  • Atlantic VF 40, ADDRESS: ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR WEB: WWW.ATLANTICBOILERS.COM EMAIL: [email protected] TEL: 0161 621 5960 FAX: 0161 621 5966 VF Model USE & MAINTENANCE WALL-MOUNTED GAS CONDENSING BOILER 40, 60, 80 & 100KW OUTPUT MODULATING BURNERS After sales service is guaranteed by Atlantic Boilers The boilers conform to the following CE Directives Directive 2006/95/CD - low voltage Directive 2004/108/CEE - electromagnetic compatibility Directive 92/42/CEE - efficiency Directive 90/396/CEE

  • Atlantic VF 40, Summary 1. General characteristics .........................................................................................................3 1.1. Acceptable gas pressure .................................................................................................................3 1.2. Combustion conditions .....................................................................................................................3 1.3. Operating conditions .......................................................................................................

  • Atlantic VF 40, page 3/17 1. General Characteristics The V F boiler is set in the Factory to operate on Natural Gas Group H with a supply pressure of 20mBar. F or higher gas pressure up to 300mBar, a filter and a pressure regulator must precede the V F gas valve. 1.1. Acceptable gas pressure Gaz naturel H G20 Nominal (mbar) 20 Minimum (mbar) 17 Maximum (mbar) 25 1.2. Combustion conditions VF 40 60 80 100 Nominal output Pn (80/60°C) kW 56,5 92,6 Nominal condensing output P (50/30°C) kW 61,8 10

  • Atlantic VF 40, page 4/17 1.3. Operating conditions VF 60 100 Maximum flow water temperature °C 80 Temperature Limit thermostat °C 100 Maximum working pressure hPa (bar) 4000 (4,0) Minimum working pressure hPa (bar) 1000 (1,0) Minimum water flow rate : primary / secondary circuits (P/20) l/s 0.67 / 0.67 1.11 / 1.11 Water content l 6,1 9,4 Dry weight kg 73 88 1.4. Electrical conditions

  • page 5/17 2. Boiler installation Installation and maintenance of the installation shoukd be carried by a qualified engineer according to the recommendations of the relevant codes of practice and of the boiler manufacturer The boiler must be installed in an appropriately ventilated compartment …………………………………�

  • Atlantic VF 40, page 6/17 7. Boiler Control Panel 7.1. Control panel fascia 7.2. Display The screen supplies boiler function, time, hourly programme, temperature, burner, condition and defect Hourly programme Space heating requirement Time Boiler temperature DHW requirement Symbols : DHW in progress Space heating in progress Comfort requirement Set back requirement Outside temperature Flame established Defect Touch requirement Touch programme Touch informa

  • page 7/17 When a defect (not stopping the boiler) occurs, the defect code (as E140) is displayed. When a defect causes the boiler to lockout, the lock out code as (E133) and a small bell is displayed. Check error list for explanation 7.3. Control panel functions Touch Selection of different

  • Atlantic VF 40, page 8/17 Auto SBoiler operation to time programme between Comfort and Eco Power C Boiler fires at full power for 3 seconds Regulator Allows manual adjustment of the burner

  • Atlantic VF 40, page 9/17 DHW in Operation DHW not active 7.4. Adjustment of the settings Adjustment of the boiler constant flow temperature In mode - boiler constant flow temperature - regulation from 20degC to 80degC In mode - external temperature - regulation from 10degC to 26degC • • Touch the radiator symbol By touch or select the boiler consta

  • Atlantic VF 40, page 10/17 4.5. Information on boiler condition Touch Information in order 1 DHW temperature 2 Out of action 3 Burner function 4 Outside temperature 5 Error code 6 Boiler flow temperature To revert to standard display, press radiator or tap symbol

  • Atlantic VF 40, page 11/17 List of available information behind the Display First touch - information Press both vertical arrows simultaneously for 3 seconds The time information is replaced by a letter (b,C,d) and a number (0 to 7) By touching the vertical arrows, change the letter By touching the + or -, change the number Display Information b0 Defect is present b1 Boiler return temperature b2 - b3 Flue gas temperature b4 Outside temperature b5 b6 b7 Mixed flow tempe

  • Atlantic VF 40, page 12/17 With a boiler defect leading to a lock-out on the LMU controller the alarm signal is displayed against the defect indicator. To re-set the LMU controller, clear the defect then press the re-set button for 2 seconds Defects Indicator Explanation 0 10 Faulty outside sensor 20 Faulty boiler flow sensor 28 Faulty flue gas sensor 32 Faulty clip-in sensor 40 Faulty boiler return sensor 50 Faulty DHW sensor 61 Weather co

  • page 13/17 Burner operating cycle To view the burner cycle, press the information sign 3 times Code Explanation 0 Boiler at rest (no load) 1 Start up has failed 2 Burner fan starts up 3 Air purge 4 End of pre-ventilation period 5 Ignition 6 Flame established 10

  • Atlantic VF 40, page 14/17 5. Function of the LMU64 060D168 Controller Légende : WDPS = water differential pressure switch, WPS = water pressure switch LS = limit thermostat = Alarm =Flame established =Ignition electrode =Air pressure switch =gas valve = Burner fan N maxi = maximum speed allowed. N ignition = speed at ignition. N mini = minimum speed allowed during modulation N stop = speed less than 200rpm NOTE : Should ignition fail at start up, the LMU will initiate 1 to 4 further attempt

  • Atlantic VF 40, 0RNOxxxx-#_TR Utilisation Entretien VARFREE page 15/17 9. Table of boiler settings for the Client Boiler :..................................... Location : ........................................................... Series No :.................................... ........................................................... Please record all changes to settings ! Reading Function range standard setting Client setting setting

  • Atlantic VF 40, 0RNOxxxx-#_TR Utilisation Entretien VARFREE page 16/17 Reading Function range standard settings Client setting Adjusting the heating circuits H 536 boiler fan RPM when in heating mode ( 60 / 100 ) 0 … 9950 tr/min 5650 / 6400 H 542 minimum boiler output ( 60/ 100 ) 0 … 9999 kW 14 / 25 H 543 maximum boiler output ( 60/ 100 ) 0 … 9999 kW 58 / 95 H 544 Temporary stop on the pumps. 0 … 255 min 5 H 545 minimum time pause of the burner 0 … 3600 sec 150 H 551

  • Atlantic VF 40, 0RNOxxxx-#_TR Utilisation Entretien VARFREE page 17/17 Reading Function Range standard settings Client setting 2 modem inverter 5 listed output H 619 Function of 1st outlet : 0 out of action 6 DHW circulator on 2 lock-out 7 air purge in action 3 burner on 8 shunt pump on 5 2nd pump circuit on 12 analogue circuit active 2 H 620 Function of 2nd outlet: 0 out of action 6 DHW circulator on 2 lock-out

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ALPATEC TF 118 CIT Operation & user’s manual alpatec/tf-118-cit-4GF.pdf 25 Nov 2023 8 0.11 Mb
2 Mitsubishi FX2N-64CL-M Operation & user’s manual mitsubishi/fx2n-64cl-m-O32.pdf 06 Jul 2023 3
3 Pro-Line Boats 20 Owner's manual pro-line-boats/20-CLI.pdf 13 Aug 2022 26
4 Toshiba e-studio2330c Service manual toshiba/e-studio2330c-738.pdf 14 Jan 2023 1248
5 Makita LC1230 Technical information makita/lc1230-YPI.pdf 02 Jan 2024 9
6 Mode com MC-5030 Instruction manual mode-com/mc-5030-17S.pdf 05 Sep 2022 48

Similar Resources:

  • Beretta

    MYNUTE GREEN 50 R.S.I.

    (198 pages)
    INSTALLATIONS MURALESPOWER GREEN 50HIGH POWER WALL-MOUNTED CONDENSATION BOILERSCHAUDIÈRES MURALES À CONDENSATION À HAUTE PUISSANCEHOCHLEISTUNGS-KONDENSATIONSKESSEL FÜR DIE WANDMONTAGECALDERAS MURALES DE CONDENSACIÓN DE ALTA POTENCIAKONDENZACIJSKI STENSKI KOTLI VELIKE MOČIZIDNI KONDENZACIJSKI KOTLOVI VISOKE UČINKOVITOSTI  …
  • Viessmann

    Vitocell 200 Cylinder

    (32 pages)
    Design, Installation,User & ServicingInstructionsAn unvented hot water storage appliance complying with the requirements of Building Regulations Approved Document G3 and manufactured in accordance withBS EN 12897, the specication for unvented water storage vessels. In the interest of continuously improving the Vitocell 200 Cylinder range, Viessmann re …
  • LK

    241 84 64

    (3 pages)
    LK Electric Portable Boiler comprises of:1. Electrically-heated boiler, 9 kW2. Control box3. Expansion tank, 12 litres4. Safety valve, 1.5 bar5. Pressure gauge6. Automatic air-bleed valve7. Circulation pump, Grundfos UPM3 Auto 15-708. Steel-reinforced connection hose 1”, length 1.0 m9. Cable with 3-phase coupling connector, length 1.0 m10. Operati …
  • Viessmann

    VITOCROSSAL 300

    (32 pages)
    Installation instructionsfor contractorsVIESMANNVitocrossal 300Type CT3B, 187 to 635 kWGas condensing boilerVITOCROSSAL 3005800301 GB 9/2018Dispose after installation. …
  • Viessmann

    Vitodens 111-W

    (60 pages)
    Installation and service instructionsfor contractorsVIESMANNVitodens 111-WType B1LD, 4.7 to 35.0 kWGas condensing storage combi boilerNatural gas and LPG version Gas Council Number: 47-819-43, 47-819-44VITODENS 111-W5697789 GB 3/2019Please keep safe. …
  • LAMBORGHINI

    INOVA L 20 MC TOP - SCHEMA

    (100 pages)
    CALDAIA MURALE A GAS - ALTO RENDIMENTO - MODULANTEWALL-HUNG GAS BOILER - HIGH EFFICIENCY - MODULATINGCALDERA MURAL A GAS - ALTO RENDIMIENTO - MODULANTECALDEIRA DE PAREDE A GÁS - ALTO RENDIMENTO - MODULANTEMANUALE DIINSTALLAZIONE EMANUTENZIONEINSTALLATIONAND MAINTENANCEMANUALMANUAL PARALA INSTALACIÓN YEL MANTENIMIENTOMANUAL DEINSTALAÇÃO EMANUTENÇÃOPREGA …

Comments, Questions and Opinions: