Brooktrout Technology IRAS-24A w/ T1-RBS Installation And Reference Manual
|
Brooktrout Technology IRAS-24A w/ T1-RBS, APPENDIX F Software License Agreement General Terms Brooktrout grants you a non-exclusive license to use the copies of the software program(s) supplied with this product on the following terms: You may: a. Use the software program on a computer or a network, but only in conjunction with a Brooktrout hardware product; b. Permit other individuals to have access to and use of the software program within or as part of a computer network, provided that the software is used solely in conjunction with a Brooktrout hardware product incorporated in a single server or a “host” computer environment, c. Make only those number of backup and
Installing the IRAS-24A Card 2-5 Connecting to the CSU After you physically install the IRAS-24A card, connect the T1 interface port to an external CSU. NOTE: If your card is the IRAS-24AC, skip to “Checking LEDs (Optional)” in the next section. The IRAS-24AC does not require an external CSU connection. To connect the IRAS-24A card to the CSU/T1 line: 1. Plug one end of the external
Brooktrout Technology IRAS-24A w/ T1-RBS, Installing the IRAS-24A Driver with Windows NT 4.0 3-21 You may choose to change the Legacy Name for the port. Data is the default traffic type. - Data: indicates that this port supports data only. This port can be used with RAS or by another application such as Procomm® or Hyperterm. Varied data types include: ISDN–64K/56K RBS–56K Modem–V.34/V.90/K56flex NOTE: If this port will be used with RAS, then it will not be available for use with any other application. Remote Access Service exclusively owns the port. Click OK to return to the Netaccess Devices screen. 3. After completing the configuration for all ports, choose OK to return to your computer desktop. You are now read
Brooktrout Technology IRAS-24A w/ T1-RBS, CHAPTER 3 Installing the IRAS-24A Driver with Windows NT 4.0 This chapter describes how to install the Netaccess device driver software under Windows NT 4.0. ❐ Installing the Netaccess IRAS-24A software - File copying - PCI auto-detection - Line configuration ❐ Adding Modems ❐ Installing RAS - Configuring RAS Ports - Setting up user permissions - Reboot ❐ Uninstalling the Netaccess IRAS-24A When you complete the procedures in this chapter, you can use the Netaccess IRAS-24A card with your PRI-ISDN or T
Brooktrout Technology IRAS-24A w/ T1-RBS, Service Provisioning A-17 ❐ Inverted HDLC Inverted HDLC “flips” the bits passing over the D-channel (turning ones to zeros and zeros to ones) to comply with the network’s restriction against sending eight zero bits in succession. Usually, inverted HDLC is enabled only on older network lines that use D4 Superframe (SF) framing, so the default value is disabled. NOTE: If the service provider has trouble answering this question, ask the provider what type of framing and line coding will be used on the PRI line. If the answer is Extended Superframe (ESF) framing and B8ZS line coding, disable inverted HDLC. ❐ Automatic rate adaption Rate adaption allows
Brooktrout Technology IRAS-24A w/ T1-RBS, Basic Operations and Troubleshooting 5-7 Figure 5-2 Windows NT Diagnostics – Resources Screen 3. Select the I/O Ports button to view the I/O Port Addresses assigned to system devices. 4. Select the Memory button to view the Memory Addresses assigned to system devices. 5. Select the Devices button to view devices (Figure 5-3) assigned to the system. 6. Look for any NetaccPC entries. To view NetaccPC properties, double-click the NetaccPC entry.
Brooktrout Technology IRAS-24A w/ T1-RBS, 3-32 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide 10. When you complete your selections, click OK. NOTE: If you are not sure which protocols to choose, refer to the Windows NT Server documentation, or click Help. 11. When the Remote Access Setup window is redisplayed, click Continue. Windows NT Setup posts an informational message to let you know that it is configuring the RAS ports. 12. At the Setup Message screen, click OK. 13. When the Network dialog box is displayed, click Close . Window
Brooktrout Technology IRAS-24A w/ T1-RBS, Index-7 uninterruptible power supply A-8 Unknown number type 3-14, 4-14 Unknown numbering plan 3-13, 4-13 unpacking the card 2-2 User Side signaling 3-14, 4-14, A-17 utilities 3-40, 4-40 V variants determing value to enter A-16 Windows NT 3-13, 4-13 W wall jack A-9, A-10, A-12 warranty information D-1 Windows NT 1-1, 1 checking the Event Log 16 error entries 9 features vi operational checklist 1 permissions 3-39, 4-38 server settings 3-30, 4-30 setup 4-32 system log
Brooktrout Technology IRAS-24A w/ T1-RBS, 3-38 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide To remove all Netaccess Comport Software from your system: 1. From the taskbar, select Start → Settings → Control Panel → Add/Remove Programs 2. Select Netaccess Comport from the list of installed software and click on the Add/Remove button. NOTE: To ensure deletion of the Netaccess icon from the Control Panel, the Control Panel must be closed. Close the Control Panel (keeping the Add/Remove Programs Properties screen open), before clicking on Add/Remove. Netaccess folders and all files that are installed on your system are deleted. 3. Reboot your system so that the changes to the netwo
Brooktrout Technology IRAS-24A w/ T1-RBS, APPENDIX E Agency Warnings and Notices FCC Rules and Regulations - Part 15 The Netaccess IRAS-24A Card complies with FCC Rules for a Class A digital device. As required by FCC Rules and Regulations, the following information is provided for the guidance of the user. This equipment has been tested and found to comply with the limits for Class A digital devices pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
Brooktrout Technology IRAS-24A w/ T1-RBS, Installing the IRAS-24A Driver with Windows NT 4.0 3-3 T1 Provisioning ❐ You should have completed provisioning for PRI-ISDN service, or T1-RBS service (see Appendix A). Be sure to complete the “ISDN Provisioning Worksheet” (Figure A-2 in Appendix A or the last page of this book) or the “T1-RBS Provisioning Worksheet” (Figure A-3 in Appendix A or the last page of this book) with the required information when ordering your service. Network ❐ A LAN network card other than the IRAS-24A has been installed and configured. If there is no network adapter i
C-8 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide Diagnostics for Windows NT 3.51 After the IRAS adapter card and driver software are installed and running on your system, the VTTY port can be opened. NOTE: If you have not installed the driver software, please refer to the installation instructions for Windows NT 3.51 in Chapter 4 of this document. To run the Anycall
Basic Operations and Troubleshooting 5-3 ❐ Remote users cannot connect; their calls are immediately rejected. Possible problems are: - Server is not operating properly (refer to checklist in the previous section). - Line has been “busied out” by the service provider. Check the status indicators on the CSU. - IRAS-24A card is not configured properly. Verify
Brooktrout Technology IRAS-24A w/ T1-RBS, Basic Operations and Troubleshooting 5-17 The Control box (not displayed) provides driver version information and can also be used to launch individual line status windows for up to 4 cards. Figure 5-11 Line Status for PRI-ISDN Configuration Figure 5-12 Line Status for T1-RBS Configuration
Brooktrout Technology IRAS-24A w/ T1-RBS, 5-10 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide Running the Netaccess Status Utility The Netaccess Line Status Tool utility enables you to check the alarm and D-channel status of the T1 line connected to the IRAS-24A card. Phone calls can only be made/received when a line has both: ❐ The D-channel established (ISDN only) ❐ The PRI-ISDN or T1-RBS line is not in alarm Figure 5-5 Path to the Netaccess Status Utility To run the Netaccess Status Utility (Figure 5-5): 1. From the taskbar, select Start →Programs → Netaccess→Iras-24a →Line Status Tool
Brooktrout Technology IRAS-24A w/ T1-RBS, 1-2 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide ❐ An external Channel Service Unit (CSU) device to connect the T1 line to the IRAS-24A card, or the optional internal CSU device installed on the card itself; see Chapter 2 and Appendix A. Hardware and Software Requirements This section discusses additional hardware requirements specific to your server and network operating system. Hardware for Windows NT To use the IRAS-24A card, your PC must meet the system requirements for Windows NT Server, Version
Brooktrout Technology IRAS-24A w/ T1-RBS, Installing the IRAS-24A Driver with Windows NT 3.51 4-17 NOTE: When installing the IRAS-24A with an external CSU, the Line Length/Build Out must be set to a length (ft.) that most closely corresponds to the distance between the adapter card and the external CSU. For the IRAS-24AC with an internal CSU option, set the Line Length/Build Out starting at -0.0db. 3. When you have entered the appropriate information for all fields, choose OK to return to the Netaccess Devices screen. Continue with the section “Configuring Ports” on page 4-19.
Abocom USB Home PhoneLine 1Mbps Network Adapter Network Card Operation & user’s manual
USB Home PhoneLine 1Mbps Network Adapter |
D-Link Air DWL-120 Network Card Manual
Air DWL-120 |
Fluke NetTool Network Card Quick reference manual
NetTool |
Cabletron Systems DLE52-MA Network Card Operation & user’s manual
DLE52-MA |
NETGEAR GA621 Network Card Brochure & specs
GA621 |
Delta Electronics SIR106 Network Card Specification sheet
SIR106 |
Crestron TPS-IMC-BV Network Card Operation manual
TPS-IMC-BV |
Dell PowerVault 220S Network Card Setup and quick reference manual
PowerVault 220S |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Hawking | Net-Talk HNT1A | Quick installation manual | hawking/net-talk-hnt1a-DY7.pdf | 12 Oct 2022 | 16 | 1.17 Mb |
2 | Electrolux | ER 7628 B | Instruction book | electrolux/er-7628-b-ACE.pdf | 23 Nov 2023 | 24 | 0.37 Mb |
3 | Lenovo | Z60T | Setup manual | lenovo/z60t-591.pdf | 13 May 2023 | 2 | |
4 | Kleenmaid | LEK37A | Installation manual | kleenmaid/lek37a-43S.pdf | 28 Mar 2023 | 32 | |
5 | Aquatic | AQ-PSB-1 | Owner's manual | aquatic/aq-psb-1-19E.pdf | 13 Jun 2023 | 7 | |
6 | JVC | AV-14AG16, AV-14FMG6B, AV-21BM | Instructions manual | jvc/av-14ag16-av-14fmg6b-av-21bm-YC3.pdf | 12 Oct 2022 | 20 |
NETGEAR
Aer the satellite is powered on, the satellite’s ring LED lights white while the satellite attempts to sync with the router, lights one of the following colors for about three minutes, and then turns o:Quick Start GuideBlueThe connection between the router and satellite is good.AmberThe connection between the router and satellite is fair. Consider mo …
Orbi RBR40(2 pages) |
Arbor Technology
- 1 -Quick Installation GuideVersion 1.0Power-over-Ethernet Interface CardsPoE-i211 & i214Form Factor Ethernet Controller PoE PSE ControllerPCI Express® x1 Intel® Ethernet Controller i210ITLinear Tech LTC4266C♦ Technical SupportIf you have any technical difculties, please consult the user’s manual rst at: ftp://ftp.arbor.com.tw/ …
PoE-i211(8 pages) |
Viking
Remote Control of:• Secure building entry• Heating/cooling equipment• Pumps and fans• Security system• Gates• Lighting• Emergency tonesRC-4RC-4Network EnabledRelay ControllerSeptember 19, 2012The RC-4 Network Enabled Relay Controllerprovides networked control of four remoterelays via a web interface. The same interfacecan be used to ch …
RC-4(12 pages) |
National Instruments
CALIBRATION PROCEDURENI 92194-Channel, 24-Bit, Universal Analog Input ModuleThis document contains information for calibrating the NI 9219. For more information on calibration, visit ni.com/calibration.ContentsSoftware.................................................................................................................................... 2Document …
NI 9219(40 pages) |
CH Tech
C&H Technologies, Inc. • 445 Round Rock West Drive • Round Rock, TX 78681-5012(512) 733-2621 • FAX (512) 733-2629 • www.chtech.com Ordering InformationDescriptionAM105 M-Module Extender BoardPart NumberAM105 11028421-0001AM105 M-Module Extender Board:The M-Mod u le Ex te nder bo ard eases the M-Mo dul edev elop me n t cycle …
AM105(1 pages) |
NETGEAR
)NSTALLATION'UIDERangeMax™ WPN111 Wireless USB 2.0 AdapterThese basic setup instructions assume that you will connect to an access point, and you are not using WEP security. Please refer to the online help and the Reference Manual on your CD for instructions on configuring WEP, Ad-hoc mode, or advanced options.Estimated Completion Time: 5-15 minute …
WPN111(2 pages) |
Hayter Lawn Mower Harrier 48 BBCHayter Harrier 48 BBC User Guide (Owner's handbook manual), @8B2B29 Harrier 48 BBC, 36 |
Abocom Headsets BCH110Abocom BCH110 Manual (Doc Type: Headsets Quick installation manual) BCH110, 2 |
Atlona Amplifier AT-VID18Atlona Amplifier Operation & user’s manual (File: atlona-at-vid18-amplifier-8, Thu 12.2023) AT-VID18, 8 |
Ricoh Printer Aficio SG 3110DNRicoh Aficio SG 3110DN Manual (Doc Type: Printer Installation manual) Aficio SG 3110DN, 18 |
Acura Automobile 2012 ZDXAcura 2012 ZDX User Manual (Owner's manual), @R5FSQO 2012 ZDX, 370 |
BFT Gate Opener ARESInstallation and user manual for BFT ARES Gate Opener ARES, 13 |
Pulsar Portable Generator PG2000iSPulsar Portable Generator PG2000iS Operator's manual PG2000iS, 30 |
LENCO Portable Stereo System SCD-2000 BTLENCO Product Manual: SCD-2000 BT PDF Operation & user’s manual - 2947FE SCD-2000 BT, 28 |
Toshiba Portable DVD Player SD-P1700SNToshiba Portable DVD Player SD-P1700SN Owner's manual SD-P1700SN, 72 |
KUSSMAUL Other 091-27Instruction manual for KUSSMAUL 091-27 Other 091-27, 5 |
BENSON HEATING LTD Heater LD7 1LPPDF Manual (@FC7UBF), BENSON HEATING LTD LD7 1LP Heater (22.11.2023) LD7 1LP, 23 |
Marantz Receiver NR1402Getting started manual for Marantz NR1402 Receiver NR1402, 16 |