  • CHUNLAN FRD23, Exploded view & dismantling sequence of parts - 28 - 3. Dismantling sequence of indoor unit of FR(D)180/S and FR(D)260/S (1) Remove 1; (2) Remove 2; (3) Remove 8, 4; (4) Remove 14, 16 (5) Remove 23; (6) Remove 7; (7) Remove 3; (8) Remove 5; (9) Remove 22. Annex: Dismantling sequence of typical parts Indoors right motor capacitor (seen from air exhaust): (1) Loosen tapping screw on retainer 26, rotate retainer 26; (2) Remove right small hole cover plate assembly 10 (3) Remove capac

  • CHUNLAN FRD23, Installation - 76 - (6) Thermal insulation layer shall be stuck on air delivery ducts and no leakage shall exist at connections. 2. Recommended cross sectional area of air ducts Model FR(D)95 FR(D)125/S FR(D)180/S FR(D)260/S FR(D)71-B FR(D)100-B Return air duct CS area (m 2 ) ≥0.3 ≥0.4 ≥0.6 ≥0.7 ≥0.225 ≥0.3 Air delivery duct CS area (m 2 ) ≥0.135 ≥0.15 ≥0.27 ≥0.325 ≥0.101 ≥0.135 Note: FRD23-B, FRD35-B and FRD50-B can be directly connected to air delivery/return ports via soft connection. Refer to indoor unit installation dimensions for size of air delivery/retu

  • Air duct design & noise reduction - 87 - delivery/return port and air delivery/return hose, for isolation of vibration. Problem 2: Unreasonable design of air speed Careful design of air speed at air delivery/return main duct, branch duct and ports according to conditioned area noise requirement and unit air delivery static pressure is not carried out, causing higher air speed

  • CHUNLAN FRD23, Method of operation - 89 - Chapter X Method of operation I. Description of wire controller 1. Ordinary wire controller Power ON/OFF key ● When power is turned on, power indicator (red) lights up and the unit is in stop status. ● Press power ON/OFF key, the unit will be in ventilating status (high air flow) and temperature is set at 22℃. At this time, use functional key to select operating status. With unit in operating status, press power ON/OFF key will stop the unit and place it in standby status. ● After pressing power ON/OFF k

  • Installation - 70 - 3. Installation mode for indoor unit (1) Installation mode for FR95-C and FR125-C/S (based on upper return air) ● Determine positions of lifting hooks As shown above, ①, ②, ③ and ④ are lifting hook installation positions for FR95-C and FR125-C/S. Suitable positions can be selected to needs. Just select one out of ② and ③. ⑤ refers to the

  • CHUNLAN FRD23, Exploded view & dismantling sequence of parts - 7 - II. Exploded view and dismantling sequence for outdoor unit of FRD23-B, FRD35-B & FRD50-B 1. Exploded view of outdoor unit of FRD23-B, FRD35-B and FRD50-B Exploded view of outdoor unit of FRD23-B, FRD35-B and FRD50-B Outdoor unit

  • CHUNLAN FRD23, Exploded view & dismantling sequence of parts - 6 - 3. Dismantling sequence of indoor unit of FRD23-B, FRD35-B and FRD50-B (1) Remove 18 (2) Remove 17, 19 (3) Remove 12 (4) Remove 11 (5) Remove 16 (6) Remove 14, 8 (7) Remove 9, 13 (8) Remove 10 (9) Remove 15 (10) Remove 7, 6 (11) Remove 20 (12) Remove 21, 4 (13) Remove 5 (14) Remove 3, 1 (15) Remove 2. Annex: Dismantling sequence of typical parts Indoor capacitor (1) Remove 12 (2) Remove capacitor. Indoors motor: (1) Remove fan section rear plate 12 (2) R

  • CHUNLAN FRD23, Typical case analysis - 109 - Chapter XIII Typical case analysis Case I: A user installed a number of FR125/S air duct type air conditioners and complained about poor heating effect. Pressure measurement showed that indoor unit and outdoor unit systems were normal without clogging or leakage, and indoor area and thermal insulation met requirements. Analysis: (1) The indoor unit was installed in ceiling layer of toilet with ventilating windows. Fresh air leaked into return air so that indoor unit return air temperature in winter was lower than 0℃; (2) Insulation on air delivery hose and static pressure box was merel

  • CHUNLAN FRD23, Maintenance - 94 - Chapter XI Maintenance ● To place the unit in outage, first stop the air conditioner and then turn off power switch. ● After long operation of outdoor unit, dust will accumulate on surface of heat exchanger, lowering heat transfer efficiency and hence unit performance. Use long hair brush or compressor air to clean such surface. ● Cleaning cycle of indoor strainer depends on installation position and environment. Frequently clean indoor strainer to avoid failure. Indoor units of FR(D)95, FR(D)125/S, FR(D)180/S, FR(D)260/S, FR95-C and FR125-C/S are complete with strainer. Indoor units of o

  • CHUNLAN FRD23, Main technical parameters - 34 - Chapter III Main technical parameters I. Main technical parameters of FRD23-B, FRD35-B and FRD50-B Model FRD23-B FRD35-B FRD50-B Rated cooling capacity W 2300 3500 5000 Rated heating capacity W 2300(850) 3500(1200) 5000(1500) Power supply 220V~50Hz Cooling W/A 890/4.1 1340/6.2 1950/8.9 Rated input Power/Curr Heating W/A 790(850)/3.6(4.0) 1320(1200)/6.0(5.5) 1850(1500)/8.4(6.8) Air flow (indoor unit) m 3 /h 420 600 800 Static exhaust air pressure Pa 20 Indoor unit kg 24 25.5

  • CHUNLAN FRD23, Exploded view & dismantling sequence of parts - 17 - 2. Exploded view schedule of indoor unit of FR95-C and FR125-C/S No. Descri p tio n Remar k 1 Cover p late assembl y 2 To p p late assembl y 3 Liftin g hoo k 4 Electric box assembl y 5 Left su pp ort p late 6 Small side p late assembl y 7 Fixin g su pp ort assembl y 8 Fixin g su pp ort cover p late assembl y 9 S p iral casin g assembl y 10 Centrifu g al im p elle r 11 S

  • CHUNLAN FRD23, List of main parts & wear parts - 61 - 4. List of main parts & wear parts of FR95-C and FR125/S-C Size/Model Symbol Description FR95-C FR125-C/S PCB1 Main control board ------ ------ PCB2 Wire controller ------ ------ PCB3 Remote controller ------ ------ RT1 Temperature sensor 3324 3324 RT2 Temperature sensor 3324 3324 RT3 Temperature sensor 3324 3324 C1 Capacitor CBB61A 5μF/AC 450V CBB61A 8μF/AC 450V C2 Capacitor CBB611A 6μF/AC 450V CBB611A 8μF/AC 450V C3 Capacitor CBB65A 60μF/AC 450V ------ C4 Capacitor CBB65A-1K 50μF/AC450V ------ Communication line RF10AW/FG.000.01 RF10AW/FG.0

  • Exploded view & dismantling sequence of parts - 14 - 2. Exploded view schedule for FR(D)71-B outdoor unit No. Descri p tio n Remar k 1 Front p anel assembl y 2 Axial flow fan 3 Moto r 4 Motor su pp ort assembl y 5 Condense r 6 Left p anel 7 To p cover assembl y 8 Air intake g ratin g 9 Baffle p late assembl y 10 Ri g h

  • CHUNLAN FRD23, Exploded view & dismantling sequence of parts - 23 - VIII. Exploded view and dismantling sequence of outdoor unit of FR(D)95, FR(D)125/S, FR(D)100-B, FR95-C and FR125-C/S 1. Exploded view of outdoor unit of FR(D)95, FR(D)125/S, FR(D)100-B, FR95-C & FR125-C/S Exploded view of outdoor unit of FR(D)95, FR(D)100-B, FR(D)125/S, FR95-C, FR125-C/S (example of FR(D)95) Outdoor unit

  • CHUNLAN FRD23, Installation - 68 - FR(D)95, FR(D)125/S a(mm) b(mm) c(mm) d(mm) e(mm) FR(D)95 655 300 698 FR(D)125/S 865 400 618 330 908 FR(D)71-B, FR(D)100-B Code Model a(mm) b(mm) c(mm) d(mm) e(mm) FR(D)71-B 1200 1160 1230 FR(D)100-B 1820 226 515 1780 1850

  • CHUNLAN FRD23, Troubleshooting - 105 - Phenomena Method of correction No heating function Check for normal temperature sensor RT1; Check for normal DC12V, DC5V power supply; Check for reliable output port connection of compressor, reversing valve, ID fans and OD fans; Check for main control board damage Check for correct reversing of reversing valve Reversing valve failure Check for intact connection of outdoor unit wiring terminal; Check for damaged main control board; Check for bad contact at ID/OD connecting cable

  • CHUNLAN FRD23, Circuit diagrams - 57 - L: Power supply phase line N: Power supply zero line 9. FR125/S signal line terminals (1) Outdoor fan motor (high speed) (2) 3-phase power supply phase A (3) Reversing valve coil (4) Outdoor fan motor (medium speed) (5) Outdoor fan motor (low speed) (6) Power supply zero line (7) Compressor AC contactor coil (8) 3-phase power supply phase B (9) 3-phase power supply phase C 10. FR125-C/S and FRD125/S signal line terminals (1) Outdoor fan motor (high speed) (2) Outdoor fan motor (medium speed) (3) Reversing valve coil

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 X-GLOO 4x4 Operation & user’s manual x-gloo/4x4-VU1.pdf 01 Jan 2024 25
2 Chevrolet Impala 2016 Owner's manual chevrolet/impala-2016-YK9.pdf 14 Jan 2024 377
3 Westerbeke WMD 7.7 Specifications westerbeke/wmd-7-7-UEP.pdf 15 Sep 2023 4
4 Philips CKW7740N Manual  philips/ckw7740n-7WE.pdf 20 Nov 2023 1
5 TAC Matchless Manual  tac/matchless-4I8.pdf 13 Feb 2023 25
6 Kichler Lighting Jade 300030 Instruction manual kichler-lighting/jade-300030-UFT.pdf 11 May 2023 30

Similar Resources:

  • Lennox

    LCH Series

    (72 pages)
    ©2019WARNINGImproper installation, adjustment, alteration, service or maintenance can cause property damage,personal injury or loss of life. Installation and service must be performed by a licensed professionalHVAC installer or equivalent, service agency, or thegas supplierTable Of ContentsDimensions Page 2.................................Parts Arrang …
  • Carrier

    40MBC/38MAQ

    (20 pages)
    40MBC / 38MAQCassette Ductless Split SystemSizes 09 to 18Installation InstructionsNOTE: Read the entire instruction manual before starting theinstallation.TABLE OF CONTENTSPAGEPARTS LIST 2.......................................SAFETY CONSIDERATIONS 3.........................SYSTEM REQUIREMENTS 4...........................DIMENSIONS 5......................... …
  • AC

    MGA0800/A1

    (16 pages)
    Air Conditioner User Manual MODEL: MGA0800/A1 My innovation We share ●Before using the product, please be sure to read the manual carefully ●Be sure to keep this manual properly so that you can access it at any time in the future. ● On the basis of fully understanding the conten …
  • Fujitsu

    AIRSTAGE AJY072LALBH

    (26 pages)
    EnglishOUTDOOR UNITPART NO. 9378945180-02[Original instructions]DeutschAUßENGERÄTTMFrançaisEspañolUNITÉ EXTÉRIEUREUNIDAD EXTERIORItalianoUNITÀ ESTERNAΕλληνικάPortuguêsΕΞΩΤΕΡΙΚΉ ΜΟΝΆΔΑUNIDADE EXTERIORРусскийTürkçeВНЕШНИЙ МОДУЛЬDIŞ ÜNİTEAJY072LALBHAJY090LALBHAJY108LALBHAJY126LALBHAJY144LALBHAJY162LALBHAJH …
  • Gree

    GUD71PH/A-T

    (78 pages)
    Owner's Manual Original Instructions Air Conditioners DC Inverter U-match Series Duct Type Unit Models: Indoor Unit Outdoor Unit GUD35P/A-T GUD35PS/A-T GUD35W/NhA-T GUD50P/A-T GUD50PS/A-T GUD50W/NhA-T GUD71P/A-T GUD71PS/A-T GUD71W/NhA-T GUD71PH/A-T GUD71PHS/A-T GUD71W/NhA-T GUD85P/A-T GUD85PS/A-T GUD85W/NhA-T GUD85PH/A-T GUD85PHS/A-T GUD85W/NhA-T GUD100 …
  • Unitary products group

    LA300

    (32 pages)
    NOTES, CAUTIONS AND WARNINGSInstaller should pay particular attention to the words:NOTE, CAUTION, and WARNING. Notes are intended toclarify or make the installation easier. Cautions are given toprevent equipment damage. Warnings are given to alertinstaller that personal injury and/or equipment damagemay result if installation procedure is not handled properl …

Comments, Questions and Opinions: