Manualios.com

Healthy Climate UV-500 Homeowners Manual & Dealer Installation Instructions

  • UV-500 Air Cleaner
  • maxB4DAemxc.s
  • Homeowners Manual & Dealer Installation Instructions
  • PDF / Adobe Acrobat Reader
  • 11

Healthy Climate UV-500 Manual Online:

4.35, 2610 votes
Healthy Climate UV-500 User Manual
Healthy Climate UV-500 User Guide
Healthy Climate UV-500 Online Manual

Text of Healthy Climate UV-500 User Guide:

  • Healthy Climate UV-500, HEALTHY CLIMATE ® GERMICIDAL LIGHT 505,031M 2005 AIR CLEANERS/ FILTERS HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE ® MODELS UV-500, UV-1000, UV-2000 Shipping and Packing List Required Tools and Unique Supplies General Package 1 of 1 contains: 1 - Healthy Climate ® germicidal unit 1 - UVC lamp (UV-2000 contains 2 lamps.) 1 - Power cord 1 - Remote door interlock switch with 5 ft(1.5m) power cord (UV-2000 Only) 1 - Self-adhesive gasket/template 5 - Sheet metal screws with lockwashers 1 - Installatio

  • Healthy Climate UV-500, 2 Dimensions/Specifications DIMENSIONS: Model UV-500 - 11" L x 7" W x 2.5" H (279mm x 178mm x 63mm) Model UV-1000 - 11" L x 7" W x 2.5" H (279mm x 178mm x 63mm) Model UV-2000 - 17" L x 7" W x 2.5" H (432mm x 178mm x 63mm) All models use 16"(406mm) lamp lengths. ELECTRICAL: 120 volt, 250V/3 Amp fuse, detachable 6' (1.8m), three-prong, power cord. POWER CONSUMPTION: Model UV-500 - 55 Watts (Magnetic Ballast) Model UV-1000 - 56 Watts (Electronic Ballast) Model UV-2000 - 108 Watts (Electronic

  • 3 Clearances and Requirements SPECIAL INSTALLATION NOTES: G Do not install in closet return applications. G Do not install in rooftop/outdoor applications. G Do not expose wiring or plastic parts to UVC light. G Do not install device with vents facing down. G Do not install device beneath a humidifier or source of water. G If the UVC device is installed near an air filter, check wit

  • Healthy Climate UV-500, 4 INSTALLING THE DEVICE (Fig. 2) Draw a level line positioned where the top of the device is to be located. Align the top of the self-adhesive gasket to the duct. Use the gas- ket as a template for drilling the viewport and lamp holes. Two lamp holes are required for Model UV-2000. Use a drill bit or holecutter to make the 1"(25mm) lamp hole(s) required. Use a 1/4"(6mm) drill bit for drilling the viewport hole. Remove the cover of the device and attach the base to the gasket and duct using included sheet metal screws. For installations on duct- board use appropriate mounting method. INSTALLING T

  • Healthy Climate UV-500, 5 Installation Electrical Safety Hazard. Can cause injury or death. Do not alter power cord. Any alteration is a violation of ETL and UL listing and will void the Lennox warranty. WARNING Ultraviolet (UVC) Radiation Hazard. Any exposure will cause significant eye damage and may cause skin damage. Do not look into UV light source. Wear UV eye and skin protection. Access panels must be in place during appliance operation. DANGER Fig. 4 Attach connector to lamp. If the connector does not attach eas

  • 6 Installation Model UV-500 Internal Wiring Model UV-2000 Internal Wiring Model UV-1000 Internal Wiring Operation For optimal performance, continuous operation of the UVC germicidal lamp and the air handler blow- er is recommended. IF continuous operation of the air handler is NOT selected, the UVC germicid- al lamp CAN be operated continuously. Continuous operation of the air

  • Healthy Climate UV-500, 7 Maintenance LAMP REPLACEMENT(Annually) The lamp should be replaced annually even if it appears to be operating normally. UVC energy production diminishes over time. 1. Obtain the correct replacement lamp for your Healthy Climate ® model. 2. Disconnect power to the device. 3. Open the cover of the device. Allow lamp to cool 10 minutes before touching. 4. Disconnect the lamp connector. 5. Unscrew the two knurled knobs of the lamp retaining bracket and slide the bracket away from the lamp retaining lip. 6. Carefully remove th

  • Healthy Climate UV-500, 8 FUSE 5 4 3 6 2 1 No. Description UV-500 UV-1000 UV-2000 1 Base Gasket/Template 64X42 64X42 64X64 2 Lighted On/Off Switch 64X50 64X50 64X50 3 Ballast 64X38 64X62 64X62 4 Cover Interlock Switch 64X45 64X45 64X45 5 Fuseholder 64X48 64X48 64X48 6 Fuse 64X49 64X49 64X49 Replacement Parts Not Illustrated Complete Unit w/Lamp(s) X4571 X4573 X4575 UVC Replacement Lamp 64X36 64X56 64X56 Lamp O-Ring 64X41 64X41 64X41 Cover with Label 64X39 64X59 64X63 Power Cord 64X47 64X47 64X47 Remote Door Interlock Switch 64X53 64X53 64X53 1 Model UV-200

  • Healthy Climate UV-500, 9 Installation This copy to be retained by customer. All items were included in the shipping box and have been installed (see Shipping and Packing List). Danger label installed on door to air handling unit. (See Fig. 6) Additional Danger label installed, if necessary. (See Fig. 6) Note: If exposure to the UVC light is possible in any other situation (e.g. when duct panel is removed), the additional enclosed Danger label must be installed in a visible location near the site where the exposure may occur. Turn off room lights w

  • Healthy Climate UV-500, 10 Installation This copy to be retained by installing dealer. All items were included in the shipping box and have been installed (see Shipping and Packing List). Danger label installed on door to air handling unit. (See Fig. 6) Additional Danger label installed, if necessary. (See Fig. 6) Note: If exposure to the UVC light is possible in any other situation (e.g. when duct panel is removed), the additional enclosed Danger label must be installed in a visible location near the site where the exposure may occur. Turn off room lights while the UVC germicidal light is oper

More Instructions:

DOWNLOAD

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP R/T2200 Installation instructions manual hp/rt2200-4UX.pdf 24 Jan 2024 7
2 Fluke VT02 Manual  fluke/vt02-631.pdf 27 Jul 2022 2
3 Pentax S55 Connection manual pentax/s55-14F.pdf 07 Jul 2022 2 1.35 Mb
4 Whirlpool WFE324LWB0 User instructions whirlpool/wfe324lwb0-9L9.pdf 29 Jan 2023 12
5 Polycom Polycom VVX 500 Quick start manual polycom/polycom-vvx-500-3R8.pdf 01 Feb 2024 2
6 Automatic Technology GDO-9v2 SecuraLift Installation instructions manual automatic-technology/gdo-9v2-securalift-5E1.pdf 27 Dec 2022 36

Similar Resources:

  • Karcher

    SC 952

    (9 pages)
    Register and win!www.karcher.com59638140 03/12SC 952΍ΔϳΒήόϠ 186 Deutsch 5English 11Français 17Italiano 24Nederlands 31Español 38Português 45Dansk 52Norsk 58Svenska 64Suomi 70Ελληνικά 76Türkçe 83Русский 89Magyar 96Čeština 102Slovenščina 109Polski 115Româneşte 122Slovenčina 128Hrvatski 134Srp …
  • Holmes

    HAP116

    (2 pages)
    WARRANTY INFORMATIONTROUBLESHOOTING 1 YEAR LIMITED WARRANTYSunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada) Limited doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of one year from the date of purchase, this product will be free from defects in mat …
  • WELLISAIR

    WADU-02

    (11 pages)
    Air Disinfection Purifier WADU-02 User Manual * Before using, it is highly recommended that you read this user manual. * Product out-look and specification might be changed without notice for the product improvement. * Design and color would be different from a cover design. …
  • Briggs & Stratton

    204400

    (20 pages)
    COPYRIGHT by BRIGGS & STRATTON CORPORATIONAll rights reserved. No part of t his material may be reproduced or transmitted,in any form or by any means, electronic or mechanical, including photocopying,recording or by any information storage and retrieval system, without permissionin writing from Briggs & Stratton Corporation.PRINTED IN U.S.A.FORM MS-- …
  • Honeywell

    HA150E

    (29 pages)
    GB TRUE HEPA AIR PURIFIER User InstructionsCZ ČISTIČKA VZDUCHU S TRUE HEPA FILTREM Návod k používáníDE ECHTER HEPALUFTREINIGER GebrauchsanweisungDK TRUE HEPA LUFTRENSNING BetjeningsvejledningEE EHTNE HEPAÕHUPUHASTAJA KasutusjuhendES PURIFICADOR DE AIRE HEPA Instrucciones de manejoFI TRUE HEPA ILMANPUHDISTIN KäyttöohjeFR PUR …
  • Dyson

    Pure Hot+Cool HP00

    (92 pages)
    OPERATING MANUALРУКОВОДСТВО ПО ЭКСПЛУАТАЦИИPRIRUČNIK ZA UPOTREBUNÁVOD K POUŽITÍHASZNÁLATI UTASÍTÁSINSTRUKCJA OBSŁUGIPREVÁDZKOVÁ PRÍRUČKAPRIROČNIK ZA UPORABOASSEMBLYСБОРКАSASTAVLJANJEMONTÁŽÖSSZESZERELÉSMONTAŻMONTÁŽSESTAVNI DELIREGISTER YOUR GUARANTEE TODAYВЫ МОЖЕТЕ ЗАРЕГИСТРИРОВАТЬ И� …

Comments, Questions and Opinions: