  • remote control clears sleeping mode away. Attention:  Aimed the remote control at the receiver on the air-conditioner.  The remote control should be within 8 meters away from the receiver.  No obstacles between the remote control and receiver.  Don’t drop or throw the remote control.  Don’t put the remote control under the strong sunrays or heating facili

  • AUX ASW-H07B4/HSAR, 4 Chapter 2 Operating Principle . Cooling After the power supply is switched on, the machine is set to COOL mode. With the compressor being operated, the low-temperature and low-pressure refrigerant vapor is sucked into the compressor where it is turned into high-temperature and high-pressure gas. Then it is cooled down in the outdoor heat exchanger by the air and becomes liquid. After being throttled by the capillary, the refrigerant liquid comes into the indoor unit and then it evaporates in the indoor heat, exchanger, absorbing heat and reducing the r

  • AUX ASW-H07B4/HSAR, 31 remote control clears sleeping mode away. Attention:  Aimed the remote control at the receiver on the air-conditioner.  The remote control should be within 8 meters away from the receiver.  No obstacles between the remote control and receiver.  Don’t drop or throw the remote control.  Don’t put the remote control under the strong sunrays or heating facilities and other heating sources.  Use two AAA batteries, don’t use rechargeable batteries.  Take the batteries out of remote control before stop usin

  • AUX ASW-H07B4/HSAR, 25 13.Self-checking function of controller After the automatic button is pressed, the air conditioner will be powered on and enter into the process of self-checking: Buzzer sounds two times→ operation indicator turns on→ timing indicator turns on→compressor acts→four-way valve acts→outdoor fan acts→electric heating acts→indoor fan acts→buzzer sounds one time which means that air conditioner goes into the state of order-waiting and the self-checking comes to an end. 14. Remote control Name and functions of the button on the remote control

  • AUX ASW-H07B4/HSAR, COOL SERIES HEAT PUMP Outdoor unit electric connection diagram Chapter 8 Fault Analysis of the Product Available and Typical Examples 1 Procedure of deciding the faults Before maintaining the air conditioner, firstly you should know the phenomena of the faults decide the location of the faults, analyze the reason the faults occur, and then search for ways to solve the faults. The detailed procedures are: Look, Listen, Touch, Measure, Analyze  Look: Observe air conditioner’s running. I.

  • AUX ASW-H07B4/HSAR, 10.6 Function of charatron display When the controller is normal, there will be no charatron display under the circumstance of power-off. When air conditioner is powered on, the charatron will display room temperature under the normal situation. If the temperature set is changed, the charatron will show the temperature set which sparkles at the rate of 1 time per second. Then it will display room temperature once again in 5 seconds. The display range of room temperature is 0~79. 11. F

  • AUX ASW-H07B4/HSAR, 23 10.6 Function of charatron display When the controller is normal, there will be no charatron display under the circumstance of power-off. When air conditioner is powered on, the charatron will display room temperature under the normal situation. If the temperature set is changed, the charatron will show the temperature set which sparkles at the rate of 1 time per second. Then it will display room temperature once again in 5 seconds. The display range of room temperature is 0~79. 11. Function of breakdown indication HS, HSA series (charatron); HV (VFD display) Breakdown cause Dis

  • AUX ASW-H07B4/HSAR, it lowers to less than 30, the indoor fan will be shut down; And the time when the afterheat blows will last less than 40 seconds after the indoor fan is turned off. 6.7 Defrosting operation: 6.7.1The conditions upon which the outdoor sensor goes into operation are as below: 1. Under the circumstance of heating, if T external coiled pipe is at the temperature of less than -6 which lasts 2 minutes and the accumulated working time of compressor reaches more than 50 minutes (if there is any power cut-off or shut-down by remote control, the accumulated working time of compressor shall be re-calculated), the defrosting interval will be more than 50 minutes and the compressor

  • AUX ASW-H07B4/HSAR, 43 z If it is an overhanging installation, the structure of the mounting wall should be made of solid, cement or materials with equivalent strength, and of sufficient support capacity. Otherwise, measures such as reinforcement, support or vibration damping should be adopted. Installation of the Indoor Unit z First make changes to wall and make sure that is hard and secure. Using four “+” type screws to fasten the installation board onto the wall. Keep it level in horizontal direction and perpendicular in vertical direction. Otherwise it might cause water drips when air-conditioner is running in cooling operation. z Drill 70mm diameter pi

  • AUX ASW-H07B4/HSAR, will increase. (8) Setting button▼: Press the button, the setting temperature or timer will decrease. (1) Mode display: press the MODE button, it shows the current operation mode. You can select “Automatic”, “Cool”, “Dry”, and “Fan”“heat” operation mode. (cold wind type has no heating mode) (2) Sending display: when the remote control sends correct and effective signal each time, the sign displays intermittently each time. (3) Fan speed display: press the “WIND” button, the fan speed will display. You can select fan speed from “Power”, “High”, “Low”, and “Mute”. (4)Number displa

  • AUX ASW-H07B4/HSAR, 53 Wrong running mode of indoor units set Check if running mode of two indoor units is the same( it is not available if one is heating and another is cooling Reset 3.8 Cannot receive the remote control signal Reason Check to be made Proposed Remedy Damaged remote control or low battery Check if the indication is normal Replace the remote control or battery Short-circuit of connections of main control board to switch board Check the board Replace the components Running mode of two indoor units i

  • AUX ASW-H07B4/HSAR, it lowers to less than 30, the indoor fan will be shut down; And the time when the afterheat blows will last less than 40 seconds after the indoor fan is turned off. 6.7 Defrosting operation: 6.7.1The conditions upon which the outdoor sensor goes into operation are as below: 1. Under the circumstance of heating, if T external coiled pipe is at the temperature of less than -6 which lasts 2 minutes and the accumulated working time of compressor reaches more than 50 minutes (if there is any power cut-off or shut-down by remote control, the accumulated working time of compressor shall be re-calculated),

  • AUX ASW-H07B4/HSAR, 19 The power-off at a fixed time can be set only if the air conditioner is on. And it continues to work though the power-off at a fixed time has been already set. When it comes to the fixed time, the indoor and outdoor fans will be shut down. 8.4 Power-on at a fixed time The power-on at a fixed time can be set only if the air conditioner is on. And it continues to be off though the power-on at a fixed time has been already set. When it comes to the fixed time, the indoor and outdoor fans will start to operate. 9. Emergency switch When the soft-touch switch is pressed, the air conditioner will be powered on and th

  • AUX ASW-H07B4/HSAR, 10 conditioner will work under the mode of dehumidification (always mute). 2.4 When the indoor temperature reaches less than 20, the air conditioner will work under the mode of heating. 2.5 Under this mode, the air conditioner will operate in the respect of blowing rate as set and its pendulum leaves will work according to the requirements of automatic ventilation door. 2.6 Once the operation mode is selected, it will not be able to be changed. When the air conditioner is shut down and then restarted, the operation mode will be selected

  • AUX ASW-H07B4/HSAR, remote control clears sleeping mode away. Attention:  Aimed the remote control at the receiver on the air-conditioner.  The remote control should be within 8 meters away from the receiver.  No obstacles between the remote control and receiver.  Don’t drop or throw the remote control.  Don’t put the remote control under the strong sunrays or heating facilities and other heating sources.  Use two AAA batteries, don’t use rechargeable batteries.  Take the batteries out of remote control before stop using for long. �

  • 16 6.7.3 The requirements of defrosting operation: 1. Sleep indicator flickers at the speed of 1 time per second 2. When defrosting operation starts, the compressor and indoor fan will stop working while outdoor fan and four-way valve will continue to work. 3. The four-way valve and outdoor fan will stop operating in 30 seconds. 4. 15 seconds afte

  • AUX ASW-H07B4/HSAR, ·Emergency operation button of indoor types: Compulsory button 1) When the air-conditioner works with the absence of remote control, it will stop working by pressing the compulsory button and it will resume working by pressing the compulsory button once again. 2) When remote control is useless, you can adopt the compulsory operation by which the air conditioner will go into automatic operation mode. ·The operation interface of remote control: Features of products 1. Fashionable appearance 2. Compact

  • AUX ASW-H07B4/HSAR, 5.Clean breath efficient biological antibacterial filter gauze made from green plant elite refined by using international leading technology, with the function of filtering and suppressing bacteria, and able to absorb and kill various pathogens and harmful gases efficiently for a long period, prevent secondary pollution caused due to microorganism spreading, and ensure the health of your family 6. R407c cold medium is applied, environment-friendly, and avoid damages to ozonosphere 7. International famous-brand Toshiba Hitachi and Matsushita compresso

  • Chapter 6 Dismantling Procedure Indoor Unit Operating step Photo 1. To remove the panel and connecting wire cover. · Take off the screws of the connecting wire cover and remove the cover. · Then remove the panel. 2. To remove the air filter.

  • Chapter 3 operation details 1. Overall 1.1 Protection of compressor Whatever operation modes the air- conditioner is under, there will always be 3 minutes' time- delay protection unless it is on for the first time. When the compressor is switched on, it can not be shut down within 3 minutes (except under the modes of heating or defrosting) unless it is powered off or its opera

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Uniden UH089 Owner's manual uniden/uh089-U5P.pdf 25 Aug 2023 16 0.57 Mb
2 RCA G36710 Technical specifications rca/g36710-3QD.pdf 04 Jun 2023 2 0.15 Mb
3 ProForm 380 P Treadmill Manual  proform/380-p-treadmill-J15.pdf 04 Dec 2022 32
4 Panasonic EB-MX6 Operating instructions manual panasonic/eb-mx6-6FH.pdf 31 Dec 2023 162 4.02 Mb
5 Mercedes-Benz 2004 CLK-Class Cabriolets Operator's manual mercedes-benz/2004-clk-class-cabriolets-WFH.pdf 07 Aug 2023 464
6 ViewSonic PJ557D - XGA DLP Projector Specifications viewsonic/pj557d-xga-dlp-projector-LWI.pdf 16 Sep 2023 2 1.31 Mb

Similar Resources:

  • LG

    S18TQC

    (48 pages)
    ENGENGLISHENGAIROWNER’S MANUALCONDITIONERwww.lg.comPlease read this manual carefully before operating your set and retain it for future reference.TYPE : WALL MOUNTEDRev : 01 (05T16)*MFL69284014* …
  • Mitsubishi Electric

    PCA-RP·KAQ

    (184 pages)
    Air-ConditionersPCA-RP•KAQEnglishDeutschFrançaisNederlandsEspañolItalianoPortuguêsDanskSvenskaINSTALLATION MANUALFor safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.INSTALLATIONSHANDBUCHAus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlag …
  • Toshiba

    RAS-10 series

    (8 pages)
    ăĕČĕģúąENGLISHAIR CONDITIONER (SPLIT TYPE)For general public useIndoor unitRAS-10, 13, 18, 25N3KPX-TRAS-13, 18, 24N3KPX-INOutdoor unitRAS-10, 13, 18, 25N3AX-TRAS-13, 18, 24N3AX-INOWNER’S MANUAL1110650165TSB_1110650165.indb 1TSB_1110650165.indb 19/3/2012 10:459/3/2012 10:45 …
  • Fujitsu

    AUU9RLF

    (210 pages)
    AIR CONDITIONERMulti : 2rooms type 3rooms type 4rooms typeINDOOROUTDOORDESIGN & TECHNICAL MANUALAUU9RLFAUU12RLFAUU18RLFARU9RLFARU12RLFARU18RLFAOU18RLXFZAOU24RLXFZAOU36RLXFZASU18RLFASU24RLFARU24RLF ASU7RLFASU9RLFASU12RLF …
  • Panasonic

    CS-MKE9NKU

    (2 pages)
    Split System Submittal DataIndoor: CS-MKE9NKU Multi System Indoor Units - Wall MountedApproval:Date:Construction:Unit#:Drawing#:Job Name:Location:Engineer:Submitted to:Submitted by:Reference:General DataPower (V/P/Hz) 208 - 230/1/60Circuit Ampacity (A) 15Fuse Size, Max.(A) 20Running Amps (A) 0.15Power Input (W) 35Indoor Unit Cool/HeatFan type Cross FlowDia …
  • Midea

    Blanc Series

    (2 pages)
    Blanc High Wall Quick Step Installation Guide Step 1: Prior to unpacking equipment please inspect boxes for any transport damage to ensure products are in perfect condition. Step 2: Ensure the equipment model numbers on the boxes correspond with your companies purchase order. Step 3: Unpack the equipment and ensure all parts are accounted for i.e …

Comments, Questions and Opinions: