  • Broseley Hercules 12, Hercules Boiler Model 4 Additional Air A permanent air entry opening or openings with a total free area of at least 550mm 2 per Kw of appliance rated output above 5Kw. If a flue draught stabiliser is used, extra ventilation will be required. There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room. Hearth And Clearances Your stove must be installed on a solid, level non-combustible hearth and with a gap of at least 600mm from any combustible material such as beams or skirting. The hearth protrusion in front of th

  • Broseley Hercules 12, Hercules Boiler Model 14 The tertiary air control The tertiary air control, or afterburner control, is used to burn the smoky fumes and volatile gasses that would normally be lost up the chimney. Because of the lack of oxygen within these gasses, they would not burn any more. When the tertiary air control is used, additional heat will be generated. Using this control helps prevent excessive creosote formation and smoke pollution, it also makes the fire burn at a more efficient rate as extra heat is generated when using this control. Tertiary Air Control Figure 3 – Tertiary Air Control Curing the Stove

  • Broseley Hercules 12, Hercules Boiler Model 18 WARNING NOTE Properly installed, operated and maintained this appliance will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, the following immediate actions should be taken:- a) Open doors and windows to ventilate the room. b) Let the fire out or eject and safely dispose of fuel from the appliance. c) Check for flue or chimney blockage and clean

  • Broseley Hercules 12, Hercules Boiler Model 3 INSTALLATION OF STOVE These instructions cover the basic principles to ensure the satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove. It should be noted that the Building Regulations requirements may be me

  • Broseley Hercules 12, Hercules Boiler Model 10 Fit the Front Plate Offer the vertically recessed rope seals to the leading edges of the Boiler Unit (the top edge of the Top Plate should be about 50mm above the top edge of the Boiler Unit) and allow the Front Plate to slide down until the catches engage with the pins located on the Boiler Unit. To ensure that the Front Plate has been securely located place a woodblock on the top edge of the Front Plate and apply a sharp tap with a lump hammer to the woodblock. WARNING !!! DO NOT HIT THE

  • Broseley Hercules 12, He r R E r cules Boil e I T T HIS AP P QUALIFI E AD AN D INSTR U e r Model 1 I nstall a Hercul ested to E P LIANCE M ED ENGIN D FOLL O U CTIO N requir e a tion a n es 12, Mul t N 13240 UST BE I N EER. DIY I TH O W THE N S FULL Y e ments m n d Op e 20, 30 t i Fuel S N STALLED A I NSTALLA T H E GUAR A INSTAL Y . Failur e m a y v oi d e ration Boiler M S tove A ND COM M T IONS A R E A NTEE LATION e to co m d the

  • Broseley Hercules 12, Hercules Boiler Model 12 OPERATION OF STOVE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THE STOVE It is very important not to leave the stove running with the doors open. This allows far too much air into the stove causing the fire to burn excessively hot and will severely damage the stove. MAINTAINANCE REQUIREMENTS The product you have purchased is a working appliance. It is important that routine maintenance is carried out to ensure its longevity. Rope seals on doors and glass should be checked on installation to ensure a good seal. Place a strip of paper in the door and close

  • He r Fig u Th e ac h ma y If f mi n Ho r be c A v a chi m sp e r cules Boil e u re 1 – Su m e chimney h ieve suffi c y be requi lued from n imum of 6 r izontal s e c ome bloc k a riety of c m ney. If y e cialist to f e r Model 6 S m mary of fl u should b e c ient dra w r

  • Broseley Hercules 12, Hercules Boiler Model 23 ANNUAL SERVICE RECORD INSTALLATION DATE OF APPLIANCE: 1ST YEAR SERVICE completion date: SERVICE ENGINEER: . REG. No. COMPANY NAME: . COMPANY ADDRESS: . POSTCODE: CONTACT NUMBER 2ND YEAR SERVICE completion date: SERVICE ENGINEER: . . REG. No. COMPANY NAME: . COMPANY ADDRESS: . POSTCODE: 3RD YEAR SERVICE completion date: SERVICE ENGINEER: . . REG. No. COMPANY NAME: . COMPANY AD

  • Broseley Hercules 12, Hercules Boiler Model 19 Trouble-Shooting 1. Smoke comes out of the stove when the loading door is opened. • The chimney cavity into which the flue pipe has been installed may be less than the minimum requirement. • Deposits (soot) may have built up in the chimney and be restricting the flow of waste products. This flow rate is known as the ‘draw’. 2. The Stove does not produce the expected heat into the room. • Has the flue pipe been sealed to the chimney to

  • Broseley Hercules 12, Hercules Boiler Model 24 LIMITED WARRANTY This appliance must be installed and commissioned by a fully qualified, registered engineer. A “Declaration of completion Certificate” must be obtained for the installation and retained by the end user. Failure to comply with these requirements may void your warranty. You, as the end user, have a contract by law with the supplier / dealer from whom you purchased the product. That dealer then has the same contract with the manufacturer or wholesaler and these have a contract with their suppliers. ALL CLAIMS MUST FOLLOW THIS PROCEDURE . Thank you

  • Broseley Hercules 12, Hercules Boiler Model 8 Connection to Chimney Flue A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. It is important that the connection between the stove spigot and the flue pipe is effectively sealed with heat resistant fire cement and/ or glass fibre rope to prevent harmful gases leaking into the room. The diameter of the flue spigot (pre fibre roped) provided with the stove is 8” (200mm) and can only be fitted to the top of the stove and must be tightly fi

  • Hercules Boiler Model 11 Commission/Handover Ensure loose parts are fitted in accordance with the instructions for “Assembly” given above. On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and emitted safely t

  • Hercules Boiler Model 15 Permanent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. In accordance with current Building Regulations the installer should have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air. This air vent shou

  • Hercules Boiler Model 2 HERCULES MULTIFUEL SAFETY BOILER STOVE INSTALLATION AND OPERATION MANUAL Thank You May we take this opportunity to thank you for choosing a Hercules, cast iron Multi-fuel Boiler stove. Please take time to read this manual and follow the guidelines on how to install and operate your new stove, as we feel sure it will enable you t

  • Broseley Hercules 12, Hercules Boiler Model 13 Ash Pan The ash pans can be removed using the double end of the poker which fits under the top lip of the ash pan. Care must be exercised when opening the doors as the handle and this part of the stove will be very hot. Use the glove provided. Do not put hot ashes into anything other than a metal container unless you know the ashes are cold. Ash pan removal is best done when either the contents of the ash pan have cooled or the stove is out, as some red hot coals can be covered by the ash

  • Broseley Hercules 12, Hercules Boiler Model 9 Boiler Connections All boiler models are fitted with 4 connections for piping. These connections are 1 ½ Inch BSP and are a female thread. It is possible to only use 2 of these connections, however opposite angles must be used – For example Flow top right, return bottom left. The 2 excess connections can then be capped off. Checks on Initial Firing Before connecting up the boiler the installer must ensure that they thoroughly flush all of the systems pipes i

  • Broseley Hercules 12, Hercules Boiler Model 5 Chimney This appliance must not be fitted into a chimney serving another heating appliance. It is most important that there is no obstruction in the flue or chimney. Please ensure that any existing chimney is clear of obstruction and swept clean immediately before installation of the stove. If the chimney has been used for an open fire it is recommended that it be swept for a second time having been used for a month following installation. As a closed appliance operates at a higher flue temperature, it

  • Broseley Hercules 12, Hercules Boiler Model 17 Burning Solid Fuel Solid fuel needs a flow of air for combustion though the bottom of the grate. Wood does not require this and will readily burn on a bed of ash with a flow of air over the top. Use the single end of the poker provided to push the ash and debris through the grate before refuelling. This will allow the passage of air and prevent the grate from clogging. Make sure there is sufficient hot fuel left to allow the fire to pick up once refuelling has occurred. This will look like a level, shallow bed of hot embers with no spaces. After prolo

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GE ASQ08FL Dimensions and installation information ge/asq08fl-G1Z.pdf 01 Mar 2024 2 0.16 Mb
2 Caretec Wooffy Operation & user’s manual caretec/wooffy-299.pdf 20 Sep 2023 8
3 Philips 32PT5441/37 Operation & user’s manual philips/32pt5441-37-3TB.pdf 09 Oct 2022 42 2.03 Mb
4 Philips MCM196D Specifications philips/mcm196d-119.pdf 16 Aug 2023 2 0.42 Mb
5 Philips HX3351 Specification sheet philips/hx3351-CL2.pdf 22 Jun 2023 2 0.22 Mb
6 Singer 71-53 Parts list singer/71-53-A6C.pdf 08 Jul 2023 48

Similar Resources:

  • EnergyLogic

    EL-200B

    (99 pages)
    Item # 98030034 Issue date: 26 March 2014 Installation & Operation Manual EL-200B, EL-375B, and EL-500B 115V/60Hz ASME Certified Designed to save. Built to last. ™ …
  • Coopra

    40C

    (32 pages)
    EN Installation Manual Heating Boiler . . . Type 40C Wall hung, fan flue, room sealed gas boiler CHAPTER 1. GENERAL CHAPTER 2. INSTALLATION CHAPTER 3. SUSPENDING THE UNIT CHAPTER 4. COMMISSIONING CHAPTER 5. TEMPERATURE REGULATIONS CHAPTER 6. BURNER STATES and MONITORING CHAPTER 7. MAINTENANCE CHAPTER 8. MALF …
  • Aerco

    Modulex 303

    (60 pages)
    Instruction No. GF-115H AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA Installation, Operation & Maintenance Instructions Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060 Printed in U.S.A. 7/ …
  • Hamworthy

    PUREWELL VariHeat c

    (2 pages)
    1 Hamworthy Heating Limited Purewell Variheat 500001168/B PUREWELL VariHeat (c & he Models) INSTRUCTIONS FOR USE Note:- This boiler is for use on Natural Gas (2nd Family) I2H only. Only a competent person must carry out any adjustments. WARNING: All installations MU …
  • Baxi

    Duo-tec Combi 24 HE A

    (60 pages)
    © Baxi Heating UK Ltd 2009Platinum Combi HE A RangeGas Fired Wall Mounted CondensingCombination BoilerInstallation & Servicing InstructionsThese instructions include the Benchmark Commissioning Checklist and should be left with the user for safe keeping. …
  • Columbia

    CSFH-3 WATER

    (32 pages)
    P/N 27512601, Rev. A [01/09]OIL FIRED CAST IRON BOILERINSTALLATION, OPERATION & MAINTENANCE MANUALCo l u m b i a bo i l e r Co m p a n yMain ofces and Factory: Pottstown, PA …