reference …
  • Jura

    Z6

    (20 pages)
    Elektroapparate AG Disassembling manual Technical Support Language EN Z6 OT TFT Author: Patrik Studer Checked: Approved: Docu.-name: Demontageanleitung_Z6_EN.docx L:\Geräte\Linie_Z_Neu\Z6_OT_TFT\Schulungsunterlagen\E\Demontageanleitung_Z6_EN.docx Date: Rev. A: Rev. B: Rev. C: Rev. D: Rev. E: Rev. F: 30.04.2015 Page 1/20 Table of contents: …

Comments, Questions and Opinions: