Installation & Service Instructions83-949-000SB1 & SB2Filter / Regulator SeriesISSUED: January, 2003Supersedes: September, 2001Doc.# 83-949-000, ECN# 020674, Rev. 2!! WARNINGTo avoid unpredictable system behavior that can cause personal injuryand property damage:• Disconnect electrical supply (when necessary) before installation,servicing, or con …
PUSHTOCLOSEPUSHTOOPENOUTLETDETAILOF PIVOTPINSELF-TAPPINGSCREWSINLETBODYPIVOTPINOUTLETBODYO-RINGO-RINGSHUTOFFBLADEINSTALLATION1. Refer to Warnings prior to installation.2. Install as close to the point of use as possible.3. Unit must be installed with the flow in the direction of the flow arrowon top of the body.4. Avoid using reducing bushings, couplings, et …
Installation & Service Instructions:83-955-0001/4" & 3/8"L12 Atomist LubricatorsISSUED: September, 2002Supersedes: November, 2001ECN020442, Rev.2!! WARNINGTo avoid unpredictable system behavior that can cause personalinjury and property damage:• Disconnect electrical supply (when necessary) before installation,servicing, or conversion.� …
MAINTENANCE1. EACH TIME THE BOWL IS CLEANED:A. Depressurize unit.B. Inspect seals and replace crazed, cracked, damaged ordeteriorated seals with original manufacturer's approvedseals only.2. Before placing unit in service, be sure that the bowl isreinstalled and securely locked in position.REPAIR KITSSight Gauge ......................................... …
Bowl guards are recommended for added protection of polycarbonate bowls where chemical attack may occasionally occur.! WARNINGTo avoid polycarbonate bowl rupture that can cause personal injury or property damage, do not exceed bowl pressure or temperature ratings. Polycarbonate bowls have a 150 PSIG pressure rating and a maximum temperature rating of 125°F. …
INSTALLATION1. Refer to Warnings.CAUTION! Depressurize Before Servicing!2. Install at air inlet or tool if possible. Unit will operate in any position,allowing it to be mounted on air hose.3. Install the unit with the air flowing in direction of arrow on body.4. MAKE SURE AIR SUPPLY IS TURNED OFF ANDDEPRESSURIZED BEFORE REMOVING FILL PLUG. Removefill plug a …