Manualios.com

LG Deluxe High Wall Mini Split Owner's Manual

  • Deluxe High Wall Mini Split Air Conditioner
  • ma1Fq8UQGicLA
  • Owner's Manual
  • PDF / Adobe Acrobat Reader
  • 26

LG Deluxe High Wall Mini Split Manual Online:

3.8, 1395 votes
LG Deluxe High Wall Mini Split User Manual
LG Deluxe High Wall Mini Split User Guide
LG Deluxe High Wall Mini Split Online Manual

Text of LG Deluxe High Wall Mini Split User Guide:

  • LG Deluxe High Wall Mini Split, ENGLISH FRANÇAIS LG Room Air Conditioner LG • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly. IMPORTANT OWNER'S MANUAL website http://www.LG.ca Prior to installation, this air- conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm).

  • LG Deluxe High Wall Mini Split, ############## 2 Deluxe High Wall Mini Split Room Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased ■ Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues. READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time

  • LG Deluxe High Wall Mini Split, Safety Precautions Owner’s Manual 3 ENGLISH Safety Precautions To prevent the injury of the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. ■ The meanings of the symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instru

  • LG Deluxe High Wall Mini Split, Safety Precautions 4 Deluxe High Wall Mini Split Be cautious when unpacking and installing the product. • Shape edges could cause injury. Be especially careful of the sharp edges. For installation, always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. • It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. • If the base collapses, the air conditioner could fall with it, causing property damage, product

  • Safety Precautions Owner’s Manual 5 ENGLISH Do not place a heater or other appliances near the power cable. • There is risk of fire and electric shock. Do not allow water to run into electric part. • It may cause There is risk of fire, failure of the product, of electric shock. Do not store of use flammable gas or combustibles near the air conditioner. • There is risk of

  • LG Deluxe High Wall Mini Split, Safety Precautions 6 Deluxe High Wall Mini Split Always check for gas(refrigerant) leakage after installation or repair of product. • Low refrigerant levels may cause failure of product. Install the drain hose to ensure that water is drained away properly. • A bad connection may cause water leakage. Keep level even when installing the product. • To avoid vibration or water leakage. ■ Installation 90˚ When the product is not be used for a long time disconnect the power supply plug or turn off the breaker. • There is risk of product damage or failure, or unintended o

  • Safety Precautions Owner’s Manual 7 ENGLISH Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. • It may cause a problem for your neighbors. Use two or more people to lift and transport the air conditioner • Avoid personal injury. Do not install the product where it will be exposed to sea wind (salt spray) directly. • It

  • LG Deluxe High Wall Mini Split, Safety Precautions 8 Deluxe High Wall Mini Split Do not drink the water drained from the unit. • It is not sanitary and could cause serious health issues. Use a firm stool or ladder when cleaning or maintaining the air conditioner. • Be careful and avoid personal injury. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. • There is risk of fire or explosion. Do not recharge or disassemble the batteries. Do not dispose

  • LG Deluxe High Wall Mini Split, ENGLISH Owner’s Manual 9 Prior to operation Prior to Operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, ony replace it with an authorized replacement part. 1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time. 2. Ventilate the room when the air conditioner is used wit

  • LG Deluxe High Wall Mini Split, 10 Deluxe High Wall Mini Split Introduction Introduction This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. This symbol indicates special notes. NOTICE Features Symbols used in this Manual Vertical louver Horizontal louver Air filters (behind front panel) Air outlet vent Air inlet vent (Side) (Rear) Air outlet vents Air intake vents Piping Indoor Outdoor • This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.

  • LG Deluxe High Wall Mini Split, ENGLISH Owner’s Manual 11 Temporary Use of an Adapter We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as

  • LG Deluxe High Wall Mini Split, 12 Deluxe High Wall Mini Split Signal receptor Operation indication lamps Operating Instruction How to insert the Batteries Operating Instruction Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. Reattach the cover by sliding it back into position. Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. NOTICE • The remote controler may be stored by mounting it on a wall. �

  • LG Deluxe High Wall Mini Split, ENGLISH Owner’s Manual 13 Operating Instruction Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Heating Operation • Cooling Model( ), Heat Pump Model( ) 6 1 3 5 4 2 Flip-up door (closed) The remote control transmits the signals to the system. Remote Control Operations Operation Mode START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. OPERATION MODE SELECTION BUTTON Used to select the operation mode. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN

  • LG Deluxe High Wall Mini Split, Operating Instruction 14 Deluxe High Wall Mini Split ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. TIME SETTING BUTTONS Used to adjust the time. (See page 20) TIMER SET/CANCEL BUTTONS Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 20) SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. (See page 20) AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating (turns indoor fan on/off). (See page 21) ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. RESET BUTTON Used p

  • LG Deluxe High Wall Mini Split, Operating Instruction Owner’s Manual 15 ENGLISH Natural wind by the CHAOS logic ❏ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. Cooling Healthy Dehumidification Auto Heating (Heat pump model only) To raise the temperature To lower the temperature Cooling Operation Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote

  • LG Deluxe High Wall Mini Split, 16 Deluxe High Wall Mini Split Operating Instruction Cooling Healthy Dehumidification Auto Heating (Heat pump model only) Cooling Healthy Dehumidification Auto Heating (Heat pump model only) To raise the temperature To lower the temperature Auto Operation Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. To select Auto Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. The temperature and fan speed are automatically set by the electronic controls based on

  • LG Deluxe High Wall Mini Split, ENGLISH Owner’s Manual 17 Operating Instruction Cooling Healthy Dehumidification Auto Heating (Heat pump model only) Healthy Dehumidification Operation Mode This mode dehumidifies without overcooling. During Healthy Dehumidification Operation: ❏ If you select the dehumidification mode on the operation selection button, the airconditioner starts to run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp. In this case, howeve

  • LG Deluxe High Wall Mini Split, 18 Deluxe High Wall Mini Split Operating Instruction Cooling Healthy Dehumidification Auto To raise the temperature To lower the temperature Heating (Heat pump model only) Heating Operation(Heat pump model only) Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Close the door on the remote control. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°C (60°F~86°

  • LG Deluxe High Wall Mini Split, ENGLISH Owner’s Manual 19 Operating Instruction or or ❏ During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. Quickly in a hot summer. In the heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL function is not available. ❏ In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again. NOTICE Jet Cool Operation Press the Start/Stop button. The unit will res

  • LG Deluxe High Wall Mini Split, Operating Instruction 20 Deluxe High Wall Mini Split Delay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF Timer Additional features Sleep Mode Setting the Time Delay Start/Pre-Set Stop 1. Press the Sleep Mode Auto button to set the time you want the unit to turn off automatically. 2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner. 3. Make sure the Sleep Mode Auto LED lights up. To cancel the Sleep Mode, press the sleep Mode Auto button several times

  • Operating Instruction Owner’s Manual 21 ENGLISH Fan speed is on low. Fan speed is on medium. Fan speed is on high.CHAOS Air Air Circulation Mode Circulates the room air without cooling or heating. 1. Press the Start/Stop button. the unit will respond with a beep. 2. Open the door on the remote control. Press the Air Circulation button. Close the door on the re

  • LG Deluxe High Wall Mini Split, High Speed FORCEDFORCED OPERATION FORCED OPERATION AUTO RESTART AUTO RESTART 22 Deluxe High Wall Mini Split Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button. Forced Operation Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. If you want to use this operation, press the Auto Restart Button. Helpfu

  • ENGLISH Owner’s Manual 23 Maintenance and Service Maintenance and Service Indoor Unit Before performing any maintenance, turn off the main power to the system. Grille, Case, and Remote Control ❏ Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Supply power must be disconnected before cleaning th

  • LG Deluxe High Wall Mini Split, Maintenance and Service 24 Deluxe High Wall Mini Split 3 2 Air filter (Side) (Rear) Air outlet vents Air intake vents Piping 3 2 Air filter Triple Deodorizing Filter Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. NOTICE Replacement of Purifying Filter(Option) • Recomended use period : About 2 years 1. Open front panel and remove air filters. 4. Reinsert air filters

  • Owner’s Manual 25 ENGLISH Maintenance and Service Common Problems and Solutions Before calling for service, please review the following list of common problems and solutions. The air conditioner is operating normally when: • You hear a pinging noise. This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to

  • LG Deluxe High Wall Mini Split, 26 Deluxe High Wall Mini Split Maintenance and Service Troubleshooting The air conditioner may be operating abnormally when: Problem ■ The air conditioner is unplugged. ■ The fuse is blown/circuit breaker is tripped. ■ Power failure. ■ Airflow is restricted. ■ The air filter is dirty. ■ The room may have been hot. ■ Cold air is escaping. ■ Cooling coils have iced up. Air conditioner does not start Air conditioner does not cool as it should • Make sure the air conditioner plug is pushed completely into the outlet. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. • If power failure occurs, turn the

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Daxten RK-1 Specifications daxten/rk-1-69Q.pdf 08 Jun 2023 2 0.88 Mb
2 IBM 09-0572-000 Operation & user’s manual ibm/09-0572-000-Y68.pdf 25 Sep 2023 101
3 Clarion AB243R Owner's manual clarion/ab243r-79J.pdf 31 Jul 2023 82 1.56 Mb
4 ATIKA BIOTEC 1600 - Operating manual atika/biotec-1600-S85.pdf 05 Jan 2024 61 3.76 Mb
5 Craftsman 113.196120 Owner's manual craftsman/113-196120-2T1.pdf 30 Jan 2023 80 4.07 Mb
6 ProForm GR 80 831.21521.0 Operation & user’s manual proform/gr-80-831-21521-0-656.pdf 24 Apr 2023 16

Similar Resources:

  • Frick

    AGHN

    (22 pages)
    This manual contains rigging, assembly, start-up, and maintenance instructions. Read thoroughly before beginning installation. Failure to follow these instructions may result in personal injury or death, damage to the unit, or improper operation.EVAPORATORS AND AIR COOLERSAGHN/AXGHN, MANP/MXANP, MDAN/MDXAN, AGBF, GHN, MDN, and GGHNCheck www.FrickCold.com for …
  • Toshiba

    RAV-SM404ATP-E (TR)

    (101 pages)
    SERVICE MANUALOUTDOOR UNIT<DIGITAL INVERTER>RAV-SM304ATP-E (TR) RAV-SM404ATP-E (TR) RAV-SM304ATJP-E RAV-SM404ATJP-EAIR-CONDITIONER(SPLIT TYPE)FILE NO. SVM-14059SVM-13072.indb 1SVM-13072.indb 1 11/01/13 1:53 PM11/01/13 1:53 PM …
  • Daikin

    FH(Y)B35FV1

    (15 pages)
    SPLIT SYSTEM Air ConditionerOPERATION MANUALMODELS(Ceiling-mounted cassette built-in type)FH(Y)B35FV1 FHYB71FVALFH(Y)B45FV1 FHYB100FVALFH(Y)B60FV1 FHYB125FVALFHYB71FV1FHYB100FV1FHYB125FV1EnglishEspañolPortugues00_CV_3P170549-1_01.fm Page 1 Friday, November 25, 2005 5:52 PM …
  • Multi aqua

    MHQWW-09-H-1-U

    (24 pages)
    Multi TMMulti aquaInstruction M anualInstallation & O peration Please r ead t his m anual c arefully before o perating th e unit.WALL-MOUNTED F AN COIL UNIT Tel.: (864)850-8990 Fax: (864)850-8995 e-mail: s [email protected] aquaMHQWW-xx-H-1-U 208V-230V-50/60HzAIR C ONDITIONERwww.multiaqua.comMULTIAQUA, INC.306 Hagood St …
  • American Standard

    AccuLink 4A7A6048C1000B

    (12 pages)
    4A7A6048-SF-1KAccuLink™ SystemCooling4A7A6048C1000B4A7A6048C1000B230/1/602845DURATIONTM - SCROLL1 - 2230/1/6021.2 - 96NOYESNOPROPELLER27.6 - 1DIRECT - 14600/4600 1 - 1/5820200/230/1/601.10SPINE FIN™1 - 2427.815/16N/AR-410A7 LBS.- 8 OZ.YES7/83/8See Charging Chart (page 3)H X W X D46.4 X 35.1 X 38.727824220’30’40’50’60’7/8”7/8”7/8”7/8� …
  • LG

    Duct series

    (14 pages)
    P/N9373117049OPERATING MANUALKEEP THIS MANUALFOR FUTURE REFERENCEOPERATING MANUALBEDIENUNGSANLEITUNGMODE D’EMPLOIMANUAL DE FUNCIONAMIENTOMANUALE DI ISTRUZIONIΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣMANUAL DE INSTRUÇÕESEnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsAIR CONDITIONERDUCT TYPESUMOTUWETH FRSAAMPM36912 15 18 219373117049_cover …

Comments, Questions and Opinions: