Manualios.com

Brooktrout Technology IRAS-24A w/ T1-RBS Installation And Reference Manual

  • IRAS-24A w/ T1-RBS Network Card
  • maTp9bkNp6zUs
  • Installation And Reference Manual
  • PDF / Adobe Acrobat Reader
  • 188

Brooktrout Technology IRAS-24A w/ T1-RBS Manual Online:

4.45, 2570 votes
Brooktrout Technology IRAS-24A w/ T1-RBS User Manual
Brooktrout Technology IRAS-24A w/ T1-RBS User Guide
Brooktrout Technology IRAS-24A w/ T1-RBS Online Manual

Text of Brooktrout Technology IRAS-24A w/ T1-RBS User Guide:

  • Brooktrout Technology IRAS-24A w/ T1-RBS, APPENDIX F Software License Agreement General Terms Brooktrout grants you a non-exclusive license to use the copies of the software program(s) supplied with this product on the following terms: You may: a. Use the software program on a computer or a network, but only in conjunction with a Brooktrout hardware product; b. Permit other individuals to have access to and use of the software program within or as part of a computer network, provided that the software is used solely in conjunction with a Brooktrout hardware product incorporated in a single server or a “host” computer environment, c. Make only those number of backup and

  • Installing the IRAS-24A Card 2-5 Connecting to the CSU After you physically install the IRAS-24A card, connect the T1 interface port to an external CSU. NOTE: If your card is the IRAS-24AC, skip to “Checking LEDs (Optional)” in the next section. The IRAS-24AC does not require an external CSU connection. To connect the IRAS-24A card to the CSU/T1 line: 1. Plug one end of the external

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Installing the IRAS-24A Driver with Windows NT 4.0 3-21 You may choose to change the Legacy Name for the port. Data is the default traffic type. - Data: indicates that this port supports data only. This port can be used with RAS or by another application such as Procomm® or Hyperterm. Varied data types include: ISDN–64K/56K RBS–56K Modem–V.34/V.90/K56flex NOTE: If this port will be used with RAS, then it will not be available for use with any other application. Remote Access Service exclusively owns the port. Click OK to return to the Netaccess Devices screen. 3. After completing the configuration for all ports, choose OK to return to your computer desktop. You are now read

  • Brooktrout Technology IRAS-24A w/ T1-RBS, CHAPTER 3 Installing the IRAS-24A Driver with Windows NT 4.0 This chapter describes how to install the Netaccess device driver software under Windows NT 4.0. ❐ Installing the Netaccess IRAS-24A software - File copying - PCI auto-detection - Line configuration ❐ Adding Modems ❐ Installing RAS - Configuring RAS Ports - Setting up user permissions - Reboot ❐ Uninstalling the Netaccess IRAS-24A When you complete the procedures in this chapter, you can use the Netaccess IRAS-24A card with your PRI-ISDN or T

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Service Provisioning A-17 ❐ Inverted HDLC  Inverted HDLC “flips” the bits passing over the D-channel (turning ones to zeros and zeros to ones) to comply with the network’s restriction against sending eight zero bits in succession. Usually, inverted HDLC is enabled only on older network lines that use D4 Superframe (SF) framing, so the default value is disabled. NOTE: If the service provider has trouble answering this question, ask the provider what type of framing and line coding will be used on the PRI line. If the answer is Extended Superframe (ESF) framing and B8ZS line coding, disable inverted HDLC. ❐ Automatic rate adaption  Rate adaption allows

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Basic Operations and Troubleshooting 5-7 Figure 5-2 Windows NT Diagnostics – Resources Screen 3. Select the I/O Ports button to view the I/O Port Addresses assigned to system devices. 4. Select the Memory button to view the Memory Addresses assigned to system devices. 5. Select the Devices button to view devices (Figure 5-3) assigned to the system. 6. Look for any NetaccPC entries. To view NetaccPC properties, double-click the NetaccPC entry.

  • Brooktrout Technology IRAS-24A w/ T1-RBS, 3-32 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide 10. When you complete your selections, click OK. NOTE: If you are not sure which protocols to choose, refer to the Windows NT Server documentation, or click Help. 11. When the Remote Access Setup window is redisplayed, click Continue. Windows NT Setup posts an informational message to let you know that it is configuring the RAS ports. 12. At the Setup Message screen, click OK. 13. When the Network dialog box is displayed, click Close . Window

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Index-7 uninterruptible power supply A-8 Unknown number type 3-14, 4-14 Unknown numbering plan 3-13, 4-13 unpacking the card 2-2 User Side signaling 3-14, 4-14, A-17 utilities 3-40, 4-40 V variants determing value to enter A-16 Windows NT 3-13, 4-13 W wall jack A-9, A-10, A-12 warranty information D-1 Windows NT 1-1, 1 checking the Event Log 16 error entries 9 features vi operational checklist 1 permissions 3-39, 4-38 server settings 3-30, 4-30 setup 4-32 system log

  • Brooktrout Technology IRAS-24A w/ T1-RBS, 3-38 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide To remove all Netaccess Comport Software from your system: 1. From the taskbar, select Start → Settings → Control Panel → Add/Remove Programs 2. Select Netaccess Comport from the list of installed software and click on the Add/Remove button. NOTE: To ensure deletion of the Netaccess icon from the Control Panel, the Control Panel must be closed. Close the Control Panel (keeping the Add/Remove Programs Properties screen open), before clicking on Add/Remove. Netaccess folders and all files that are installed on your system are deleted. 3. Reboot your system so that the changes to the netwo

  • Brooktrout Technology IRAS-24A w/ T1-RBS, APPENDIX E Agency Warnings and Notices FCC Rules and Regulations - Part 15 The Netaccess IRAS-24A Card complies with FCC Rules for a Class A digital device. As required by FCC Rules and Regulations, the following information is provided for the guidance of the user. This equipment has been tested and found to comply with the limits for Class A digital devices pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Installing the IRAS-24A Driver with Windows NT 4.0 3-3 T1 Provisioning ❐ You should have completed provisioning for PRI-ISDN service, or T1-RBS service (see Appendix A). Be sure to complete the “ISDN Provisioning Worksheet” (Figure A-2 in Appendix A or the last page of this book) or the “T1-RBS Provisioning Worksheet” (Figure A-3 in Appendix A or the last page of this book) with the required information when ordering your service. Network ❐ A LAN network card other than the IRAS-24A has been installed and configured. If there is no network adapter i

  • C-8 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide Diagnostics for Windows NT 3.51 After the IRAS adapter card and driver software are installed and running on your system, the VTTY port can be opened. NOTE: If you have not installed the driver software, please refer to the installation instructions for Windows NT 3.51 in Chapter 4 of this document. To run the Anycall

  • Basic Operations and Troubleshooting 5-3 ❐ Remote users cannot connect; their calls are immediately rejected. Possible problems are: - Server is not operating properly (refer to checklist in the previous section). - Line has been “busied out” by the service provider. Check the status indicators on the CSU. - IRAS-24A card is not configured properly. Verify

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Basic Operations and Troubleshooting 5-17 The Control box (not displayed) provides driver version information and can also be used to launch individual line status windows for up to 4 cards. Figure 5-11 Line Status for PRI-ISDN Configuration Figure 5-12 Line Status for T1-RBS Configuration

  • Brooktrout Technology IRAS-24A w/ T1-RBS, 5-10 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide Running the Netaccess Status Utility The Netaccess Line Status Tool utility enables you to check the alarm and D-channel status of the T1 line connected to the IRAS-24A card. Phone calls can only be made/received when a line has both: ❐ The D-channel established (ISDN only) ❐ The PRI-ISDN or T1-RBS line is not in alarm Figure 5-5 Path to the Netaccess Status Utility To run the Netaccess Status Utility (Figure 5-5): 1. From the taskbar, select Start →Programs → Netaccess→Iras-24a →Line Status Tool

  • Brooktrout Technology IRAS-24A w/ T1-RBS, 1-2 IRAS-24A T1/ISDN Modem Card Installation and Reference Guide ❐ An external Channel Service Unit (CSU) device to connect the T1 line to the IRAS-24A card, or the optional internal CSU device installed on the card itself; see Chapter 2 and Appendix A. Hardware and Software Requirements This section discusses additional hardware requirements specific to your server and network operating system. Hardware for Windows NT To use the IRAS-24A card, your PC must meet the system requirements for Windows NT Server, Version

  • Brooktrout Technology IRAS-24A w/ T1-RBS, Installing the IRAS-24A Driver with Windows NT 3.51 4-17 NOTE: When installing the IRAS-24A with an external CSU, the Line Length/Build Out must be set to a length (ft.) that most closely corresponds to the distance between the adapter card and the external CSU. For the IRAS-24AC with an internal CSU option, set the Line Length/Build Out starting at -0.0db. 3. When you have entered the appropriate information for all fields, choose OK to return to the Netaccess Devices screen. Continue with the section “Configuring Ports” on page 4-19.

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Hawking Net-Talk HNT1A Quick installation manual hawking/net-talk-hnt1a-DY7.pdf 12 Oct 2022 16 1.17 Mb
2 Electrolux ER 7628 B Instruction book electrolux/er-7628-b-ACE.pdf 23 Nov 2023 24 0.37 Mb
3 Lenovo Z60T Setup manual lenovo/z60t-591.pdf 13 May 2023 2
4 Kleenmaid LEK37A Installation manual kleenmaid/lek37a-43S.pdf 28 Mar 2023 32
5 Aquatic AQ-PSB-1 Owner's manual aquatic/aq-psb-1-19E.pdf 13 Jun 2023 7
6 JVC AV-14AG16, AV-14FMG6B, AV-21BM Instructions manual jvc/av-14ag16-av-14fmg6b-av-21bm-YC3.pdf 12 Oct 2022 20

Similar Resources:

  • NETGEAR

    Orbi RBR40

    (2 pages)
    Aer the satellite is powered on, the satellite’s ring LED lights white while the satellite attempts to sync with the router, lights one of the following colors for about three minutes, and then turns o:Quick Start GuideBlueThe connection between the router and satellite is good.AmberThe connection between the router and satellite is fair. Consider mo …
  • Arbor Technology

    PoE-i211

    (8 pages)
    - 1 -Quick Installation GuideVersion 1.0Power-over-Ethernet Interface CardsPoE-i211 & i214Form Factor Ethernet Controller PoE PSE ControllerPCI Express® x1 Intel® Ethernet Controller i210ITLinear Tech LTC4266C♦ Technical SupportIf you have any technical difculties, please consult the user’s manual rst at: ftp://ftp.arbor.com.tw/ …
  • Viking

    RC-4

    (12 pages)
    Remote Control of:• Secure building entry• Heating/cooling equipment• Pumps and fans• Security system• Gates• Lighting• Emergency tonesRC-4RC-4Network EnabledRelay ControllerSeptember 19, 2012The RC-4 Network Enabled Relay Controllerprovides networked control of four remoterelays via a web interface. The same interfacecan be used to ch …
  • National Instruments

    NI 9219

    (40 pages)
    CALIBRATION PROCEDURENI 92194-Channel, 24-Bit, Universal Analog Input ModuleThis document contains information for calibrating the NI 9219. For more information on calibration, visit ni.com/calibration.ContentsSoftware.................................................................................................................................... 2Document …
  • CH Tech

    AM105

    (1 pages)
    C&H Technologies, Inc. • 445 Round Rock West Drive • Round Rock, TX 78681-5012(512) 733-2621 • FAX (512) 733-2629 • www.chtech.com Ordering InformationDescriptionAM105 M-Module Extender BoardPart NumberAM105 11028421-0001AM105 M-Module Extender Board:The M-Mod u le Ex te nder bo ard eases the M-Mo dul edev elop me n t cycle …
  • NETGEAR

    WPN111

    (2 pages)
    )NSTALLATION'UIDERangeMax™ WPN111 Wireless USB 2.0 AdapterThese basic setup instructions assume that you will connect to an access point, and you are not using WEP security. Please refer to the online help and the Reference Manual on your CD for instructions on configuring WEP, Ad-hoc mode, or advanced options.Estimated Completion Time: 5-15 minute …

Comments, Questions and Opinions: