  • PD Technology 350, P D Technology Ltd PDT Power Series Instruction Manual Domestic, Commercial & Industrial 350, 500, 650 and 1000 MODELS P D Technology Ltd ‘Controlling The Future’ PLEASE READ THE INSIDE FRONT COVER BEFORE INSTALLING THE PDT POWER SERIES www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk

  • PD Technology 350, IMPORTANT WIRING INFORMATION: Before installing the Battery Back Up System please pay attention to the information given below. Incorrect Installation will cause the Battery Back Up System to function incorrectly and may result in damage to the Battery Back Up. CORRECT INSTALLATION METHOD: INCORRECT INSTALLATION METHOD: Note: • Never add an additional loop from the Battery Back Up system into the mains power. • Never add an additional loop from the P D Technology Control Unit into the mains power. Both of the above will cause serious damage to the Battery Back Up Sy

  • 1 CONTENTS IMPORTANT SAFETY INSTRUCTIONS 2 - 3 Front View of PDT Power Series 4 Rear View of PDT Power Series 5 WHAT’S INCLUDED 6 INSTALLATION 7 CONTROLS AND INDICATORS 8 ON/OFF/Alarm Silence Button 8 Status Indicators: Mains, Battery, Fault, Standby 9 Mains Indicator (Green/Amber)

  • PD Technology 350, 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the Uninterruptible Power System (UPS) and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS. Read all safety, installation, and operating instructions before operating the UPS. Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. This equipment can be installed and operated

  • PD Technology 350, 3 CAUTION BATTERY HANDLING PRECAUTIONS Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from the batteries. A battery can present a risk of electrical shock and high short-circuit current. The following precautions should be observed when working on batteries: • Remove watches, rings, and other metal objects. • Use tools with insulated handles. • Do not dispose of battery or batteries

  • PD Technology 350, 4 FRONT VIEW OF BATTERY BACK UP POWER ON/OFF Alarm Silence* MAINS INDICATOR* (Green/Amber) FAULT INDICATOR* (Red/Green) BATTERY INDICATOR* (Green/Amber) * For details s ee controls and indicators section STANDBY MODE LED* (Red) SHIPPING BUTTON * (Concealed) www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk

  • PD Technology 350, 5 REAR VIEW OF BATTERY BACK UP SYSTEM O RANGE OUTPUT RECEPTACLES* (Battery Back Up and Surge Protection) BATTERY COVER PLATE BLACK OUTPUT RECEPTACLES* Do Not Use INPUT CIRCUIT PROTECTOR MAINS/ POWER ORANGE OUTPUT RECEPTACLES* (Battery Back Up and Surge Protection) 350, 500 & 650 MODELS 1000 MODEL BLACK OUTPUT RECEPTACLES* Do Not Use INPUT CI RCUIT PROTECTOR MAINS/ POWER BATTERY COVER PLATE (Underneath Unit) ww

  • PD Technology 350, 6 WHATS INCLUDED The P D Technology Power Series Unit is shipped with the following items. • P D Technology User Manual • Two 10A power cords, 2.0m (1 Output & Input and 1Mains Plug & Input) P D Technology Power Series Two 10Amp power cords (2.0 meters) (1 Output & Input and 1 13Amp Mains Plug & Input) www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk

  • PD Technology 350, 7 INSTALLATION This PDT Power Series is designed for all types of Roller Shutters. Maximum load must not exceed that shown on the Power Series rating label. Do not connect equipment that could overload the unit or draw half-wave current from it. Your total load earth leakage current must not exceed 3.5 mA. 1. Visually inspect the unit for freight damage. Report damage immediately. 2. Decide where to place the PDT Power Series. Find a location that is near an easily accessible mains outlet. Install the unit indoors in a controlled environment. Place it in an area of unrestricted airflow around the u

  • 8 CONTROLS AND INDICATORS ON/OFF/Alarm Silence Button This button controls output power to the connected load and has three functions: • ON • OFF • Alarm Silence ON When the unit is off, pressing and releasing the main ON/OFF button will start the unit, and an audible alarm sounds briefly. The unit is capable of starting on battery

  • 9 Status Indicators: Mains, Battery, Fault, Standby There are four status indicators on the front of the unit (Mains, Battery, Fault and Standby), as shown in the diagram below. Each indicator illuminates to specify the status of the unit (see Troubleshooting section for details). Mains Indicator (Green/Amber) The Mains Indicator illuminates

  • PD Technology 350, 10 MODES OF OPERATION Normal Mode During normal mode operation, the PDT Power Series supplies conditioned power, to the connected equipment: mains power passes through the TVSS circuitry and the EMI/RFI filters and then through the Bi-Directional Converter to connected equipment. When the unit is in Normal mode, the Mains Indicator illuminates green. The PDT Power Series continuously monitors the batteries to maintain them in a fully charged state. The battery charger operates whenever AC power is present, even if the un

  • PD Technology 350, 11 Battery Mode The unit switches to battery mode in the event of an extreme voltage/frequency condition or complete mains failure. The battery system supplies power through the Bi-Directional Converter to generate power for connected equipment. When the unit is in Battery mode, the Battery Indicator illuminates green and an alarm sounds every 10 seconds. When a low battery condition occurs, the Battery Indicator changes to flashing amber and the alarm sounds every half-second. For more information, refer to Troubleshooting section. CAUTION Turning of

  • PD Technology 350, 12 Standby Mode When the mains power fails, the battery back up will go in to 24-hour standby mode. Within the first 24 hours of a power failure the unit can be woken up immediately with either a key switch or a key fob input. After 24 hours in order to preserve battery life the unit goes in to a seven second cycle. This mode will allow the unit to work for 100 days without power and still be able to operate the shutter when required. Standby Indicator ON = Standby Mode Standby Indicator Flashing Every 5 Seconds indicates pow

  • PD Technology 350, 13 Dip Switch Modes VOLTAGE DIPSWITCHES - LOCATED ON BACK OF UNIT The unit is shipped out pre-set to 230 volts for operation. Under NO circumstances should the dip switches be adjusted whilst the unit is switched on. Please contact PDT before making any adjustment to this setting, as wrong voltage dip switch settings can seriously affect the safety features of the shutter when used with a RollerTec control system. FUNCTION DIPSWITCHES – LOCATED INSIDE FRONT COVER Note: Before carrying out any dipswitch adjustments the unit should be isolated from the mains and have its battery disconnected.

  • PD Technology 350, 14 Key Switch Inputs Volt free contacts on a key switch or other control device can be wired across terminal J3, which is, situated behind the PDT Power Series front cover. The contacts should be Normally Open, closing when the PDT Power Series is required. The unit will stay active for 25/45 seconds after the contacts are opened, or for as long as the contacts are closed up to a maximum time of 5 mins, at which point an auto shut down will occur. This is to safeguard against a stuck closed key switch from discharging the batteries. ROUTING YOUR CABLE: On the bottom of the front

  • PD Technology 350, 15 Battery Replacement Procedure Replacement requires removing the battery cover plate on the back or bottom of the unit. No tools are needed. To replace the batteries: 1. Remove the battery Figure 1 Figure 2 cover plate on the back/ bottom of the unit (Figure 1). 2. Pull the white tabs towards you to remove the battery from the unit (Figure 2). 3. Disconnect the insulated connectors Figure 3 Figure 4 from the battery terminals (Figure 3). 4. Insert a

  • PD Technology 350, 16 TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the PDT Power Series experiences a problem. Use this information to determine whether external factors caused the problem. See Troubleshooting Chart for suggested remedy. 1. The Fault indicator illuminates, indicating the unit detected a problem. 2. An alarm sounds, alerting that the unit requires attention. The alarm can be silenced except for low battery, overload warning and over-temperature warning conditions. 3. Mains and/or Battery indicators may be illuminated as

  • PD Technology 350, 17 Troubleshooting Chart If the unit fails to operate properly, turn off the unit and repeat the steps in the Installation section of this manual. If the problem persists, refer to the chart below: Problem Cause Solution Overload/ Short circuit Check the circuit protector on the rear of the unit. If it is tripped, reset it and restart the unit. For further help, contact PDT. Unit will not start Battery disconnected or is completely discharged Check for proper connection of battery or batteries. Unit not plugged in Plug in the power cord securely. Circuit protector tripped Reset the c

  • 18 Technical Specifications: MODEL 350 VA 500 VA 650 VA 1000 VA WATTAGE 210 300 390 600 DIMENSIONS (MM) WxDxH 116X196X222 116X196X222 116X358X222 116X358X222 WxDxH SHIPPING 196X310X293 196X310X293 242X500X316 242X500X316 WEIGHT (KG) UNIT 7 7.4 9.1 13.2 SHIPPING 8.2 8.5 11

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Canon PowerShot G9 Operation & user’s manual canon/powershot-g9-463.pdf 14 Aug 2023 455
2 PRASTEL DOM1-L1SIM Manual  prastel/dom1-l1sim-O9C.pdf 18 Feb 2024 12
3 AOC V22T Operation & user’s manual aoc/v22t-899.pdf 09 Jan 2023 32 5.62 Mb
4 Zanussi FLN1009 Operation & user’s manual zanussi/fln1009-N92.pdf 14 Aug 2023 24 0.41 Mb
5 Radiforce RS110 User manual manual radiforce/rs110-79P.pdf 10 Feb 2024 48
6 Panasonic SHFX71 - WIRELESS SYSTEM Operating instructions manual panasonic/shfx71-wireless-system-JMQ.pdf 06 Jul 2022 12

Similar Resources:

  • INVT

    HT33 Series

    (44 pages)
    -1- HT33 Series User Manual Safety Precautions This manual is about the installation and operation of HT33 Series UPS (Hereinafter referred to as UPS). Please carefully read this manual prior to installation. The UPS must be debugged and maintained by the engineer commissioned by the manufacturer or the agent. Otherwise, human safety may be endangered and t …
  • Minuteman

    Endeavor ED1000RTXL2U

    (16 pages)
    User's ManualEndeavor LCDRTXL UPS SeriesPara Systems, Inc.1455 Lemay Dr.Carrollton, TX 75007Phone: 1-972-446-7363Fax: 1-972-446-9011Internet: minutemanups.comUPS Sizing: sizemyups.comPN - 34000516 R2 …
  • Tripp Lite

    SmartPro VS

    (32 pages)
    1Owner’s Manual1111 W. 35th Street Chicago, IL 60609 USA www.tripplite.com/supportImportant Safety Instructions 2Quick Installation 3Basic Operation 5Storage & Service 10Specifications 11SmartPro® VSIntelligent, Line-Interactive UPS Systems (Tower Configuration) • 120V Input • 2200VA - 3000VA Capacities • Extended-Run OptionsNot suitable …
  • CyberPower

    CP550SL

    (2 pages)
    CP550SL / AE550 User’s Manual K01-AE55000 IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. CAUTION! To p …
  • Emerson

    ECP-024

    (2 pages)
    ECP__65076__R04.doc Replacement for Rev 03 PCN 863 031 Date: 27.10.2008 Installation Instructions Uninterruptible Power Supply ECP-024 Emerson Electric GmbH & Co. OHG Heerstr.111 – D-71332 Waiblingen Tel.: 07151 509-0 - Fax.: -200 www.emersonclimate.eu GB General information and technical data: ECP-024 is intended to be used with ALCO EXD d …
  • Power Innovations

    INTegral 203T

    (31 pages)
    Line-Interactive Uninterruptible Power Supply Unit 2kVATower Model (203T) USER’S MANUAL MNL105-203T Version 1.0 Powering Life …

Comments, Questions and Opinions: