  • IT Watchdogs SA-1, 1 SA-1 Smoke Alarm A smoke alarm is an excellent safety device – and with the IT Watchdogs’ SA-1, not only will you have the usual audible alarm signal if something in your installation begins to smoke, but your WeatherGoose monitoring system will be able to notify you via e-mail or SNMP as well, just like any other monitored sensor! This makes the SA-1 an especially valuable add-on for monitoring remote installations which might not have anyone around to hear the siren. Plus, since the Kidde smoke alarms the SA-1 is based around are capable of being connected to other smoke alarms as a group, su

  • 2 The SA-1 is powered both by a 120VAC wall plug, and by a 9V backup battery which keeps the unit alive and functioning in the event of a line-power failure. This means that as long as your WeatherGoose and its associated network & internet gateways are also kept alive via a UPS or auxiliary generator during a power failure, then you will still receive e-mails and/or

  • IT Watchdogs SA-1, 3 Ÿ Connecting the SA-1 to the Analog-Input terminals: The following diagrams demonstrate how to connect your SA-1 Smoke Alarm directly to the spring-loaded analog-input terminals used on most of the standard series-I and series-II WeatherGoose product lines. (Note that specialized models, such as the PowerGoose and RelayGoose, use different styles of terminal blocks; while the connections will be the same electrically, the mechanical nature of the connector will be different than the one shown here. If necessary, refer to the manuals for those specific models for further details on how

  • 4 Ÿ Sensor operation and behavior: Once you’ve successfully connected the SA1 to your WeatherGoose, the internal-sensors display block of the Sensors page will look something like this: (NOTE: for purposes of this example, the SA-1 has been connected to Analog Input #1 of a WeatherGoose-II with v3.3 firmware; the use and operation of the SA-1 will be si

  • IT Watchdogs SA-1, 5 If you are using a Series-I unit: The alarm thresholds are the same as for series-II, but the method of setting them is somewhat different. Find the sensor block on the Alarms page for the Goose unit’s internal sensors, then set the threshold to 50 and the threshold to 110, as shown here, for the input which the SA-1 is connected to, then set the to the action you wish to take place when the trip threshold(s) are exceeded and click . (The input being used is highlighted here for example purposes.) Since the Analog input cannot go higher than 99, this wi

  • IT Watchdogs SA-1, 6 RD BK red wire goes into the terminal marked RD or (+) black wire goes into the terminal marked BK or (-) Ÿ Connecting the SA-1 to the CCAT-SMOKE: If you are using an ITWatchdogs monitoring device which does not have built-in analog inputs, such as the MiniGoose-II, or if you have already used up all of your analog inputs on other sensors, then you will need to attach the SA-1 via an appropriately-programmed CCAT analog-to-digital bus interface module, available from IT Watchdogs. The following diagrams show how to hook up and use an SA-1 in combination with a CCAT-SMOKE interface module. (Note: the CCAT has been manuf

  • IT Watchdogs SA-1, 7 NOTE: THERE IS A BUG IN SOME OLDER SERIES-II FIRMWARE VERSIONS WHICH CAUSES THE UNIT TO DISPLAY THE STATUS INCORRECTLY; i.e. the “Smoky” and “Clear” states are reversed! This does not affect the device’s actual operation or the ability to set alarm thresholds; it is merely a cosmetic issue with the “friendly” naming of the actual numeric values from the CCAT-SMOKE. However, it can be confusing, so if you find that your device is displaying the SA-1’s status opposite of what it should be, IT Watchdogs highly recommends updating

  • IT Watchdogs SA-1, 8 If you are using a Series-I unit: The alarm thresholds are the same as for series-II, but the method of setting them is somewhat different. Find the sensor block on the Alarms page for newly-connected CCAT-SMOKE, then set the threshold to 50 and the threshold to 110, as shown here, then set the to the action you wish to take place when the trip threshold(s) are exceeded and click . Since the reading on a CCAT analog-to-digital input channel cannot go higher than 99, this will effectively disable the High Trip event, which is not needed in this application. If you are using a Series-II unit: When you go to the Alarms page, you’ll find that a new parameter block has been add

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG W2363D Owner's manual lg/w2363d-479.pdf 15 Aug 2023 27
2 Kambrook KB815B Manual  kambrook/kb815b-O1N.pdf 14 Aug 2022 6
3 Philips SB5200 Operation & user’s manual philips/sb5200-2O8.pdf 18 May 2023 3
4 AquaVac TigerShark Owner's manual aquavac/tigershark-7C4.pdf 03 Mar 2023 20 0.94 Mb
5 RKC INSTRUMENT Z-TIO Host Communication Quick instruction manual rkc-instrument/z-tio-host-communication-337.pdf 09 May 2023 2 0.36 Mb
6 Moxa Technologies MIINEPORT E1 Operation & user’s manual moxa-technologies/miineport-e1-18A.pdf 17 Jun 2022 4

Similar Resources:

  • Rielta

    IPD-E Series

    (2 pages)
    4.1.1 The installation place of IPD-Ex must be in agreement with relevant requirements.4.1.2 The places for installation of the detectors must satisfy the following conditions:- exclude the possibility of moistening the detector with water and water ingress from the mounting surface side;- minimum vibration of structural units;- minimum lighting;- maximum di …
  • Firex

    AD

    (4 pages)
    lVROOMSMOKEALARMPLACEMENTClimate Controls Americas recommends complete coverage pro-tection achieved by installing asmokealarminevery roomofyourhome. The National Fire Protection Association's (NFPA) minimumrequirement, as stated in Standard 72, Chapter2,reads as follows:"2-2.1.1.1Smoke detectors shall beinstalled outside of each separate sleep-::: …
  • Honeywell

    SiXSHOCK

    (2 pages)
    SiXSHOCK Quick Installation Guide / Guide d'installation rapide Guía Rápida de Instalación / Guia rápido de instalação The SiXSHOCK is a 3-zone wireless shock/door/window sensor intended for use with Honeywell controls that support SiX™ series devices. It provides a reed switch/magnet zone, external wired contact zone, and built-in shock …
  • Dräger

    Polytron Pulsar 2

    (48 pages)
    WARNINGYou must read, understand, and comply with this TechnicalManual before you use the gas detector in order to ensurethe proper operation and function of the gas detector.!Dräger Polytron Pulsar 2Open Path Gas DetectorTechnical Manuali …
  • Abus

    RWM140

    (108 pages)
    RWM140User manualSmoke alarm deviceManuel utilisateurDispositif d'alarme de fumée GebruikershandleidingRookmelderIstruzioni per I'usoRilevatore di fumoBefolgen Sie die Anweisungen, um den ordnungsgemäßen Betrieb sicherzustellen. Rauchwarnmelder helfen Leben retten! Bewahren Sie diese Bedienungsanleitung sorgfältig auf.Bedienungs-, Installation …
  • LST

    55100-908

    (1 pages)
    © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVED55100-908_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.Manual Call Point55100-908Specifi cationsDescriptionThe Manual Call Point 55100-908 complies with t …

Comments, Questions and Opinions: