  • Gtec ZS110, 3 1 Introduction 1. 1 Description of Commonly Used Symbols Some or all of the following symbols may be used in this manual and may appear in your application process. Therefore, all users should read the form carefully and thoroughly. Symbol & Description Symbol Description Caution, danger Danger electric shock Alternating current (AC) Direct current (DC) Protective ground Recycle Do not dispose with ordinary trash 4 1. 2 Safety Instructions 1. Read this manual carefully and thoroughly before operation the UPS and save this

  • Gtec ZS110, 5 2 Product Description The ST-series is an on-line uninterruptible power supply device incorporating double-converter technology with single-phase input and single-phase output. It offers the high quality power supply with the greatest degree of availability and reliability. The 1-3kVA of ST series is compact and convenient for users, especially for the basic equipments in some areas such as: finance, communication, government, traffic, manufacture, education and so on. 2. 1 System Type and Configuration There are two types of UPS according to the battery configuration: standard type and long backup time type, e

  • 7 2. 3 Operating Principle Figure 2-4 The UPS operating principle 1. Input filter: it filters the input and provides clean AC power to the UPS. 2. AC/DC converter: In Normal mode, it converts the AC input power to regulated DC power, and raises the regulated DC voltage for DC/AC converter. 3. DC/DC converter: Raises the DC Voltage from the battery system to the opti

  • Gtec ZS110, 9 3 Installation 3. 1 Unpacking Inspection 1. Open the packing box of UPS and take it out, visually examine the unit for transit damage. 2. Check against the accessory lists that the accessories of the UPS are present. (Refer to Table 9-1). 3. Make sure the model is what you wanted from the nameplate on the rear panel 4. If the UPS arrives damaged, or there is any missing accessory or other question above, please contact the distributor immediately. 3. 2 Installation Notes 1. Wh

  • Gtec ZS110, 11 Figure 3-2 Connection method of output 3.3.2 Operation Procedure of External Battery for Long Backup Time UPS The battery connection procedure is very important for long backup model. Any incompliance may result in the risk of electric shock. Therefore, the following steps must be strictly complied with. 1. First connect in series the batteries of the pack to ensure proper battery voltage that ZS110-1KS for 36VDC, ZS110-2KS for 72VDC, ZS110-3KS for 96VDC. 2. Take out the battery cable delivered with the UPS, one end of the external battery cable is a plug for connecting

  • 13 Computer interface: The type of signals is provided by the UPS to communicate with a host computer through communication cable included in the standard accessory, User can use special monitor software UPSilon in the standard accessory to monitor the UPS through the port. 2. Alternative connection of communication Intelligent Slot: It is designed f

  • Gtec ZS110, 15 5 Operation (LCD model) 5.1 Operation Display Panel 1. ON button: Pressing the ON button more than 1 second (buzzer beeps once), the UPS system is turned on. 2. OFF button: By pressing this button more than 1 second (buzzer beeps once) turns off the UPS system whenever the UPS run under the normal mode/battery mode. 3. Function button The Function button provides the following functions: a) Battery self- diagnosis: When the UPS ran in normal mode, pressing this button more than 2 seconds (buzzer beeps twice) can start the battery self-diagnosis. b) Silence function in battery/bypass mode In battery/bypass

  • Gtec ZS110, 17 Figure 5-2 Normal Mode 2) If load is more than 100 percent, the buzzer beeps every second, meanwhile, the warning icon blinks every second too, reminding that UPS is overloaded. You should get rid of some unnecessary loads one by one to decrease the loads until the alarm clear 3) If the battery indicator blinks, it indicates that no battery is connected to the UPS or battery voltage is too low. You should check if battery is properly connected to the UPS, and press function button more than 2 seconds to start the battery self-diagnosis. If the connection between battery and UPS is confirmed

  • Gtec ZS110, 19 battery is not fully charged (the battery level icons lit one after another circularly). When the battery is fully charged, all the level icons are turned on. 1) When operating in bypass mode, the UPS beeps every 2 minutes. If the “Function” key is pressed for more than 2 seconds, the alarm will not beep (silence function). Press the “Function” key more than 2 seconds again to resume the alarm function. 2) If the utility power indicator blinks, it shows that the voltage or frequency of the utility power is out of the input range of the UPS or there are problems with revers

  • Gtec ZS110, 21 5.3 Operating Instructions 5.3.1 UPS ON/OFF Operation Note : The battery is fully charged before delivery. However, storage and transportation will inevitably cause some charge loss. Therefore, it is advisable to charge the battery for 10 hours before using it, so as to ensure adequate battery capacity. 1. Turning on the UPS The operation of turning on the UPS contains: turning on with utility power and turning on without utility power. 1) Turning on with utility power: Connect the mains input to the UPS, press the ON button more th

  • Gtec ZS110, 23 6 Maintenance 6.1 Battery Maintenance The battery is key component of the UPS. The battery life depends on the ambient temperature, charging and discharging times. High ambient temperature and deep discharging will shorten the battery life. 1. Sealed maintenance-free lead –acid battery be used in the standard. When being connected to the utility power whether the UPS has been turned on or not, the UPS keeps charging the battery and also offers the protective function of charging and discharging. 2. Keep the ambient temperature between 15℃ and 25℃ 3. If the UPS has not been used for a long period, charging

  • 25 7 Troubleshooting In the event of an UPS fault, shoot the trouble according to Table 6-1. If the fault still persists, please contact our customer service center. Faults Fault/Warning code Fault icon Alarm Possible cause Solution F01 on constantly Beep continuously Internal fault. Please contact the distributor or Service center F0

  • Gtec ZS110, 27 8 Specifications 8. 1 Electrical Model ZS11 0-1K ZS110- 1K-KS ZS11 0-2K ZS110- 2K-KS ZS11 0-3K ZS110- 3K-KS Rating 1KVA/800W 2KVA/1600W 3KVA/2400W Input system Single phase & earth ground Rated voltage 220VAC Voltage range 115VAC~300VAC Frequency 50Hz Power factor ≥0.99 Input Voltage range of bypass (80±5)VAC~(286±5)VAC Output system Single phase & earth ground Rated voltage 220VAC Power factor 0.8 Voltage precision ±2% Normal

  • Gtec ZS110, 29 9 Appendix 9.1 Consignment Lists Model Type Accessories No Machine 1 Intelligent monitor software CD 1 User Manual 1 Standard Model Serial communication cable 1 Machine 1 Intelligent monitor software CD 1 User Manual 1 External Battery Cable 1 Long backup time Model Serial communication cable 1

More Instructions:

DOWNLOAD

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Jonsered GT25 L Spare parts jonsered/gt25-l-15E.pdf 10 Jan 2024 5
2 TEC EXHAUST FAN FLOW METER Overview and manual tec/exhaust-fan-flow-meter-W59.pdf 09 Jan 2023 10
3 Paradyne 7986 Installation instructions manual paradyne/7986-BN2.pdf 13 Mar 2024 22 0.1 Mb
4 Western Digital WD SATA Hard Drives Quick install manual western-digital/wd-sata-hard-drives-1X1.pdf 07 Jan 2023 2 0.73 Mb
5 Sony DCR-TRV12E Operating instructions manual sony/dcr-trv12e-6VG.pdf 21 Aug 2022 320 6.59 Mb
6 Quantum Composers 9710 Series Specification quantum-composers/9710-series-Z46.pdf 04 Dec 2022 2 0.59 Mb

Similar Resources:

  • Online

    ZINTO Series

    (42 pages)
    INTRODUCTION 1 / 42 Z800-3000_usermanual_engl_updated_202001.docx User manual ONLINE ZINTO-series Models 800 – 3000 Germany Italy Switzerland ONLINE USV-Systeme AG Luise-Ullrich-Str. 8 D-82031 Grünwald Phone +49 (89) 2423990-10 Fax +49 (89) 2423990-20 www.online-usv.de ONLINE UPS-Systems S.r.l. Via Ferruccio Gilera 110 I-20862 Arco …
  • CyberPower

    PR750LCDRTXL2U

    (2 pages)
    The LCD display indicates a variety of UPS operational conditions. All descriptions apply when the UPS is plugged into the AC outlet and turned on or when the UPS is on battery. 10. Serial Port I Serial port allows connection and communication between the UPS and the computer. 11. Serial Port II Serial Port II relays information to equipm …
  • Tripp Lite

    SU1000XL

    (18 pages)
    200408112 93-22801111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comOwner’s Manual1111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comImportant Safety Instructions2Quick Installation3Basic Operation5Storage and Service11Specifications12SmartOnline™Intelligent, True …
  • Tripp Lite

    SMART1500LCDXL

    (6 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART1500LCDXLSmart LCD 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display, Expandable Runtime, USB &Serial ports Highlights1500VA / 1.5kVA 2U rack/tower 120V line interactive extended run UPSCorrects brownouts and overvolta …
  • PowerWalker

    VI 650 LCD/UK

    (8 pages)
    EN Line Interactive UPS PowerWalker VI 650 LCD/UK PowerWalker VI 850 LCD/UK PowerWalker VI 1000 LCD/UK PowerWalker VI 1500 LCD/UK PowerWalker VI 2000 LCD/UK Quick Start Guide …
  • Rackmount

    XVT-600

    (4 pages)
    Xtreme Power Conversion Corporation920 Bay Vista Blvd. • Englewood, Fl 34223 Tel: 800.582.4524 www.xpcc.comXVTXtreme Value Tower Series UPS’XVT-600 XVT-800 XVT-1200 XVT-1500CAPACITY 600VA/360W 800VA/480W 1200VA/720W 1500VA/900WINPUTPhase Single phaseVoltage Range 94V-144V/±5VFrequency 60HZ±5HzOUTPUTVoltage (battery mode) 120V±10%Waveform Pure Sine …

Comments, Questions and Opinions: