Text of KingShield ASIM VST-IS598IH User Guide:

  • SAFETY INFORMATION SMOKE ALARM PLACEMENT Thank you for purchasing a KingShield Smoke Alarm from GreenBrook Electrical. This product should be installed by a competent person and in accordance with the current IEE Wiring Regulations. If in doubt, consult a qualified electrician. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE ALARM FEATURES Ionization smoke alarms are generally more effecti

  • KingShield ASIM VST-IS598IH, INTER-CONNECTING YOUR SMOKE ALARMS 2. Install a minimum of two smoke alarms in every home, no matter how s mall the home. 3. Install a smoke alarm in each room that is divided by a partial wall either c oming down from the ceiling at least 8 inches, or coming up from the floor. 4. Install a smoke alarm in lived-in attics o r attics which house electrical equipment like fires, air conditioners or heaters. DO NOT INSTALL SMOKE ALARMS - 1. Near appliances or areas where normal combustion regularly occurs such as kitchens, near

  • KingShield ASIM VST-IS598IH, TESTING HUSH FEATURE Test the alarm to be sure it is installed c orrectly and operating properly. The push to test button accurately tests the functions. Do not use an open flame to test this smoke alarm. You may ignite a nd damage the smoke alarm or your home. When testing, stand at arms length away from the alarm as the horn is very loud a nd can be harmful to your hearing. 1. Firmly press the PUSH-TO-TEST button for at least 5 seconds. The alarm will sound a loud beeping noise. This will end when

  • KingShield ASIM VST-IS598IH, O ur range of Alarms - Mains Ionisation Smoke Alarm Model: ASIM Mains Photoelectric Smoke Alarm Model: ASPM Mains Heat Alarm Model: AHPM Your KingShield Smoke Alarm is guaranteed for 5 years from the date of purchase. This does not affect your statutory rights. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE Issue no: 703304 Operating Temp: 4°C to 38°C Electrical Rating: 220-240V AC 50Hz & 9V Alkaline Battery Backup Battery Backup: In event of a power loss the battery will give operation

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Panasonic KX-TG3021 Operating instructions manual panasonic/kx-tg3021-55W.pdf 06 Jan 2024 12
2 Sony TRINITRON AA-2U Service manual sony/trinitron-aa-2u-6PK.pdf 17 Jan 2024 11 0.27 Mb
3 Pheonix Kiosks MT107KSK Operation & user’s manual pheonix/kiosks-mt107ksk-DUI.pdf 18 Oct 2023 3
4 Kingspan BF BIODISC Installation manuallines kingspan/bf-biodisc-XW3.pdf 20 Nov 2023 10
5 Xerox WorkCentre 5845 User information xerox/workcentre-5845-QI3.pdf 06 Mar 2023 83
6 LG GU292 Operation & user’s manual lg/gu292-373.pdf 09 Nov 2023 242

Similar Resources:

  • Fire-Lite

    MS-2410BC

    (64 pages)
    MS-2410BC ConventionalFire Alarm Control Panel Programming, Installation, Maintenance and Operating Instruction Manual24 Viceroy RoadUnit #6 & 7Concord, Ontario L4K2L9 Phone (905) 660-7210 FAX: (905) 660-7204 P/N 50801:B ECN 98-380BDocument #50801 8/17/98 Rev.© 1998 Fire� …
  • First Alert

    ONELINK

    (7 pages)
    Printed in MexicoM08-0149-002 Q05/06IMPORTANT! PLEASE READ CAREFULLY AND SAVE.This user’s manual contains important information about your Smoke Alarm’s operation. If you are installing this Smoke Alarm for use byothers, you must leave this manual—or a copy of it—with the end user.© 2006 BRK Brands, Inc. All Rights Reserved.BRK Brands, Inc., 3901 …
  • Ei Electronics

    RadioLINK Ei 407

    (2 pages)
    1. INTRODUCTIONPressing on the Ei407 Manual Call Point (MCP) black spot causes allthe RadioLINK Alarms to sound. This informs the occupants that thebuilding must be evacuated.The Ei 407 MCP also provides a means to test the RadioLink alarmswithout having to reach up to the smoke alarms on the ceilings as itcan be reset with the plastic key (supplied).We su …
  • Siemens

    5TC1292-7

    (2 pages)
    -4- -5-Low baery modeWhen the baery is running low, the smoke alarm will indicate this with a repeve beep and flash for approximately 30 days. WARNING: This smoke alarm is equipped with a non-replaceable baery. When this warning occurs, replace the device as soon as possible! The acousc low baery warning signal can be muted for ten hour …
  • Sentek

    SD-218-A Series

    (4 pages)
    SINGLE MULTIPLE STATION PHOTOELETRIC SMOKE DETECTOR SD-218 SERIES USER’S MANUAL TABLE OF CONTENTS INTRODUCTION………………………………..……………………………1 LOCATIONS TO INSTALL YOUR SMOKE DETECTOR …………………...1 LOCATIONS TO INSTALL YOUR SMOKE DETECTORS IN MOBILE HOMES AND RVs…………………………… …
  • LST

    B401RM

    (1 pages)
    © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDB401RM_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.Detector Base Series 300B401RMDescriptionSpecifi cationsThe Detector Base B401RM is designed for the easy con …