Mobeye CM2400 Operation & User’s Manual

Mobeye CM2400 Manual Online:

3.9, 1051 votes
Mobeye CM2400 User Manual
Mobeye CM2400 User Guide
Mobeye CM2400 Online Manual

Text of Mobeye CM2400 User Guide:

  • Mobeye CM2400, CONTENT 1. General description 1 2. Getting started 2 2.1 Insert a SIM card 2 2.2 Insert the batteries 2 2.3 Enter the program mode 2 2.4 Program at least one telephone number 2 2.5 Mount the GSM module housing to the ceiling 3 2.6 Fix the cover to the GSM module housing 3 2.7 Connect the EI detector and close the cover 3 2.8 Perform a test 3 3. Several detectors in a wireless network 4 4. Use of external power supply 5 5. Configuration 6 5.1 Program mode 6 5.2 The (security) code 6 5.3 Programmi

  • Mobeye CM2400, 1 1. GENERAL DESCRIPTION This manual is applicable for the Mobeye CM2400 and the Mobeye CM2400H. The CM2400 is a battery operated GSM module used to send out an alarm after the input is triggered by the EI Electronics smoke detector EI605TYC. The CM2400H is a battery operated GSM module used to send out an alarm after the input is triggered by the EI Electronics heat detector EI603TYC. In this manual the products are referred to as CM2400(H). The Mobeye CM2400(H) has following behaviour. - In case the input of the alarm module is activated by the EI Electronics detector, the Mobeye CM2400(H) sends an alarm SMS text message and

  • Mobeye CM2400, 2 2. GETTING STARTED To get started with the Mobeye CM2400(H) at least the following steps need to be taken in following order: 1. Place a SIM card (with PIN code 0000 or without PIN code) 2. Place the batteries 3. Enter the program mode 4. Program at least one telephone number (administrators’ number) 5. Mount the GSM module housing to the ceiling 6. Fix the cover to the GSM module housing 7. Connect the EI Electronics detector and close the cover 8. Perform a test These steps are further explained in this chapter. After these steps the module will

  • Mobeye CM2400, 3 2.5 MOUNT THE GSM MODULE HOUSING TO THE CEILING Mount the housing in which the module is fixed to the desired place to the ceiling, using the plugs and screws. Please refer to the manual of the EI Electronics detector for het ideal location. 2.6 FIX THE COVER TO THE GSM MODULE HOUSING Take the back cover of the EI Electronics detector. Screw this part to the housing of the GSM module. A small opening shows the exact place. Lead the green connector through the hole in the back cover. Take care the cables are not jammed. 2.7 CONNECT THE EI DETECTOR AND CLOSE THE COVER Press the cabled connector to the pins of the EI Electronics detector. Ne

  • Mobeye CM2400, 4 3. SEVERAL DETECTORS IN A WIRELESS NETWORK Although the Mobeye CM2400(H) can run as stand-alone unit, it is also possible to form a wireless network with several EI detectors. For this purpose each EI Electronics detectors needs to be equipped with an RF module. This module can be integrated in the EI Electronics detector. Before the detectors are operational, the detectors need to enrolled, in order to know each other. The placement of the RF modules in the EI Electronics detectors and the enrolment need to be done before all other steps in chapter 1. Please refer t

  • Mobeye CM2400, 5 4. USE OF EXTERNAL POWER SUPPLY Although the Mobeye CM2400(H) is designed to run on batteries, it is possible to use an external power supply. In this mode the module is always in connection with the GSM network and therefore always in program mode. In case the power fails, the batteries take over the functioning and the administrator is informed by an SMS text message. The module continues operating albeit in the low power mode. This means the GSM module switches off and only establishes network connection in case it needs to send out an alarm, test message or low battery alert. Connect the external power adapter (or any other regulated 12VDC power su

  • 6 5. CONFIGURATION To program the Mobeye CM2400(H), the GSM module must have network connection. In case only batteries are used, first switch the unit to the program mode. Next send SMS commands for the configuration. All settings are stored and will be kept in the unit, even in case the power supplies are removed. 5.1 PROGRAM MODE Directly after inserting th

  • Mobeye CM2400, 7 5.4 LIST OF SMS COMMANDS FOR CONFIGURATION The setting options for the CM2400(H). Setting SMS Command Options Default value Change security code INSTCODE: 0000..9999 1111 Set telephone number for alarm messages TEL1: …. TEL5: Empty Delete telephone number DEL1 …. DEL5 Identification text NAME: 20 characters Mobeye Call on/off CALL: ON, OFF ON SMS on/off SMS: ON, OFF ON Alarm text input 1 TEXT1: 20 characters Fire alarm! Interval ‘test SMS’ TEST: 0..30 (days) 0 Examples: Set phone number 1 : 1111 TEL1:0712345678 Delete phone num

  • Mobeye CM2400, 8 6. POSSIBLE SETTINGS 6.1 PHONE NUMBERS The Mobeye CM2400(H) is able to send alarm messages to up to 5 phone numbers. The first telephone number (TEL1) belongs to the administrator. Only this number receives all system messages. The other phone numbers (including the administrator) only get the alarm messages. To set or change telephone numbers: SMS command 1 st telephone number: TEL1: example: 1111 TEL1:07123456789 .... similar for TEL2:, TEL3:,TEL4 and TEL5: For foreign number, start with + followed by the country code (and depending on the country leave out the zero for the local area code). example: 1111 TEL1:+447123456789 To dele

  • 9 6.6 TEST MESSAGE The Mobeye CM2400(H) can send regular test SMS messages (keep alive) to the administrator (first phone number), to ensure the proper functioning of the unit. The test message function is only active if the unit is armed. The interval between the test messages can be set between 0 days (no test message) and 30 days. The default test inte

  • Mobeye CM2400, 10 7. REQUEST LIST OF THE SETTINGS AND STATUS The programmed settings and status of the GSM detector can be retrieved by SMS message. Before sending the request, make sure the unit is in the program mode (please refer to 5.1). STATUS REQUEST The status of the Mobeye CM2400(H) can be requested by sending an SMS with the content: SMS command status request: STATUS? example: 1111 STATUS? Upon sending this request, the Mobeye CM2400(H) returns the status to the originator of the request. The status message includes the ARMED / NOT CONFIGURED statu

  • Mobeye CM2400, 11 8. TECHNICAL MESSAGES AND STATUS FEEDBACK Technical messages In the event of technical issues the administrator receives an SMS message. Possible technical messages are: Message Reason Low batteries, external power supply OK Power is available, batteries need to be replaced No external power supply, batteries OK No external power supply, batteries are able to take over operation in low power mode Low batteries, no external power supply No external power supply, batteries need to be replaced External power supply OK, batteries OK The external power is restored (or

  • 12 Technical specifications GSM : Quad band EGSM, 850/900/1800/1900 MHz Batteries : 2* CR123 (lithium) Battery life in normal mode : >1 year Ext. power connection : 12 VDC (+/- 2 VDC) / min. 500 mA. (optional) Power consumption low power : ca 50 μA. stand-by / max. ca. 500 mA Power consumption 12V : ca 50 mA. stand-by / max. ca. 500 mA D

  • Mobeye CM2400, 13 Declaration of Conformity Herewith we, Mobeye, declare that the product Mobeye CM21 telemetry module And the derived products CM2000, CM2100, CM2200, CM2300, CM2300FS, CM2400, CM2500, CM2600 are in compliance with the essential requirements of the following European standards / EU Directives: Directive 73/23/EEC (low voltage directive) Directive IEC/EN 50130 Electromagnetic compatibility Directive 1995/5/EC R&TTE (Radio & Telecommunications Terminal Equipment) The conformity with the essential requirements of 1995/5/EC has been verified against: ETSI EN 301 489-1 V1.5.1

More Instructions:

DOWNLOAD

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Acapella Audio Arts Duke Instruction manual acapella-audio-arts/duke-328.pdf 12 Jul 2023 9
2 Temco 33RDVDSN Installer/consumer safety information manual temco/33rdvdsn-33Y.pdf 16 Mar 2023 44 2.39 Mb
3 Cisco WS-C3550-12G Datasheet cisco/ws-c3550-12g-2JM.pdf 14 Oct 2022 18 0.16 Mb
4 Optiquest Q2161WB - Optiquest - 21.6" LCD Monitor Specification sheet viewsonic/q2161wb-optiquest-21-6-lcd-monitor-G3T.pdf 02 Nov 2023 2 0.36 Mb
5 Tunstall Find-Me Operation & user’s manual tunstall/find-me-948.pdf 04 Jun 2023 9
6 Cub Cadet CC 760ES Illustrated parts manual cub-cadet/cc-760es-SNJ.pdf 20 May 2023 28 3.77 Mb

Similar Resources:

  • Televes Integra

    7658

    (2 pages)
    Detector de Humo ÓpticoSmoke DetectorRef. 765801El 7658 es un detector óptico de humo, que proporciona una salida derelé y se puede utilizar como parte de un sistema de alarma doméstica.Si se detecta humo, el 7658 emitirá un sonido de alarma y su salida derelé se disparará. El detector realiza autochequeos de forma regular e informa de suestado gracia …
  • B.E.G.

    LUXOMAT SD1

    (2 pages)
    Assembly and operating instructions for B.E.G.’s SD1 smoke detectorTested according to EN 14604:2005 as appropriate.2. Avoid these sitesDo not fit the smoke detector in: − Kitchen– kitchen smoke could active the alarm un-intentionally. − Garage – residue from combustion is produced when you start your car. − In front of heating or air condi …
  • NAPCO

    GEM-SM

    (4 pages)
    Description.Description. The GEM-SMK is a high-quality photoelec-tric smoke detector with built-in supervised digitally-codedradio transmitter. It is compatible with Napco’s GEM-RECVSeries supervised security receivers that monitor alarms,restores, low battery and status.The GEM-SMK sounds a local alarm as soon as smoke isdetected and the transmitter will …
  • Dyna-Glo

    DGY784BDP

    (15 pages)
    MODEL #DGY784BDP/DGY784BDP-DVERTICAL GAS SMOKERFrançais p. XXEspañol p. XXFrançais p. 28Español p. 55ATTACH YOUR RECEIPT HERESerial NumberPurchase DateQuestions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-447-4768, 8:00 a.m. – 4:30 p.m. CST, Monday – Friday or email customerservice@ghpgro …
  • Abus

    RM20

    (64 pages)
    – 1 –RM20 Rauchwarnmeldermit HitzewarnfunktionBedienungs-, Installations- und Wartungsanleitung Rauchwarnmelder mit HitzewarnfunktionDUser manualSmoke alarm device with heat alarm functionGBConsignes d‘utilisation et d‘installationDétecteur d‘alarme de fumée avec signal d‘avertissement de chaleurFGebruikers- en installatiehandleidingRookmelder …
  • System Sensor

    D4P120

    (8 pages)
    Page 1INSTALLATION INSTRUCTIONS FOR SMOKE DETECTOR KITS(11K76 & 11K80; 603408-09 & 603408-10) USED WITH KC/KG/KH/LC/LG092 - 152 UNITSLitho U.S.A.506437-011/2015Supersedes 10/2012E2015D4P120 & D4SSMOKE DETECTOR KITSPACKAGED UNITS KITSAND ACCESSORIESShipping and Packing ListSupply OR Return Air Applications11K76 single-sensor kit contains the follo …

Smoke Alarm Instructions:

Comments, Questions and Opinions: